    <item>
      <title>AODD Pump Installation Guide — Step by Step</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:29:53 +0000</pubDate>
      <link>https://dev.to/antliapumps/aodd-pump-installation-guide-step-by-step-49me</link>
      <guid>https://dev.to/antliapumps/aodd-pump-installation-guide-step-by-step-49me</guid>
      <description>&lt;p&gt;A practical guide to installing and commissioning an AODD pump by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/practical-guide-to-installing-and-operating-an-aodd-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  Installation Steps
&lt;/h2&gt;

&lt;ol&gt;
&lt;li&gt;
&lt;strong&gt;Choose Location&lt;/strong&gt; — Close to fluid source, stable mounting&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Install FRL Unit&lt;/strong&gt; — Filter, Regulator, Lubricator on air inlet&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Connect Suction Line&lt;/strong&gt; — Same size as pump port, Teflon tape on threads&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Connect Discharge Line&lt;/strong&gt; — Avoid restrictions and sharp bends&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Connect Air Supply&lt;/strong&gt; — Via FRL unit, start at 2 kg/cm²&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Start Up&lt;/strong&gt; — Gradually increase pressure, check for leaks&lt;/li&gt;
&lt;/ol&gt;

&lt;h2&gt;
  
  
  Air Requirements
&lt;/h2&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Model&lt;/th&gt;
&lt;th&gt;Min SCFM&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;AOD 150&lt;/td&gt;
&lt;td&gt;8 SCFM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;AOD 300&lt;/td&gt;
&lt;td&gt;15 SCFM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;AOD 400&lt;/td&gt;
&lt;td&gt;25 SCFM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;AOD 500&lt;/td&gt;
&lt;td&gt;40 SCFM&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/practical-guide-to-installing-and-operating-an-aodd-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>AODD Pump Installation Guide — Step by Step</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:28:07 +0000</pubDate>
      <link>https://dev.to/antliapumps/aodd-pump-installation-guide-step-by-step-215h</link>
      <guid>https://dev.to/antliapumps/aodd-pump-installation-guide-step-by-step-215h</guid>
      <description>&lt;p&gt;Installation guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/practical-guide-to-installing-and-operating-an-aodd-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  Steps
&lt;/h2&gt;

&lt;ol&gt;
&lt;li&gt;Choose location — close to fluid source&lt;/li&gt;
&lt;li&gt;Install FRL unit on air inlet&lt;/li&gt;
&lt;li&gt;Connect suction line with Teflon tape&lt;/li&gt;
&lt;li&gt;Connect discharge line&lt;/li&gt;
&lt;li&gt;Start at 2 kg/cm², gradually increase&lt;/li&gt;
&lt;li&gt;Check all connections for leaks&lt;/li&gt;
&lt;/ol&gt;

&lt;h2&gt;
  
  
  Air Requirements
&lt;/h2&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Model&lt;/th&gt;
&lt;th&gt;Min SCFM&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;AOD 150&lt;/td&gt;
&lt;td&gt;8&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;AOD 300&lt;/td&gt;
&lt;td&gt;15&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;AOD 400&lt;/td&gt;
&lt;td&gt;25&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;AOD 500&lt;/td&gt;
&lt;td&gt;40&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/practical-guide-to-installing-and-operating-an-aodd-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>Types of Barrel Pumps and Their Applications</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:49 +0000</pubDate>
      <link>https://dev.to/antliapumps/types-of-barrel-pumps-and-their-applications-1kge</link>
      <guid>https://dev.to/antliapumps/types-of-barrel-pumps-and-their-applications-1kge</guid>
      <description>&lt;p&gt;Barrel pump guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/types-of-barrel-pumps-and-their-applications.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  Types
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;
&lt;strong&gt;Pneumatic:&lt;/strong&gt; Compressed air, safe for chemicals/flammables&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Electric:&lt;/strong&gt; Motor driven, oils/detergents/water&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Piston Type:&lt;/strong&gt; High viscosity fluids&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Rotary Hand:&lt;/strong&gt; Manual, light duty&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;&lt;strong&gt;Buy:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/barrel-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>Benefits of FRL Unit for AODD Pumps</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:46 +0000</pubDate>
      <link>https://dev.to/antliapumps/benefits-of-frl-unit-for-aodd-pumps-nei</link>
      <guid>https://dev.to/antliapumps/benefits-of-frl-unit-for-aodd-pumps-nei</guid>
      <description>&lt;p&gt;FRL unit guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/benefits-of-FRL-unit.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  What is FRL?
&lt;/h2&gt;

