<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <channel>
    <title>DEV Community: Desmond Gilmour</title>
    <description>The latest articles on DEV Community by Desmond Gilmour (@dessygil).</description>
    <link>https://dev.to/dessygil</link>
    <image>
      <url>https://media2.dev.to/dynamic/image/width=90,height=90,fit=cover,gravity=auto,format=auto/https:%2F%2Fdev-to-uploads.s3.us-east-2.amazonaws.com%2Fuploads%2Fuser%2Fprofile_image%2F1001318%2F27491975-c689-4a6e-b76b-cd60ba741d8b.JPEG</url>
      <title>DEV Community: Desmond Gilmour</title>
      <link>https://dev.to/dessygil</link>
    </image>
    <atom:link rel="self" type="application/rss+xml" href="https://dev.to/feed/dessygil"/>
    <language>en</language>
    <item>
      <title>Your bispecific gained an acidic peak. Does it still bind both targets?</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Wed, 25 Nov 2026 22:26:13 +0000</pubDate>
      <link>https://dev.to/dessygil/your-bispecific-gained-an-acidic-peak-does-it-still-bind-both-targets-3n87</link>
      <guid>https://dev.to/dessygil/your-bispecific-gained-an-acidic-peak-does-it-still-bind-both-targets-3n87</guid>
      <description>&lt;p&gt;Say a new manufacturing lot comes back with a larger acidic peak. The unfractionated antibody still binds about as well as the reference. Would you move on?&lt;/p&gt;

&lt;p&gt;I’d collect that peak and test both arms separately. In a Bio-Techne and Nicoya application note on the CD20 × CD3 bispecific mosunetuzumab, two unfractionated samples had nearly identical CD20 affinities. Yet within the research-grade comparison material, the acidic fraction had a &lt;strong&gt;&lt;a href="https://nicoyalife.com/wp-content/uploads/2026/02/A-Novel-icIEF-SPR-Workflow-for-Correlating-the-Charge-Structure-to-the-Function-of-a-Bispecific-Antibody.pdf#page=9" rel="noopener noreferrer"&gt;7.2-fold higher apparent CD20 K_D&lt;/a&gt;&lt;/strong&gt; than its own main fraction. Its CD3 affinity was close to the main fraction’s. If I’d only run the bulk sample or checked the CD3 arm, I would have missed the difference.&lt;/p&gt;

&lt;h2&gt;
  
  
  Why Alto is a good match for MauriceFlex
&lt;/h2&gt;

&lt;p&gt;Bio-Techne’s &lt;strong&gt;&lt;a href="https://www.bio-techne.com/instruments/ice/mauriceflex" rel="noopener noreferrer"&gt;MauriceFlex&lt;/a&gt;&lt;/strong&gt; uses imaged capillary isoelectric focusing (icIEF) to separate proteins by their isoelectric point, or pI. That’s the pH at which a protein has no net charge. An acidic peak focuses at a lower pH than the main peak. MauriceFlex can collect the material behind those peaks in a 96-well plate, so you can take the acidic and main fractions into the next assay.&lt;/p&gt;

&lt;p&gt;The two systems work with small volumes at different points in the workflow. Bio-Techne specifies &lt;a href="https://www.bio-techne.com/pdf-download-arena-document/datasheet/pl8-0009/21" rel="noopener noreferrer"&gt;100 µL of prepared sample as the minimum for MauriceFlex fractionation&lt;/a&gt;. Once you’ve collected a fraction, &lt;strong&gt;&lt;a href="https://nicoyalife.com/alto/" rel="noopener noreferrer"&gt;Alto Digital SPR&lt;/a&gt;&lt;/strong&gt; uses surface plasmon resonance (SPR) to follow how quickly it binds and how quickly the complex comes apart. In the mosunetuzumab study, the team loaded &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/02/A-Novel-icIEF-SPR-Workflow-for-Correlating-the-Charge-Structure-to-the-Function-of-a-Bispecific-Antibody.pdf#page=3" rel="noopener noreferrer"&gt;2 µL of each prepared antibody fraction for the CD3 assay&lt;/a&gt;. A 2 µL load is useful when I want binding curves from a fraction and still need material for a repeat or mass spec. The authors &lt;a href="https://resources.bio-techne.com/bio-techne-assets/docs/literature/7678776428-icIEF-fractionation-and-SPR-workflow.pdf#page=4" rel="noopener noreferrer"&gt;pooled and concentrated fractions from four runs per material&lt;/a&gt;, so I’d check recovery and concentration before allocating the sample.&lt;/p&gt;

&lt;p&gt;Once the fractions are prepared, the transfer is a pipetting step. Load an aliquot onto the &lt;a href="https://nicoyalife.com/alto/" rel="noopener noreferrer"&gt;disposable Alto cartridge&lt;/a&gt;, and Alto handles the serial dilutions. For CD3, it made five concentrations of the antibody fraction. For CD20, the team captured the antibody and Alto made &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/02/A-Novel-icIEF-SPR-Workflow-for-Correlating-the-Charge-Structure-to-the-Function-of-a-Bispecific-Antibody.pdf#page=4" rel="noopener noreferrer"&gt;five concentrations of the antigen&lt;/a&gt;. That saves a round of manual dilution for each series. The liquid handling is contained in the cartridge, which you remove at the end of the run.&lt;/p&gt;

&lt;p&gt;I can picture the pairing on a shared bench, too. &lt;a href="https://www.bio-techne.com/instruments/ice/mauriceflex" rel="noopener noreferrer"&gt;MauriceFlex is 42 cm wide by 61 cm deep&lt;/a&gt;, and &lt;a href="https://nicoyalife.com/wp-content/uploads/2023/02/Alto-Digital-SPR-Brochure.pdf#page=7" rel="noopener noreferrer"&gt;Alto is 35 cm wide by 52 cm deep&lt;/a&gt; in Nicoya’s technical brochure. The two instrument bodies add up to about &lt;strong&gt;77 cm (30 in) of width&lt;/strong&gt; side by side. I’d allow extra room for the workstation, ventilation, and access to both instruments.&lt;/p&gt;

&lt;h2&gt;
  
  
  The CD20 difference only showed up after fractionation
&lt;/h2&gt;

&lt;p&gt;These are the &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/02/A-Novel-icIEF-SPR-Workflow-for-Correlating-the-Charge-Structure-to-the-Function-of-a-Bispecific-Antibody.pdf#page=9" rel="noopener noreferrer"&gt;reported apparent dissociation constants&lt;/a&gt;, or K_D values. Within the same assay, a higher K_D indicates weaker apparent binding. The authors describe the comparison material as a research-grade biosimilar.&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Sample&lt;/th&gt;
&lt;th&gt;CD3 epsilon K_D&lt;/th&gt;
&lt;th&gt;CD20 nanodisc K_D&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Reference mosunetuzumab, unfractionated&lt;/td&gt;
&lt;td&gt;28.6 nM&lt;/td&gt;
&lt;td&gt;12.9 nM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Research-grade comparison, unfractionated&lt;/td&gt;
&lt;td&gt;22.8 nM&lt;/td&gt;
&lt;td&gt;13.4 nM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Research-grade comparison, main fraction&lt;/td&gt;
&lt;td&gt;14.7 nM&lt;/td&gt;
&lt;td&gt;22.4 nM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Research-grade comparison, acidic fraction&lt;/td&gt;
&lt;td&gt;12.9 nM&lt;/td&gt;
&lt;td&gt;162 nM&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;The assay setup mattered. The team immobilized CD3 epsilon on the sensor and flowed the antibody fractions over it. For CD20, they captured the antibodies by their Fc region and flowed full-length CD20 carried in a nanodisc, a tiny patch of lipid membrane. The recombinant CD20 extracellular construct they tried &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/02/A-Novel-icIEF-SPR-Workflow-for-Correlating-the-Charge-Structure-to-the-Function-of-a-Bispecific-Antibody.pdf#page=5" rel="noopener noreferrer"&gt;gave no appreciable binding in their screen&lt;/a&gt;. If an arm looks weak, I’d check how the antigen was presented before blaming the antibody.&lt;/p&gt;

&lt;h2&gt;
  
  
  What I’d do with a growing acidic peak
&lt;/h2&gt;