&lt;p&gt;Filter + Regulator + Lubricator&lt;/p&gt;

&lt;ul&gt;
&lt;li&gt;
&lt;strong&gt;Filter:&lt;/strong&gt; Removes moisture and particles&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Regulator:&lt;/strong&gt; Controls air pressure, enables precise flow control&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Lubricator:&lt;/strong&gt; Adds oil mist, lubricates air valve&lt;/li&gt;
&lt;/ul&gt;

&lt;h2&gt;
  
  
  Benefits
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;Extends diaphragm life 2-3x&lt;/li&gt;
&lt;li&gt;Prevents stalling&lt;/li&gt;
&lt;li&gt;Reduces maintenance&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/benefits-of-FRL-unit.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>Role of Diaphragm in AODD Pump — Material Selection</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:45 +0000</pubDate>
      <link>https://dev.to/antliapumps/role-of-diaphragm-in-aodd-pump-material-selection-5fdg</link>
      <guid>https://dev.to/antliapumps/role-of-diaphragm-in-aodd-pump-material-selection-5fdg</guid>
      <description>&lt;p&gt;Diaphragm guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/role-of-diaphragm-in-AODD-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  Diaphragm Materials
&lt;/h2&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Material&lt;/th&gt;
&lt;th&gt;Best For&lt;/th&gt;
&lt;th&gt;Max Temp&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;PTFE&lt;/td&gt;
&lt;td&gt;Aggressive chemicals, pharma&lt;/td&gt;
&lt;td&gt;120°C&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Santoprene&lt;/td&gt;
&lt;td&gt;General industrial&lt;/td&gt;
&lt;td&gt;104.4°C&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Buna-N&lt;/td&gt;
&lt;td&gt;Oils, petroleum&lt;/td&gt;
&lt;td&gt;80°C&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Viton&lt;/td&gt;
&lt;td&gt;Solvents, hydrocarbons&lt;/td&gt;
&lt;td&gt;150°C&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Neoprene&lt;/td&gt;
&lt;td&gt;General chemicals&lt;/td&gt;
&lt;td&gt;80°C&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/role-of-diaphragm-in-AODD-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>3 FAQs About Pulsation Dampeners for AODD Pumps</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:44 +0000</pubDate>
      <link>https://dev.to/antliapumps/3-faqs-about-pulsation-dampeners-for-aodd-pumps-41k6</link>
      <guid>https://dev.to/antliapumps/3-faqs-about-pulsation-dampeners-for-aodd-pumps-41k6</guid>
      <description>&lt;p&gt;Pulsation dampener guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/3-faqs-about-pulsation-dampeners.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  FAQ 1: What is a pulsation dampener?
&lt;/h2&gt;

&lt;p&gt;Reduces flow fluctuations from AODD pump reciprocating action for smoother output.&lt;/p&gt;

&lt;h2&gt;
  
  
  FAQ 2: When do I need one?
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;Spray applications&lt;/li&gt;
&lt;li&gt;Metering/dosing&lt;/li&gt;
&lt;li&gt;Flow meter installations&lt;/li&gt;
&lt;li&gt;When piping vibration is a problem&lt;/li&gt;
&lt;/ul&gt;

&lt;h2&gt;
  
  
  FAQ 3: Types?
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;Air chamber type&lt;/li&gt;
&lt;li&gt;Bladder type (more effective)&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/3-faqs-about-pulsation-dampeners.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>DO's and DON'Ts of AODD Pump — Best Practices</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:41 +0000</pubDate>
      <link>https://dev.to/antliapumps/dos-and-donts-of-aodd-pump-best-practices-3bfn</link>
      <guid>https://dev.to/antliapumps/dos-and-donts-of-aodd-pump-best-practices-3bfn</guid>
      <description>&lt;p&gt;Best practices by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/dos-and-donts-aodd-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  ✅ DO's
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;Install FRL unit&lt;/li&gt;
&lt;li&gt;Start at low pressure (2 kg/cm²)&lt;/li&gt;
&lt;li&gt;Use correct diaphragm material&lt;/li&gt;
&lt;li&gt;Flush pump after every use&lt;/li&gt;
&lt;li&gt;Install strainer for abrasive fluids&lt;/li&gt;
&lt;/ul&gt;