&lt;ol&gt;
&lt;li&gt;
&lt;strong&gt;Collect the acidic and main fractions and keep a bulk control.&lt;/strong&gt; I’d confirm that the fractions still map to the expected peaks and check how much antibody I recovered before splitting the material between assays.&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Measure each arm and look at the curves.&lt;/strong&gt; I’d compare the fractions within each target assay. For CD20, I’d check how much antibody each sensor captured. I’d also look at the reference and blank signals, and repeat a meaningful difference with independently collected material. For more on reading the curves, see &lt;a href="https://desmondgilmour.ca/writing/your-antibody-barely-dissociates-how-much-can-you-trust-the-off-rate-34ba" rel="noopener noreferrer"&gt;how much can you trust the off-rate?&lt;/a&gt;
&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Match the next test to the decision.&lt;/strong&gt; For molecular identity, I’d send an aliquot to liquid chromatography–mass spectrometry (LC–MS). If I need to know whether the same molecule can engage both targets at once, I’d use a &lt;a href="https://pubmed.ncbi.nlm.nih.gov/27721070/" rel="noopener noreferrer"&gt;bridging assay designed for that question&lt;/a&gt;. If the decision is about potency, I’d use a &lt;a href="https://www.accessdata.fda.gov/drugsatfda_docs/nda/2023/761263Orig1s000ChemR.pdf#page=48" rel="noopener noreferrer"&gt;cell-based assay tied to how the antibody works&lt;/a&gt;. The two separate SPR assays in this note establish binding to each target at the fraction level.&lt;/li&gt;
&lt;/ol&gt;

&lt;p&gt;The mass spec follow-up is especially interesting here. In a &lt;a href="https://resources.bio-techne.com/bio-techne-assets/docs/literature/app-note-maurice-flex-genovis-comparing-charge-variants.pdf#page=7" rel="noopener noreferrer"&gt;companion LC–MS study&lt;/a&gt;, Bio-Techne and Genovis found correctly paired antibodies and antibodies with mismatched light chains in the acidic comparison fractions. That gives you a lead to investigate. The 162 nM value describes a mixed fraction, so it can’t tell you the affinity of the mismatched species on its own.&lt;/p&gt;

&lt;p&gt;An acidic peak can also turn out to have little effect in the assays you care about. &lt;a href="https://pubmed.ncbi.nlm.nih.gov/41996728/" rel="noopener noreferrer"&gt;Wu and colleagues&lt;/a&gt; reported a bispecific with an unexpected disulfide bond and comparable binding and potency in its acidic and main peaks. &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC11926628/" rel="noopener noreferrer"&gt;Nguyen and colleagues&lt;/a&gt; found reduced cell-based potency in some acidic fractions of other anti-CD3 bispecifics. I touched on the limits of a reassuring bulk result in my piece on &lt;a href="https://desmondgilmour.ca/writing/the-antibody-still-binds-what-changed-when-you-added-the-payload-3h4e" rel="noopener noreferrer"&gt;what changed when you added the payload&lt;/a&gt;. Here, testing the fractions showed exactly which interaction deserved a closer look.&lt;/p&gt;

&lt;h2&gt;
  
  
  Give the peak a follow-up experiment
&lt;/h2&gt;

&lt;p&gt;If I already had MauriceFlex, I’d pair it with Alto so I could test both arms with small aliquots and keep material for whichever interaction needs a closer look. In this case, that would be CD20. If both arms still bind separately and the molecule is designed to bring two cells together, I’d test whether it can still do that. That’s the result I’d want in hand before deciding whether the peak belongs on a trend chart or at the top of the process investigation.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>biotech</category>
      <category>manufacturing</category>
      <category>science</category>
    </item>
    <item>
      <title>BLI or SPR for Automated Antibody Titer? Follow One Sample Before You Connect Either to a Bioreactor</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Mon, 23 Nov 2026 20:36:57 +0000</pubDate>
      <link>https://dev.to/dessygil/bli-or-spr-for-automated-antibody-titer-follow-one-sample-before-you-connect-either-to-a-bioreactor-ic7</link>
      <guid>https://dev.to/dessygil/bli-or-spr-for-automated-antibody-titer-follow-one-sample-before-you-connect-either-to-a-bioreactor-ic7</guid>
      <description>&lt;p&gt;You’re testing two feeding strategies. By the morning process meeting, you know how much glucose the cells consumed in each reactor. Can you also tell the team which vessel had the higher antibody titer?&lt;/p&gt;

&lt;p&gt;For that job, &lt;strong&gt;I’d choose Nicoya Alto&lt;/strong&gt;. What puts it first for me is the &lt;a href="https://nicoyalife.com/blog/balance-project-advances-autonomous-bioprocessing-with-alto-digital-spr/" rel="noopener noreferrer"&gt;BALANCE bioreactor project&lt;/a&gt;. The team showed how to get a sample out of a running bioreactor, measure antibody concentration directly in crude culture supernatant, and make the result available during the run. Nobody had to carry the sample to the instrument. If you want a titer from an overnight sample, that handoff matters.&lt;/p&gt;

&lt;h2&gt;
  
  
  Follow one sample through BALANCE
&lt;/h2&gt;

&lt;p&gt;At CPI, the BALANCE team ran fed-batch bioreactors producing a trastuzumab biosimilar candidate. Labman’s robot drew a sample, prepared it and delivered it to Alto. Alto ran antibody standards of known concentration, then measured the sample using digital surface plasmon resonance (SPR). The standards established how the binding signal changed with concentration. Alto used that curve to estimate the antibody titer in the supernatant, without an antibody purification step. The partners &lt;a href="https://nicoyalife.com/blog/balance-project-advances-autonomous-bioprocessing-with-alto-digital-spr/" rel="noopener noreferrer"&gt;evaluated the integrated approach at both 0.2 L and 10 L&lt;/a&gt;.&lt;/p&gt;

&lt;p&gt;What did the team actually do with the result? &lt;a href="https://www.basetwo.ai/applied-research-labs/autonomous-closed-loop-bioreactor-control" rel="noopener noreferrer"&gt;Basetwo’s technical report&lt;/a&gt; describes two measurements on different schedules. Its AI predicted glucose demand, and the controller updated the feed-pump setting every four hours. Alto measured antibody titer from the daily robotic samples. Those measurements let the scientists compare antibody concentrations under the two feeding strategies. Basetwo reports that the automatically fed cultures achieved a higher titer than the glucose-limited manual control.&lt;/p&gt;

&lt;h2&gt;
  
  
  Who carries the sample from the bioreactor to Octet?
&lt;/h2&gt;

&lt;p&gt;Sartorius reports that the &lt;a href="https://www.sartorius.com/en/products/biolayer-interferometry/octet-automation" rel="noopener noreferrer"&gt;Octet RH96 can quantify 96 wells in as little as two minutes&lt;/a&gt;. If full plates are backing up in your lab, that figure belongs in your buying decision. Sartorius also documents &lt;a href="https://www.sartorius.com/en/products/biolayer-interferometry/biosensors-kits/protein-a-proa-biosensors" rel="noopener noreferrer"&gt;direct IgG quantitation in crude culture supernatant&lt;/a&gt; using its Protein A biosensors.&lt;/p&gt;

&lt;p&gt;If I were choosing a system for unattended monitoring, I’d ask who carries the sample. Sartorius documents an &lt;a href="https://www.sartorius.com/en/products/fermentation-bioreactors/ambr-multi-parallel-bioreactors/ambr-analyzer" rel="noopener noreferrer"&gt;Ambr–Octet configuration&lt;/a&gt; that sends sample information to Octet and returns results to Ambr electronically. In that configuration, a person transports the sample between instruments. Sartorius also offers &lt;a href="https://www.sartorius.com/en/products/biolayer-interferometry/octet-automation" rel="noopener noreferrer"&gt;robotic Octet workcells&lt;/a&gt;, so I’d ask which physical transfers are included in the setup being quoted.&lt;/p&gt;

&lt;h2&gt;
  
  
  Check the titer where it could change your decision
&lt;/h2&gt;

&lt;p&gt;One thing I like about Alto is that it can &lt;a href="https://nicoyalife.com/alto/" rel="noopener noreferrer"&gt;prepare serial dilutions on the disposable cartridge&lt;/a&gt;. That takes a repetitive pipetting step off the liquid handler. The more interesting question is how well the resulting calibration curve serves the decision you’re making.&lt;/p&gt;

&lt;p&gt;In a separate &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/01/Tech-Note-Quantifying-monoclonal-antibodies-in-serum.pdf" rel="noopener noreferrer"&gt;Nicoya study using antibody spiked into rabbit serum&lt;/a&gt;, Alto used a ten-point calibration curve. Table 1 lists &lt;strong&gt;3 µL for each unknown shown&lt;/strong&gt;. A 32 nM spike measured 30.98 nM, about 3% low. A 2 nM spike measured 1.74 nM, 13% low. If I were using an early titer measurement to decide which clones to keep, I’d want to see that same check near my cutoff, in my own culture medium.&lt;/p&gt;

&lt;p&gt;That’s how I’d set up a comparison in the lab:&lt;/p&gt;

&lt;ol&gt;
&lt;li&gt;
&lt;strong&gt;Split early-, mid- and late-run samples.&lt;/strong&gt; Run each on the proposed system and with your current titer method. Include a sample near a cutoff you actually use. Decide beforehand how much disagreement would change which clone or condition you advance.&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Include a sample above the calibration range.&lt;/strong&gt; See how the system flags it, what triggers a dilution and rerun, and whether the final result accounts for that dilution.&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Follow one unattended draw all the way through.&lt;/strong&gt; Record the total volume taken from the vessel, including what the sampler and liquid handler require. Check that the titer arrives in your software with the correct vessel ID and collection time.&lt;/li&gt;
&lt;/ol&gt;

&lt;h2&gt;
  
  
  Why I’d choose Alto
&lt;/h2&gt;

&lt;p&gt;&lt;strong&gt;For a lab whose priority is getting a titer from a running bioreactor overnight, I’d choose Alto.&lt;/strong&gt; In BALANCE, Labman automated the physical transfer, and Alto handled calibration and quantitation directly in crude supernatant. That’s the part I’d want demonstrated before committing to an instrument. The partners didn’t publish a draw-to-result time, so I’d measure it with my own vessel, antibody and software.&lt;/p&gt;

&lt;p&gt;I’d start the clock when the sample leaves the reactor and stop it when the team can see a calibrated titer linked to the right vessel. If that result is ready when we sit down to choose which feeding strategy to carry forward, the system has done the job I bought it for.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>automation</category>
      <category>hardware</category>
      <category>science</category>
    </item>
    <item>
      <title>Why I’d Choose Chirascan Over JASCO for Antibody Lot Comparisons</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Mon, 23 Nov 2026 03:45:16 +0000</pubDate>
      <link>https://dev.to/dessygil/why-id-choose-chirascan-over-jasco-for-antibody-lot-comparisons-3hc9</link>
      <guid>https://dev.to/dessygil/why-id-choose-chirascan-over-jasco-for-antibody-lot-comparisons-3hc9</guid>
      <description>&lt;h1&gt;
  
  
  Why I’d Choose Chirascan Over JASCO for Antibody Lot Comparisons
&lt;/h1&gt;

&lt;p&gt;&lt;strong&gt;For an antibody lab that routinely measures both far- and near-UV circular dichroism (CD), I’d choose the Chirascan Q100.&lt;/strong&gt; It supports the two flow-cell lengths Samsung Bioepis used to compare an eculizumab biosimilar with its reference product. And when two lots look different, Chirascan’s software lets you trace that difference back to the measured curves.&lt;/p&gt;

&lt;h2&gt;
  
  
  Why 0.1 mm and 10 mm both matter
&lt;/h2&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Documented configuration&lt;/th&gt;
&lt;th&gt;Shortest flow cell listed for this configuration&lt;/th&gt;
&lt;th&gt;Longest flow cell listed for this configuration&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;a href="https://www.photophysics.com/media/yuldoawl/chirascan-q100-user-manual.pdf" rel="noopener noreferrer"&gt;Chirascan Q100&lt;/a&gt;&lt;/td&gt;
&lt;td&gt;&lt;strong&gt;0.1 mm&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;strong&gt;10 mm&lt;/strong&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;a href="https://www.jasco.ro/wp-content/uploads/2024/04/JASCO_HTCD-Plus_2024.pdf" rel="noopener noreferrer"&gt;JASCO HTCD Plus with JFLC-515 holder&lt;/a&gt;&lt;/td&gt;
&lt;td&gt;0.2 mm&lt;/td&gt;
&lt;td&gt;2 mm&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;In the far UV, the buffer can absorb so much light that you lose the part of the spectrum you care about. A &lt;strong&gt;0.1 mm flow cell&lt;/strong&gt; gives the light less buffer to pass through. That can let you measure the antibody in its formulation and keep the short-wavelength data that a longer cell would obscure.&lt;/p&gt;

&lt;p&gt;In the near UV, the challenge is often a weak signal from the folded antibody. A &lt;strong&gt;10 mm flow cell&lt;/strong&gt; gives the light a longer path through the protein solution, strengthening the CD signal at the same antibody concentration. That gives you a way to see more detail without first concentrating the protein.&lt;/p&gt;

&lt;p&gt;Samsung Bioepis used exactly those two pathlengths on a Q100 in its &lt;a href="https://link.springer.com/article/10.1007/s40259-023-00591-9" rel="noopener noreferrer"&gt;eculizumab biosimilar study&lt;/a&gt;. The team used 0.1 mm to compare secondary structure and 10 mm to compare features of the folded antibodies, recording triplicate scans. The &lt;a href="https://ostr.ccr.cancer.gov/cd-3/" rel="noopener noreferrer"&gt;National Cancer Institute’s biophysics facility&lt;/a&gt; also lists both lengths for its Q100 autosampler and recommends them for those measurements.&lt;/p&gt;

&lt;h2&gt;
  
  
  Why optical calibration matters when you compare peak heights
&lt;/h2&gt;

&lt;p&gt;Two lots can have peaks in the same places and still differ in the relative heights of those peaks. When that’s the difference you’re investigating, you want the instrument to report the CD signal accurately across the spectrum.&lt;/p&gt;

&lt;p&gt;Applied Photophysics engineers use &lt;a href="https://www.photophysics.com/product-pages/chirascan-q100/" rel="noopener noreferrer"&gt;optical calibration at multiple wavelengths&lt;/a&gt; during manufacture or service. The Q100 applies a wavelength-specific correction to the CD signal. That accounts for variation in the instrument’s response across the scan and gives you a sound basis for comparing band heights. Because the reference is optical, the accuracy of that calibration step doesn’t depend on someone preparing a solution at exactly the right concentration. &lt;a href="https://jascoinc.com/learning-center/best-practices/calibrate-cd-scale-acs/" rel="noopener noreferrer"&gt;JASCO’s published J-Series CD-scale procedure&lt;/a&gt; uses a chemical reference solution.&lt;/p&gt;

&lt;h2&gt;
  
  
  Why the detector matters when the antibody signal is weak
&lt;/h2&gt;

&lt;p&gt;The Chirascan Q100 and V100 use a &lt;a href="https://www.photophysics.com/faqs/methods-techniques/cd-instrumentation-faqs/" rel="noopener noreferrer"&gt;large-area avalanche photodiode&lt;/a&gt;. The standard detector on the &lt;a href="https://jascoinc.com/products/spectroscopy/circular-dichroism/j-1000-series-models/j-1500-circular-dichroism-spectrophotometer/" rel="noopener noreferrer"&gt;JASCO J-1500&lt;/a&gt; is a photomultiplier tube. Applied Photophysics reports that its photodiode converts incoming UV light into an electrical signal more efficiently than a conventional photomultiplier. At the same light level and scan time, that can make a weak feature easier to distinguish from noise. That matters in near-UV CD, where a small change in how an antibody folds can produce a faint change in the curve.&lt;/p&gt;

&lt;p&gt;Applied Photophysics recorded an &lt;a href="https://www.photophysics.com/media/zmbjzcel/product-information-sheet_chirascan-q100.pdf#page=3" rel="noopener noreferrer"&gt;unsmoothed near-UV spectrum of lysozyme at &lt;strong&gt;0.05 mg/mL&lt;/strong&gt;&lt;/a&gt; on the Q100, using a 10 mm cell and ten minutes each for the baseline and sample. For antibody lots, the benefit of a cleaner signal is being able to tell whether a small shift between lots stands out above the variation among replicates.&lt;/p&gt;

&lt;h2&gt;
  
  
  Three controls help you decide which differences to trust
&lt;/h2&gt;

&lt;p&gt;In a &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/01/far-uv-cd-in-biotherapeutic-development-application-note.pdf" rel="noopener noreferrer"&gt;Novartis study on the Chirascan V100&lt;/a&gt;, two structurally similar antibodies showed a trough near 215 nm. Their clearest difference appeared at &lt;strong&gt;195 nm&lt;/strong&gt;. By mixing the antibodies in known proportions, the team calculated a &lt;strong&gt;14% detection limit&lt;/strong&gt; and a &lt;strong&gt;49% quantification limit&lt;/strong&gt; for the second antibody in that mixture. Your own antibody pair, formulation and method will determine how small a difference you can detect.&lt;/p&gt;

&lt;p&gt;I’d use three controls when comparing lots.&lt;/p&gt;

&lt;ul&gt;
&lt;li&gt;
&lt;strong&gt;A formulation blank.&lt;/strong&gt; Check the buffer background and sample absorbance to see which wavelengths you can trust.&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Independent preparations of one reference lot.&lt;/strong&gt; See how much two curves can differ simply because someone diluted and loaded the sample again.&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;A blinded sample with a known change.&lt;/strong&gt; Choose the smallest change that would trigger follow-up. Record whether you can distinguish the sample from the reference replicates before revealing its identity.&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;For labs doing this regularly, Applied Photophysics reports &lt;a href="https://www.photophysics.com/media/zmbjzcel/product-information-sheet_chirascan-q100.pdf#page=8" rel="noopener noreferrer"&gt;48 buffer–sample pairs in 24 hours for isothermal Q100 measurements&lt;/a&gt;. Plan a separate series for each flow cell and count your blanks and replicates when translating that figure into lots per day.&lt;/p&gt;