&lt;h2&gt;
  
  
  ❌ DON'Ts
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;Run dry for extended periods&lt;/li&gt;
&lt;li&gt;Exceed 6 kg/cm² air pressure&lt;/li&gt;
&lt;li&gt;Leave fluid inside pump&lt;/li&gt;
&lt;li&gt;Ignore air exhaust leaks&lt;/li&gt;
&lt;li&gt;Skip maintenance&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/dos-and-donts-aodd-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>AODD Pump for Highly Viscous Material Transfer</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:38 +0000</pubDate>
      <link>https://dev.to/antliapumps/aodd-pump-for-highly-viscous-material-transfer-4nod</link>
      <guid>https://dev.to/antliapumps/aodd-pump-for-highly-viscous-material-transfer-4nod</guid>
      <description>&lt;p&gt;Viscous fluid guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/aodd-pump-highly-viscous-material.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  Why AODD Works for Viscous Fluids
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;Large ball valves handle thick fluids&lt;/li&gt;
&lt;li&gt;Gentle pumping — no shear damage&lt;/li&gt;
&lt;li&gt;Variable speed control&lt;/li&gt;
&lt;li&gt;Self-priming even with high viscosity&lt;/li&gt;
&lt;/ul&gt;

&lt;h2&gt;
  
  
  Viscosity Range
&lt;/h2&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Viscosity&lt;/th&gt;
&lt;th&gt;Model&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Up to 5000 CPS&lt;/td&gt;
&lt;td&gt;AOD 300+&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Up to 12000 CPS&lt;/td&gt;
&lt;td&gt;AOD 400/500&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;h2&gt;
  
  
  Applications
&lt;/h2&gt;

&lt;p&gt;Starch, gum, cream, printing inks, resins, food purees&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/aodd-pump-highly-viscous-material.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>AODD Pump Industrial Uses and Applications</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:37 +0000</pubDate>
      <link>https://dev.to/antliapumps/aodd-pump-industrial-uses-and-applications-3944</link>
      <guid>https://dev.to/antliapumps/aodd-pump-industrial-uses-and-applications-3944</guid>
      <description>&lt;p&gt;Application guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/aodd-pump-industrial-uses-and-application.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  Industries
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;
&lt;strong&gt;Chemical:&lt;/strong&gt; Acids, alkalis, solvents safely without electricity&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Pharmaceutical:&lt;/strong&gt; FDA-compliant SS316 for API, solvents&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Food &amp;amp; Beverage:&lt;/strong&gt; SS316 for juice, dairy, sauces&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Printing:&lt;/strong&gt; Ink circulation, varnish transfer&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Paint &amp;amp; Coatings:&lt;/strong&gt; Transfer, spray, viscous coatings&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Mining:&lt;/strong&gt; Slurry transfer, acid mine drainage&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Wastewater:&lt;/strong&gt; Sludge, chemical dosing&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;EV Battery:&lt;/strong&gt; Electrolyte, KOH/acid handling&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/aodd-pump-industrial-uses-and-application.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>10 Frequently Asked Questions About Diaphragm Pumps</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:35 +0000</pubDate>
      <link>https://dev.to/antliapumps/10-frequently-asked-questions-about-diaphragm-pumps-45kk</link>
      <guid>https://dev.to/antliapumps/10-frequently-asked-questions-about-diaphragm-pumps-45kk</guid>
      <description>&lt;p&gt;FAQ guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/10-frequently-asked-questions-about-diaphragm-pumps.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  Top FAQs
&lt;/h2&gt;