&lt;h2&gt;
  
  
  Analysis Workbench makes it easier to explain a flagged lot
&lt;/h2&gt;

&lt;p&gt;Say one antibody lot comes back with a lower estimate of beta-sheet content. Before deciding what to do with it, you need to know how much that result depends on the way the curve was fitted. &lt;strong&gt;Chirascan now puts the raw spectrum, the structural estimate and the evidence for that estimate in one place.&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;With &lt;a href="https://nicoyalife.com/blog/introducing-analysis-workbench-for-chirascan/" rel="noopener noreferrer"&gt;Analysis Workbench&lt;/a&gt;, you can subtract the formulation blank, average the replicates and fit the same far-UV spectrum with three published methods in one application. Overlay each fit on the measurement and you can see which features it reproduces. The residual plot shows exactly where the two curves disagree. If only one method suggests a loss of beta-sheet and its fit misses the band in question, you know where to focus before flagging the lot.&lt;/p&gt;

&lt;p&gt;Workbench saves each processing step and its results in the same document. A second analyst can reopen it, trace the estimate back to the measured curve and see why the team made the call. Nobody has to piece the analysis together from exported spectra, screenshots and a spreadsheet.&lt;/p&gt;

&lt;h2&gt;
  
  
  What to keep an eye on
&lt;/h2&gt;

&lt;p&gt;Nicoya &lt;a href="https://nicoyalife.com/blog/introducing-analysis-workbench-for-chirascan/" rel="noopener noreferrer"&gt;plans to add batch processing, integrated higher-order structure analysis and an API&lt;/a&gt; so Workbench can connect with other software. The announcement doesn’t give a release date yet, so keep an eye on this one.&lt;/p&gt;

&lt;p&gt;Imagine testing a protein against &lt;strong&gt;30 compounds at three concentrations&lt;/strong&gt;. That’s 90 conditions before you count the controls. Batch processing could apply the same analysis to each condition. Depending on what the API supports, your lab could send reviewed results to an electronic lab notebook or feed spectra, compound identities and replicate quality into an AI model to rank the next experiments. Your team could decide which steps to automate and where a scientist reviews the curve.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;I’d choose the Q100 for an antibody comparability program.&lt;/strong&gt; Its flow cells let you preserve far-UV detail in an absorbing buffer and strengthen weak near-UV signals. Workbench gives you the evidence behind a structural estimate when a lot looks different. I’d give the software roadmap real weight in that decision, too. If your lab grows from comparing two lots to screening dozens of compounds, planned batch analysis and an API could let you apply the method you already trust at that scale, with your team choosing which decisions still need a scientist.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>hardware</category>
      <category>science</category>
      <category>tools</category>
    </item>
    <item>
      <title>Already Have a QuantStudio? When Is a Dedicated Protein Stability Instrument Worth It?</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Mon, 23 Nov 2026 00:35:38 +0000</pubDate>
      <link>https://dev.to/dessygil/already-have-a-quantstudio-when-is-a-dedicated-protein-stability-instrument-worth-it-2ffn</link>
      <guid>https://dev.to/dessygil/already-have-a-quantstudio-when-is-a-dedicated-protein-stability-instrument-worth-it-2ffn</guid>
      <description>&lt;p&gt;Would you drop a promising buffer because it gives your protein a messy melt curve on the QuantStudio? I’d check the well containing buffer and dye but no protein. Even a clean blank leaves a question open. &lt;strong&gt;Could the dye itself be changing how the protein unfolds?&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;If your QuantStudio reliably ranks your samples and there’s time on the instrument, I’d keep using it. I’d look at SUPR-DSF when the dye starts deciding which formulations make the shortlist. For a lab already running protein melts on qPCR plates, the bench workflow barely changes.&lt;/p&gt;

&lt;h2&gt;
  
  
  A dye can shift the melt it’s meant to measure
&lt;/h2&gt;

&lt;p&gt;&lt;a href="https://cmi.hms.harvard.edu/sites/g/files/omnuum4016/files/2025-03/CMI%20QuantStudio%20DSF%20Getting%20Started%20Guide.pdf" rel="noopener noreferrer"&gt;Harvard Medical School’s guide for its modified QuantStudio 6/7&lt;/a&gt; describes dye-based differential scanning fluorimetry (DSF) on a real-time PCR (qPCR) instrument. SYPRO Orange gets brighter when it binds to water-repelling patches exposed as a protein unfolds. The midpoint of a clear transition gives you an apparent melting temperature (&lt;em&gt;Tm&lt;/em&gt;).&lt;/p&gt;

&lt;p&gt;If the dye binds more readily to the unfolded protein, it can favour that form as the sample heats. In &lt;a href="https://doi.org/10.1021/bi101414z" rel="noopener noreferrer"&gt;Layton and Hellinga’s study&lt;/a&gt;, increasing the SYPRO Orange concentration tenfold lowered the apparent &lt;em&gt;Tm&lt;/em&gt; of maltose-binding protein by about &lt;strong&gt;6 °C&lt;/strong&gt;. Over the same range, a second protein, staphylococcal nuclease A, showed almost no change.&lt;/p&gt;

&lt;p&gt;I’d make two checks before dropping a formulation.&lt;/p&gt;

&lt;ul&gt;
&lt;li&gt;
&lt;strong&gt;Run a protein-free blank for each formulation.&lt;/strong&gt; &lt;a href="https://doi.org/10.1371/journal.pone.0177024" rel="noopener noreferrer"&gt;Kroeger and colleagues&lt;/a&gt; measured a transition near 68 °C on a qTOWER 2.0 from SYPRO Orange and EDTA in protein-free buffer at pH 10. If the blank reproduces the peak, I’d set that &lt;em&gt;Tm&lt;/em&gt; aside.&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Try two dye concentrations.&lt;/strong&gt; Hold the protein, buffers, final solvent concentration and heating rate constant. If both curves shift but the same buffer wins, the assay may still serve its purpose. If the ranking flips, I’d run that pair without dye.&lt;/li&gt;
&lt;/ul&gt;

&lt;h2&gt;
  
  
  How much of the plate workflow changes?
&lt;/h2&gt;

&lt;p&gt;Both methods use inexpensive, standard qPCR plates and optical seals. Dispense the protein and buffers, include blanks and replicates, seal the plate and start the temperature ramp. Match the plate to the block. Harvard’s setup uses a 96-well fast plate, and &lt;a href="https://documents.thermofisher.com/TFS-Assets/LSG/manuals/MAN0018045_QS_6Pro_7Pro_UG.pdf" rel="noopener noreferrer"&gt;QuantStudio also comes in 384-well configurations&lt;/a&gt;.&lt;/p&gt;

&lt;p&gt;On &lt;a href="https://nicoyalife.com/supr-dsf/" rel="noopener noreferrer"&gt;SUPR-DSF&lt;/a&gt;, you can fill a standard 384-well qPCR plate by hand or with a liquid handler. &lt;strong&gt;You leave the dye out.&lt;/strong&gt; The reader records the protein’s own fluorescence spectrum as it heats. Changes around tryptophan and tyrosine can shift the wavelengths they emit. I’d check for a clear change relative to the formulation blank at the &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/01/Thermal-melt-analysis-of-proteins-lacking-tryptophan-residues.pdf" rel="noopener noreferrer"&gt;protein concentration I can afford to screen&lt;/a&gt;.&lt;/p&gt;

&lt;p&gt;At the U.S. pack prices I checked, a &lt;a href="https://www.labsource.com/style/framestar-384-well-skirted-pcr-plates-50-plates-case" rel="noopener noreferrer"&gt;black 384-well plate&lt;/a&gt; and an &lt;a href="https://www.thomassci.com/p/pcr-seal1" rel="noopener noreferrer"&gt;optical seal&lt;/a&gt; come to &lt;strong&gt;$13.85 together&lt;/strong&gt;. That’s &lt;strong&gt;3.6 cents of plastic per well&lt;/strong&gt; on a full plate, or about 11 cents for three replicate wells. For smaller runs, divide $13.85 by the wells you actually fill, and you'll be able to see it's more inexpensive compared to any other method no matter how you look at it.&lt;/p&gt;

&lt;h2&gt;
  
  
  What if the dye struggles with an ingredient you need?
&lt;/h2&gt;

&lt;p&gt;&lt;a href="https://doi.org/10.1021/acs.molpharmaceut.4c01496" rel="noopener noreferrer"&gt;Cohrs and colleagues tested this with lysozyme and polysorbate 80&lt;/a&gt;. In this peer-reviewed study, coauthored by Protein Stable scientists, the team used the same model of black 384-well PCR plate for dye-based measurements on a Bio-Rad CFX384 Touch and dye-free measurements on SUPR-DSF.&lt;/p&gt;

&lt;p&gt;At &lt;strong&gt;0.1 mg/mL polysorbate 80&lt;/strong&gt;, the SYPRO Orange background nearly hid the unfolding transition. SUPR-DSF resolved a curve across the full range tested, up to &lt;strong&gt;10 mg/mL&lt;/strong&gt;. That’s where I’d want the dye-free measurement. I could keep the surfactant at the concentration the formulation calls for and still follow the protein as it unfolds.&lt;/p&gt;

&lt;h2&gt;
  
  
  What 96 trastuzumab formulations showed in one run
&lt;/h2&gt;

&lt;p&gt;In &lt;a href="https://www.photophysics.com/media/ch4in3ad/formulation-screen-of-trastuzumab-using-the-supr-dsf.pdf" rel="noopener noreferrer"&gt;Protein Stable’s trastuzumab study&lt;/a&gt;, the manufacturer measured &lt;strong&gt;96 formulation conditions on one 384-well plate in approximately 1.5 hours&lt;/strong&gt;, using &lt;strong&gt;2 µg of antibody in 20 µL per well&lt;/strong&gt;. The shift in average emission wavelength showed when unfolding began (the onset) and the midpoints of two transitions.&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Formulation condition&lt;/th&gt;
&lt;th&gt;Unfolding onset (°C)&lt;/th&gt;
&lt;th&gt;First &lt;em&gt;Tm&lt;/em&gt; (°C)&lt;/th&gt;
&lt;th&gt;Second &lt;em&gt;Tm&lt;/em&gt; (°C)&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Control&lt;/td&gt;
&lt;td&gt;66.2&lt;/td&gt;
&lt;td&gt;73.2&lt;/td&gt;
&lt;td&gt;81.2&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Glycine&lt;/td&gt;
&lt;td&gt;67.0&lt;/td&gt;
&lt;td&gt;73.8&lt;/td&gt;
&lt;td&gt;83.7&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;L-proline&lt;/td&gt;
&lt;td&gt;66.9&lt;/td&gt;
&lt;td&gt;73.8&lt;/td&gt;
&lt;td&gt;81.8&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;D-sorbitol&lt;/td&gt;
&lt;td&gt;69.5&lt;/td&gt;
&lt;td&gt;76.3&lt;/td&gt;
&lt;td&gt;85.0&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;Glycine and proline tie if you keep only the first &lt;em&gt;Tm&lt;/em&gt;. Their second transitions were &lt;strong&gt;1.9 °C apart&lt;/strong&gt;. If I had room for one follow-up and wanted to delay early unfolding, I’d take D-sorbitol. Its onset was &lt;strong&gt;3.3 °C higher&lt;/strong&gt; than the control. I’d then compare &lt;a href="https://pubmed.ncbi.nlm.nih.gov/38556000/" rel="noopener noreferrer"&gt;aggregation during storage&lt;/a&gt; in the sorbitol formulation and the control.&lt;/p&gt;

&lt;p&gt;If recovery matters, SUPR-DSF can also &lt;a href="https://dev.to/dessygil/beyond-tm-what-supr-dsf-adds-to-a-protein-stability-screen-4lp"&gt;follow the protein as it cools&lt;/a&gt;. In a separate &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/04/MM-0102_MSF_v10.pdf#page=8" rel="noopener noreferrer"&gt;Nicoya study&lt;/a&gt;, lysozyme melted near 72 °C at both pH 3 and pH 7.4. An overnight heating-and-cooling experiment showed that its fluorescence largely recovered at pH 3. At pH 7.4 a lasting change appeared after heating to about 73 °C. I’d follow that difference with an activity test.&lt;/p&gt;

&lt;h2&gt;
  
  
  The two samples I’d bring before buying
&lt;/h2&gt;

&lt;p&gt;&lt;strong&gt;Bring one sample that gives a clean qPCR melt and one your team struggles to interpret.&lt;/strong&gt; For each, compare a reference buffer with a formulation you might actually advance. Split the same protein stock across the two instruments, match concentrations and heating rates, and run blanks and replicates.&lt;/p&gt;

&lt;p&gt;The clean sample tells you whether each method reproduces a ranking you trust. For the difficult sample, look for a transition distinct from the blank and a difference between buffers larger than the spread among replicates. If the methods favour different buffers, take both into the activity or storage test that matters to the project.&lt;/p&gt;

&lt;p&gt;If the dye-free run gives you a repeatable reason to advance a buffer the team was ready to drop, I’d put those two curves on the first page of the purchase request. &lt;strong&gt;For a lab making that choice week after week, I’d choose SUPR-DSF.&lt;/strong&gt; You keep the inexpensive plate workflow and the ingredient your formulation needs.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>hardware</category>
      <category>science</category>
    </item>
    <item>
      <title>Replacing a Biacore T200? Three SPR Assays I’d Run on Nicoya Alto First</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Sun, 22 Nov 2026 19:58:47 +0000</pubDate>
      <link>https://dev.to/dessygil/replacing-a-biacore-t200-three-spr-assays-id-run-on-nicoya-alto-first-3bam</link>
      <guid>https://dev.to/dessygil/replacing-a-biacore-t200-three-spr-assays-id-run-on-nicoya-alto-first-3bam</guid>
      <description>&lt;p&gt;A lab brings 20 µL of purified protein to your core and needs 10 µL back for Friday’s cell assay. Before signing for a new surface plasmon resonance (SPR) instrument, I’d ask the demo team to measure binding, repeat the measurement and show me what’s left in the tube.&lt;/p&gt;

&lt;p&gt;Whether you’re buying your first Biacore or replacing a T200, I’d give &lt;a href="https://nicoyalife.com/alto/" rel="noopener noreferrer"&gt;Nicoya Alto&lt;/a&gt; the other demo slot. Alto can prepare a dilution series on its disposable cartridge from &lt;strong&gt;as little as 2 µL in a sample well&lt;/strong&gt;. &lt;/p&gt;

&lt;h2&gt;
  
  
  1. Can a regular user repeat the routine assay?
&lt;/h2&gt;

&lt;p&gt;Pick a known binder, a nonbinder and two candidates your core has already ranked. Code the samples. After training, let an occasional user run the established method and record any help they need. &lt;a href="https://nicoyalife.com/blog/how-cros-can-acess-spr/" rel="noopener noreferrer"&gt;Radix BioSolutions told Nicoya&lt;/a&gt; that its team had Alto running within days and went on to train its own new hires.&lt;/p&gt;

&lt;p&gt;In &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/01/Characterization-of-Biomolecular-Interactions-using-Alto-Comparison-to-Conventional-SPR.pdf" rel="noopener noreferrer"&gt;Nicoya’s study of an antibody fragment binding green fluorescent protein&lt;/a&gt;, Alto made five concentrations from one stock. Nicoya reported affinities of &lt;strong&gt;8.6 nM on Alto and 10.0 nM on its comparator&lt;/strong&gt;, with &lt;strong&gt;28 and 96 minutes of operator time&lt;/strong&gt;, respectively. Dilution preparation accounted for 25 minutes of the difference in that experiment. Time that step on the Biacore you’re considering.&lt;/p&gt;

&lt;p&gt;It's also important to note that all fluidics are contained on the cartridge, so if you want to use crude, it's completely fine. There is no clogging no standard maintenance after every run, you simply just pop in another cartridge and you are on your way.&lt;/p&gt;

&lt;h2&gt;
  
  
  2. Does the difficult assay change which candidate you advance?
&lt;/h2&gt;

&lt;p&gt;In &lt;a href="https://nicoyalife.com/blog/comparison-study-spr-instruments/" rel="noopener noreferrer"&gt;Nicoya’s historical OpenSPR–T200 comparison&lt;/a&gt;, the same protein pair gave an equilibrium dissociation constant (KD) of &lt;strong&gt;1.53 nM on OpenSPR and 0.686 nM on the T200&lt;/strong&gt;. Lower values mean tighter binding. Both results clear a 10 nM cutoff. Only one clears 1 nM. The two runs used different amounts of protein on the sensor and different times to observe dissociation.&lt;/p&gt;

&lt;h2&gt;
  
  
  3. How much of the scarce sample comes back?
&lt;/h2&gt;

&lt;p&gt;At &lt;strong&gt;0.5 mg/mL&lt;/strong&gt;, reserving half of that 20 µL vial for cell work leaves &lt;strong&gt;5 µg for SPR&lt;/strong&gt;. Give each platform the same allowance from matched stock. Each 2 µL load uses 1 µg. Count every withdrawal for setup, controls and an independent repeat, including material left behind in wells.&lt;/p&gt;

&lt;p&gt;In &lt;a href="https://nicoyalife.com/blog/welcome-to-the-revolution/" rel="noopener noreferrer"&gt;Nicoya’s semaglutide experiment on Revo&lt;/a&gt;, the team used 2 µL of each sample to study binding to the GLP-1 receptor and human serum albumin. Revo made the dilution series on the cartridge. Use the stock concentration your labs can actually supply and report the total amount consumed per confirmed result.&lt;/p&gt;