&lt;p&gt;&lt;strong&gt;Q: What is an AODD pump?&lt;/strong&gt; Air Operated Double Diaphragm pump — uses compressed air, no electricity.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Q: Can AODD pump run dry?&lt;/strong&gt; Yes, AODD pumps can run dry without damage.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Q: What fluids can AODD handle?&lt;/strong&gt; Water, oils, acids, alkalis, solvents, slurries, food, pharma, viscous fluids up to 12000 CPS.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Q: What air pressure is needed?&lt;/strong&gt; 2–6 kg/cm² at 8–80 SCFM depending on model.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Q: How long do diaphragms last?&lt;/strong&gt; 6–12 months with proper maintenance and correct material selection.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/10-frequently-asked-questions-about-diaphragm-pumps.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>Cleaning Air Assembly of AODD Pump — Maintenance Guide</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:34 +0000</pubDate>
      <link>https://dev.to/antliapumps/cleaning-air-assembly-of-aodd-pump-maintenance-guide-4h17</link>
      <guid>https://dev.to/antliapumps/cleaning-air-assembly-of-aodd-pump-maintenance-guide-4h17</guid>
      <description>&lt;p&gt;Maintenance guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/cleaning-air-assembly-aodd-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  Steps to Clean Air Assembly
&lt;/h2&gt;

&lt;ol&gt;
&lt;li&gt;Depressurise — shut off air supply, release pressure&lt;/li&gt;
&lt;li&gt;Remove air valve cover&lt;/li&gt;
&lt;li&gt;Remove and inspect spool valve&lt;/li&gt;
&lt;li&gt;Clean with dry cloth — no solvents on rubber parts&lt;/li&gt;
&lt;li&gt;Check O-rings — replace if cracked or swollen&lt;/li&gt;
&lt;li&gt;Apply thin coat of SAE 40 oil&lt;/li&gt;
&lt;li&gt;Reassemble and test at low pressure&lt;/li&gt;
&lt;/ol&gt;

&lt;h2&gt;
  
  
  Signs Air Assembly Needs Cleaning
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;Pump stalling mid-stroke&lt;/li&gt;
&lt;li&gt;Irregular cycling rhythm&lt;/li&gt;
&lt;li&gt;Reduced flow at same pressure&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/cleaning-air-assembly-aodd-pump.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>
      <category>manufacturing</category>
      <category>engineering</category>
      <category>industrial</category>
      <category>india</category>
    </item>
    <item>
      <title>AODD Pump Performance Curve — How to Read It</title>
      <dc:creator>Antlia Engineering Works</dc:creator>
      <pubDate>Sun, 24 May 2026 06:27:33 +0000</pubDate>
      <link>https://dev.to/antliapumps/aodd-pump-performance-curve-how-to-read-it-18dj</link>
      <guid>https://dev.to/antliapumps/aodd-pump-performance-curve-how-to-read-it-18dj</guid>
      <description>&lt;p&gt;Performance curve guide by &lt;strong&gt;Antlia Engineering Works&lt;/strong&gt; — Mumbai, India.&lt;/p&gt;

&lt;p&gt;📞 +91 9819395995 | 🌐 &lt;a href="https://www.antliaworks.com/reading-the-air-operated-double-diaphragm-pump-performance-curve.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

&lt;h2&gt;
  
  
  What the Curve Shows
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;X-axis: Flow rate (LPM or GPM)&lt;/li&gt;
&lt;li&gt;Y-axis: Discharge pressure (bar or psi)&lt;/li&gt;
&lt;li&gt;Multiple lines: Each for a different inlet air pressure&lt;/li&gt;
&lt;/ul&gt;

&lt;h2&gt;
  
  
  How to Use It
&lt;/h2&gt;

&lt;ol&gt;
&lt;li&gt;Know your required flow rate&lt;/li&gt;
&lt;li&gt;Know your discharge pressure&lt;/li&gt;
&lt;li&gt;Find the intersection on the curve&lt;/li&gt;
&lt;li&gt;Read off required air pressure and SCFM&lt;/li&gt;
&lt;/ol&gt;

&lt;h2&gt;
  
  
  Key Points
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;Higher air pressure = higher flow and higher discharge pressure&lt;/li&gt;
&lt;li&gt;Flow decreases as back pressure increases&lt;/li&gt;
&lt;li&gt;SCFM requirement increases with flow rate&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;&lt;strong&gt;Full guide:&lt;/strong&gt; &lt;a href="https://www.antliaworks.com/reading-the-air-operated-double-diaphragm-pump-performance-curve.html" rel="noopener noreferrer"&gt;antliaworks.com&lt;/a&gt;&lt;/p&gt;

</description>