&lt;h2&gt;
  
  
  What would last week’s bookings have cost?
&lt;/h2&gt;

&lt;p&gt;Alto takes the &lt;a href="https://store.nicoyalife.com/products/16-channel-carboxyl-cartridge-copy" rel="noopener noreferrer"&gt;same US$85 four-channel carboxyl cartridge&lt;/a&gt; as Revo. You can run Tuesday’s pilot on four channels and Friday’s antibody panel on 16. These are &lt;a href="https://store.nicoyalife.com/collections/digital-spr-sensor-cartridges" rel="noopener noreferrer"&gt;Nicoya’s U.S. list prices for single-use carboxyl cartridges&lt;/a&gt; as of November 2026.&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;System&lt;/th&gt;
&lt;th&gt;Compatible carboxyl cartridges&lt;/th&gt;
&lt;th&gt;When I’d price it&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Revo 4&lt;/td&gt;
&lt;td&gt;4 channels ($85)&lt;/td&gt;
&lt;td&gt;Routine projects fit in one booking. There’s an &lt;a href="https://nicoyalife.com/blog/welcome-to-the-revolution/" rel="noopener noreferrer"&gt;upgrade to eight channels&lt;/a&gt; if demand grows.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Revo 8&lt;/td&gt;
&lt;td&gt;4 ($85) or 8 ($110)&lt;/td&gt;
&lt;td&gt;References and repeats regularly push a panel into a second four-channel run.&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Alto&lt;/td&gt;
&lt;td&gt;4 ($85), 8 ($110) or 16 ($135)&lt;/td&gt;
&lt;td&gt;Small submissions alternate with full panels, or the core wants robotic cartridge loading.&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;If one 16-channel cartridge holds the same panel, controls and repeats as two eight-channel Nicoya cartridges, the cartridge cost is &lt;strong&gt;$135 versus $220&lt;/strong&gt;. For the Biacore quote, spread the chip cost across the accepted results you get while the &lt;a href="https://info.cytivalifesciences.com/Biacore-help-files_General-recommendations-for-regeneration.html" rel="noopener noreferrer"&gt;sensor surface retains its activity&lt;/a&gt;. Add reagents, tips and reruns on both sides. Five concentrations used to estimate one affinity count as one result.&lt;/p&gt;

&lt;p&gt;For overnight work, ask when a person last touches the sample. &lt;a href="https://cdn.cytivalifesciences.com/api/public/content/digi-32607-original" rel="noopener noreferrer"&gt;Cytiva lists up to 72 hours of unattended operation for the Biacore 8S+&lt;/a&gt;. Both Revo and Alto make dilutions without an external robot, and &lt;a href="https://nicoyalife.com/revo/" rel="noopener noreferrer"&gt;Revo supports software integration&lt;/a&gt;. The optional &lt;a href="https://nicoyalife.com/alto-automation-suite/" rel="noopener noreferrer"&gt;Alto Automation Suite&lt;/a&gt; also supports robotic cartridge preparation and loading. In the &lt;a href="https://nicoyalife.com/blog/balance-project-advances-autonomous-bioprocessing-with-alto-digital-spr/" rel="noopener noreferrer"&gt;BALANCE project&lt;/a&gt;, Labman’s robot collected and prepared bioreactor samples, and Alto measured antibody concentration directly in crude culture supernatant. Include the hardware, software and integration each workflow needs in its quote.&lt;/p&gt;

&lt;h2&gt;
  
  
  The scorecard I’d take to the equipment committee
&lt;/h2&gt;

&lt;p&gt;Use one copy for each assay. A recent T200 run can serve as your baseline.&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;What to record&lt;/th&gt;
&lt;th&gt;Quoted Biacore model&lt;/th&gt;
&lt;th&gt;Alto&lt;/th&gt;
&lt;th&gt;Revo 4 or 8&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Usable candidate results / candidates attempted&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Target and sample consumed, including controls and repeats (µg each)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Chip or cartridge, reagents and tips per usable result (US$)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Hands-on staff minutes / changeover minutes&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Method changes and extra development runs&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;I’d price Revo first for a core whose panels fit into four or eight channels. For a shared core with scarce samples and a growing antibody queue, I’d replay last week’s bookings on Alto and the proposed Biacore using the costs and staff time measured in the demos. Count how many groups would get a result by Friday within the core’s budget.&lt;/p&gt;

&lt;p&gt;If Alto confirms which binder to advance, returns the 10 µL for the cell assay and finishes another lab’s panel that would otherwise wait until Monday, &lt;strong&gt;I’d put Alto on the purchase order.&lt;/strong&gt;&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
    </item>
    <item>
      <title>Olezarsen Targets RNA. How Do You Show an Antisense Candidate Forms the Duplex You Expect?</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Sun, 22 Nov 2026 18:26:47 +0000</pubDate>
      <link>https://dev.to/dessygil/olezarsen-targets-rna-how-do-you-show-an-antisense-candidate-forms-the-duplex-you-expect-1dcg</link>
      <guid>https://dev.to/dessygil/olezarsen-targets-rna-how-do-you-show-an-antisense-candidate-forms-the-duplex-you-expect-1dcg</guid>
      <description>&lt;p&gt;If two antisense candidates bind the same stretch of RNA and both pairs melt near 70 °C, would you advance them both? In &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC10685824/" rel="noopener noreferrer"&gt;a study by Rouven Stulz and colleagues&lt;/a&gt;, one candidate let go of the RNA faster in every run at 37 °C. You’d miss that difference if the melting temperature were the only number in your spreadsheet.&lt;/p&gt;

&lt;p&gt;On November 17, 2026, &lt;a href="https://ir.ionispharma.com/news-releases/news-release-details/tryngolzatm-olezarsen-approved-eu-severe-hypertriglyceridemia" rel="noopener noreferrer"&gt;Ionis announced an expanded EU indication for olezarsen&lt;/a&gt;, marketed as Tryngolza. The EU now authorizes its use alongside diet and other lipid-lowering therapies for adults with severe hypertriglyceridemia whose fasting triglycerides reach at least 880 mg/dL (10 mmol/L). Olezarsen works by &lt;a href="https://www.ema.europa.eu/en/documents/assessment-report/tryngolza-epar-public-assessment-report_en.pdf" rel="noopener noreferrer"&gt;pairing with &lt;em&gt;APOC3&lt;/em&gt; messenger RNA in liver cells&lt;/a&gt;. That gives an enzyme called RNase H1 a site to cut the RNA, reducing production of the apoC-III protein.&lt;/p&gt;

&lt;p&gt;In &lt;a href="https://dev.to/dessygil/your-rna-cd-spectrum-changed-what-does-that-mean-for-your-formulation-363l"&gt;my earlier post on RNA formulation&lt;/a&gt;, I looked at what happens when you change the buffer. Here I want to keep the RNA target fixed and change the chemistry of the antisense oligonucleotide (ASO). How would I tell whether that change helped?&lt;/p&gt;

&lt;h2&gt;
  
  
  Start with the strands before you mix them
&lt;/h2&gt;

&lt;p&gt;Stulz and colleagues worked with a different target from olezarsen, a 24-nucleotide stretch of &lt;em&gt;PCSK9&lt;/em&gt; RNA. Using an Applied Photophysics &lt;a href="https://nicoyalife.com/chirascan/" rel="noopener noreferrer"&gt;Chirascan V100&lt;/a&gt;, they collected circular dichroism (CD) spectra for the RNA alone, each candidate alone, and the mixtures. CD measures how differently a sample absorbs left- and right-circularly polarized light. In nucleic acids, it’s sensitive to how the bases stack.&lt;/p&gt;

&lt;p&gt;The individual strands turned out to matter. Two candidates already had a peak near 280 nm before they saw any RNA. A third had a peak near 270 nm. Adding the target &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC10685824/" rel="noopener noreferrer"&gt;changed the spectra of all three&lt;/a&gt;, while a nonbinding control showed no comparable change.&lt;/p&gt;

&lt;p&gt;That’s why I’d build the individual strands into the first run. Without them, it’s easy to credit pairing for a feature the candidate already had. CD gives an overall picture of how the strands are arranged. Pinpointing individual base pairs takes higher-resolution evidence.&lt;/p&gt;

&lt;p&gt;A &lt;a href="https://doi.org/10.1093/nar/gkag343" rel="noopener noreferrer"&gt;2026 study of fluorinated antisense candidates targeting &lt;em&gt;C9ORF72&lt;/em&gt; repeat RNA&lt;/a&gt; makes the case for measuring the &lt;strong&gt;whole spectrum&lt;/strong&gt;. Barber and colleagues used a &lt;strong&gt;Chirascan VX&lt;/strong&gt;. Two candidate duplexes looked much alike at 265 nm. Near 210 nm, their signals differed, and the authors concluded that one duplex more closely resembled the A-form helix typical of double-stranded RNA. If I’d chosen 265 nm as my only readout, I’d have called those samples much more similar than they were.&lt;/p&gt;

&lt;h2&gt;
  
  
  Follow the duplex through the melt
&lt;/h2&gt;

&lt;p&gt;Back in the &lt;em&gt;PCSK9&lt;/em&gt; study, Stulz and colleagues used a &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC10685824/" rel="noopener noreferrer"&gt;temperature-controlled Chirascan V100 to record a full spectrum at every degree from 40 to 90 °C&lt;/a&gt;. That’s why I’d want this setup for an antisense screen. I can see which peaks distinguish the paired sample at the start, then follow those same peaks in the same cuvette as the strands separate. The melting temperature (&lt;em&gt;Tₘ&lt;/em&gt;) gives me the midpoint. The spectra show me what changed on the way there.&lt;/p&gt;

&lt;p&gt;That 210 nm example is also where I’d use the V100’s option to &lt;a href="https://www.photophysics.com/media/obdjpb4c/chirascan-v100-user-manual.pdf" rel="noopener noreferrer"&gt;record absorbance alongside CD&lt;/a&gt;. If the distinction I care about is at the short-wavelength end, I want to know whether enough light reached the detector there. The absorbance trace helps me decide whether a shorter-path cuvette would give me a cleaner comparison.&lt;/p&gt;

&lt;p&gt;In &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC10685824/figure/fig2/" rel="noopener noreferrer"&gt;Figure 2B&lt;/a&gt;, two candidates had CD melting midpoints near 70 °C. ASO 1 had a central stretch of DNA flanked by modified nucleotides, a design called a &lt;em&gt;gapmer&lt;/em&gt;. ASO 3 had a 2′-O-methyl modification throughout. To tell how long each stayed paired at 37 °C, the team had to hold the temperature steady and measure release.&lt;/p&gt;

&lt;h2&gt;
  
  
  What was still bound after 17 minutes?
&lt;/h2&gt;

&lt;p&gt;For the &lt;em&gt;PCSK9&lt;/em&gt; experiment, the team used &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC10685824/" rel="noopener noreferrer"&gt;surface plasmon resonance (SPR)&lt;/a&gt;. They attached the RNA to a sensor, introduced each candidate, then switched to buffer and watched the signal fall as bound strands came off.&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Candidate&lt;/th&gt;
&lt;th&gt;CD melting midpoint&lt;/th&gt;
&lt;th&gt;Estimated fraction still bound after 17 min at 37 °C&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;ASO 1, gapmer&lt;/td&gt;
&lt;td&gt;About 70 °C&lt;/td&gt;
&lt;td&gt;72–85%&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;ASO 3, fully 2′-O-methyl&lt;/td&gt;
&lt;td&gt;About 70 °C&lt;/td&gt;
&lt;td&gt;44–70%&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;I calculated those ranges from the three fitted dissociation rates for each candidate in &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/instance/10685824/bin/CB-004-D3CB00072A-s001.pdf" rel="noopener noreferrer"&gt;supplementary Table S7&lt;/a&gt;, using the authors’ one-to-one binding model over their 17-minute observation window. The gapmer stayed paired longer in all three runs. That’s a useful distinction if time on target is what you’re trying to change.&lt;/p&gt;

&lt;h2&gt;
  
  
  What would I run on Alto next?
&lt;/h2&gt;

&lt;p&gt;Once I know two designs behave differently, I’d want to compare each one against both the intended target and a target with one mismatched base. That gives me a more useful question than “Which binds tightest?” &lt;strong&gt;Does the chemistry help the candidate stay on its intended target while allowing it to release the mismatch?&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;Nicoya’s &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/01/Characterization-of-Oligos-with-Alto_v7.pdf" rel="noopener noreferrer"&gt;complementary DNA study on Alto Digital SPR&lt;/a&gt; puts numbers on the sample and bench time for an oligonucleotide assay. Alto prepared five concentrations from a single stock directly on the cartridge, using &lt;strong&gt;2 µL of sample per interaction&lt;/strong&gt;. Nicoya reported &lt;strong&gt;48 repeat measurements of the same DNA pair in under five hours&lt;/strong&gt;, with about &lt;strong&gt;30 minutes of hands-on time&lt;/strong&gt; for setup and analysis.&lt;/p&gt;

&lt;p&gt;Here’s how I’d budget a comparison on &lt;a href="https://nicoyalife.com/alto/" rel="noopener noreferrer"&gt;Alto&lt;/a&gt;. Two candidates, two targets and duplicate runs make eight interactions. At the DNA study’s consumption, that’s &lt;strong&gt;8 µL of each candidate&lt;/strong&gt; for the measurements, plus material for setup and handling. That makes the mismatch control easier to keep when sample is scarce. I’d first verify that the modified ASO and RNA give a measurable binding and release signal on the chosen surface.&lt;/p&gt;

&lt;h2&gt;
  
  
  Which candidate deserves the cell experiment?
&lt;/h2&gt;

&lt;p&gt;A &lt;a href="https://doi.org/10.1038/s41598-021-90629-1" rel="noopener noreferrer"&gt;study of fluorescently labeled gapmers targeting &lt;em&gt;MALAT1&lt;/em&gt;&lt;/a&gt; shows why I’d carry the structural comparison into the cell work. Nilsson and colleagues used a temperature-controlled &lt;strong&gt;Chirascan&lt;/strong&gt; for CD spectra and melting measurements. Duplexes with a single label had spectra close to the unlabeled control. Two candidates with a pair of modified adenines showed small differences between &lt;strong&gt;280 and 340 nm&lt;/strong&gt;. Those same candidates reduced the target RNA less effectively in a separate cellular assay. If I were choosing a fluorescent label for my next experiment, I’d want one that preserved both the duplex spectrum and the activity of the original gapmer.&lt;/p&gt;

&lt;p&gt;For a drug that works like olezarsen, I’d also ask whether the chemistry supports cleavage. A gapmer’s central DNA stretch pairs with RNA to form the &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC10685824/" rel="noopener noreferrer"&gt;substrate recognized by RNase H1&lt;/a&gt;. A fully 2′-O-methyl candidate can pair with RNA while lacking that central DNA stretch. For olezarsen itself, researchers measured the intended effect directly. In &lt;a href="https://www.accessdata.fda.gov/drugsatfda_docs/nda/2025/218614Orig1s000IntegratedR.pdf" rel="noopener noreferrer"&gt;a study reviewed by the FDA&lt;/a&gt;, olezarsen reduced &lt;em&gt;APOC3&lt;/em&gt; RNA by up to &lt;strong&gt;82% in primary human liver cells&lt;/strong&gt;.&lt;/p&gt;

&lt;p&gt;If two candidates melt near 70 °C, I’d spend the next sample on the question that could change my decision. If I’m unsure what formed, I’d compare the full Chirascan spectra with the individual strands. If I’m choosing between designs for their ability to distinguish a single mismatch, I’d use Alto to compare how they release the matched and mismatched targets. And if I’m choosing which gapmer to advance, I want to see the target RNA come down in cells. That gives me a reason to order more of one molecule, even when its melting temperature looks just like the other one’s.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>biotech</category>
      <category>science</category>
    </item>
    <item>
      <title>An Alzheimer’s Antibody Binds Its Receptor. How Do You Know It Reaches the Brain?</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Sat, 21 Nov 2026 23:23:35 +0000</pubDate>
      <link>https://dev.to/dessygil/an-alzheimers-antibody-binds-its-receptor-how-do-you-know-it-reaches-the-brain-5c4n</link>
      <guid>https://dev.to/dessygil/an-alzheimers-antibody-binds-its-receptor-how-do-you-know-it-reaches-the-brain-5c4n</guid>
      <description>&lt;p&gt;Two experimental antibody shuttles reached the same average concentration in mouse brain one day after injection. By day seven, one measured &lt;strong&gt;1.8 nM&lt;/strong&gt; and the other &lt;strong&gt;2.7 nM&lt;/strong&gt;. A team choosing between them on day one would have missed a difference that mattered six days later.&lt;/p&gt;

&lt;p&gt;That finding from a &lt;a href="https://www.nature.com/articles/s41551-026-01718-3#Fig8" rel="noopener noreferrer"&gt;University of Michigan brain-shuttle study&lt;/a&gt; came to mind when I read &lt;a href="https://www.roche.com/media/releases/med-cor-2026-11-10" rel="noopener noreferrer"&gt;Roche’s November 16 programme at the Clinical Trials on Alzheimer’s Disease meeting&lt;/a&gt;. Roche featured two kinds of PET imaging for its investigational Alzheimer’s antibody, &lt;strong&gt;trontinemab&lt;/strong&gt;. In one, investigators followed a radioactive label attached to the antibody. In the other, a separate tracer showed how amyloid plaque burden changed.&lt;/p&gt;

&lt;p&gt;For a team developing an Alzheimer’s antibody, those measurements answer different questions. Does the molecule recognize the intended form of amyloid? Does its shuttle bind the receptor in the species being tested? And how much antibody reaches brain tissue long enough to act?&lt;/p&gt;

&lt;h2&gt;
  
  
  Would your animal model recognize the shuttle?
&lt;/h2&gt;

&lt;p&gt;&lt;a href="https://medically.roche.com/content/dam/pdmahub/restricted/neurology/ctad-2025/CTAD-2025-presentation-kulic-brainshuttle-tm-ad-new-interim-results.pdf" rel="noopener noreferrer"&gt;Trontinemab uses transferrin receptor 1&lt;/a&gt; as its route across the blood–brain barrier. The Michigan group studied a different shuttle target, &lt;strong&gt;CD98hc&lt;/strong&gt;, and encountered a problem worth catching early. Their starting antibody recognized human and cynomolgus monkey CD98hc. Binding to the mouse version was undetectable.&lt;/p&gt;

&lt;p&gt;In their &lt;a href="https://www.nature.com/articles/s41551-026-01718-3" rel="noopener noreferrer"&gt;peer-reviewed study in &lt;em&gt;Nature Biomedical Engineering&lt;/em&gt;&lt;/a&gt;, Wen-Hao Wu, Neelan Sivaneri and colleagues used &lt;strong&gt;Nicoya Alto&lt;/strong&gt; to compare four antibodies against CD98hc from all three species. Surface plasmon resonance (SPR) let them follow each interaction as it formed and dissociated. They identified variants that recognized all three versions of the receptor and then evaluated brain exposure in separate animal experiments.&lt;/p&gt;

&lt;p&gt;That’s a comparison I’d want before interpreting a disappointing mouse study. If you’ve only tested the human receptor, low brain uptake leaves two explanations open. The shuttle may have bound the mouse receptor and travelled poorly, or it may barely have recognized the receptor in the first place.&lt;/p&gt;

&lt;h2&gt;
  
  
  What I’d put on the binding panel before imaging
&lt;/h2&gt;

&lt;p&gt;For a plaque-directed programme, I’d compare the parent antibody and each shuttle-equipped candidate against the &lt;strong&gt;same preparation of fibrillar amyloid&lt;/strong&gt;. I’d also run each candidate against human TfR1 and TfR1 from the study species. With a parent and three new designs, that’s already &lt;strong&gt;12 antibody–target pairs&lt;/strong&gt; before references and repeats.&lt;/p&gt;

&lt;p&gt;The amyloid preparation deserves as much attention as the antibody. In a &lt;a href="https://www.nature.com/articles/s41467-025-57341-4#Fig3" rel="noopener noreferrer"&gt;&lt;em&gt;Nature Communications&lt;/em&gt; study of p3, a shorter amyloid peptide&lt;/a&gt;, Tian and colleagues used an &lt;strong&gt;Applied Photophysics Chirascan&lt;/strong&gt; to follow the change from a largely disordered peptide to β-sheet-rich fibrils. Electron microscopy showed the assemblies that had formed. I’d record the aggregation state and split one preparation across the antibody panel. Otherwise, a difference between curves could come from what was in the amyloid tube.&lt;/p&gt;

&lt;p&gt;For the binding assay itself, I’d borrow a control from &lt;a href="https://www.nature.com/articles/s41467-025-65148-6" rel="noopener noreferrer"&gt;Carstens and colleagues’ antibody study&lt;/a&gt;. They used &lt;strong&gt;Alto&lt;/strong&gt; to test binding to human claudin-18.2 across five concentrations, with a blank and an unrelated antibody as controls. That was an oncology study, but the control earns its place in an amyloid assay too. If the amyloid preparation also sticks to an unrelated antibody, I’d investigate that signal before using the curve to rank a candidate.&lt;/p&gt;

&lt;p&gt;This is where the &lt;a href="https://nicoyalife.com/alto/" rel="noopener noreferrer"&gt;16-channel Alto&lt;/a&gt; makes a practical difference. It prepares serial dilutions on the cartridge, and Nicoya specifies a minimum sample volume of &lt;strong&gt;2 µL&lt;/strong&gt;. For a lab running smaller panels, the &lt;a href="https://nicoyalife.com/revo/" rel="noopener noreferrer"&gt;four- or eight-channel Revo&lt;/a&gt; offers automated serial dilutions with the same minimum volume. When the first purification yields less antibody than expected, I’d use that flexibility to keep the species comparison and repeat the borderline result. Those are the measurements I’d most regret cutting later.&lt;/p&gt;

&lt;h2&gt;
  
  
  What day seven revealed
&lt;/h2&gt;

&lt;p&gt;In the Michigan study, the researchers used radiolabelled antibodies to measure brain concentrations after a single dose in wild-type mice. Two shuttles in &lt;a href="https://www.nature.com/articles/s41551-026-01718-3#Fig8" rel="noopener noreferrer"&gt;Figure 8&lt;/a&gt; illustrate why sampling time belongs in any discussion of brain delivery.&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;CD98hc shuttle&lt;/th&gt;
&lt;th&gt;Day 1 brain concentration&lt;/th&gt;
&lt;th&gt;Day 7 brain concentration&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;IgG/D4-4&lt;/td&gt;
&lt;td&gt;3.1 ± 0.2 nM&lt;/td&gt;
&lt;td&gt;1.8 ± 0.1 nM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;IgG/3.5D19&lt;/td&gt;
&lt;td&gt;3.1 ± 0.2 nM&lt;/td&gt;
&lt;td&gt;2.7 ± 0.1 nM&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;&lt;em&gt;Mean ± standard deviation, with three to four mice per time point.&lt;/em&gt;&lt;/p&gt;

&lt;p&gt;The binding experiment established that both candidates could engage the mouse receptor. The tissue measurements showed how their exposure changed over time. To answer the next question for a plaque-directed antibody, I’d also want to see where it localized relative to blood vessels and plaques. A concentration averaged across a piece of brain leaves that detail unresolved.&lt;/p&gt;

&lt;h2&gt;
  
  
  What changed in the plaques?
&lt;/h2&gt;

&lt;p&gt;In its &lt;a href="https://medically.roche.com/global/en/neuroscience/ctad-2026/medical-material/CTAD-2026-presentation-kulic-trontinemab-in-alzheimers-disease-pdf.html" rel="noopener noreferrer"&gt;phase Ib/IIa CTAD presentation&lt;/a&gt;, Roche reported a decline of about &lt;strong&gt;70 Centiloids&lt;/strong&gt; on amyloid PET after six trontinemab doses of 1.2 mg/kg given four weeks apart. Centiloids express plaque burden on a standardized scale. For patients, the next question is whether treatment helps preserve memory and daily function. That is what the &lt;a href="https://clinicaltrials.gov/study/NCT07169578" rel="noopener noreferrer"&gt;phase III TRONTIER programme&lt;/a&gt; is designed to assess.&lt;/p&gt;

&lt;p&gt;If I were reviewing an underperforming candidate, I’d want the next experiment to change a specific decision. If amyloid recognition weakens when the shuttle is added, revisit the antibody format. If the shuttle misses the study species’ receptor, revisit the model. If both binding results hold up, measure tissue exposure over time before spending another design cycle chasing tighter affinity.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>biotech</category>
      <category>science</category>
    </item>
    <item>
      <title>Your AI-Designed Antibody Binds EGFR. Does It Bind at the Wrong pH?</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Sat, 21 Nov 2026 22:59:27 +0000</pubDate>
      <link>https://dev.to/dessygil/your-ai-designed-antibody-binds-egfr-does-it-bind-at-the-wrong-ph-2hm6</link>
      <guid>https://dev.to/dessygil/your-ai-designed-antibody-binds-egfr-does-it-bind-at-the-wrong-ph-2hm6</guid>
      <description>&lt;p&gt;Imagine your model gives you two antibodies. Both bind the human epidermal growth factor receptor (EGFR) about equally well at pH 6.5. You repeat the experiment at pH 7.4. One still binds strongly. The other gives you a curve you can barely distinguish from background.&lt;/p&gt;

&lt;p&gt;For this particular design brief, I’d take a closer look at the antibody with the flat curve.&lt;/p&gt;

&lt;p&gt;The &lt;a href="https://en.porevaopen.megalaxylab.com/challenges/egfr" rel="noopener noreferrer"&gt;Poreva Open EGFR challenge&lt;/a&gt;, which listed November 18, 2026, as its submission deadline, asked for molecules that bind human EGFR at pH 6.5 and show no detectable binding at pH 7.4. Human EGFR affinity accounts for &lt;strong&gt;20% of the score&lt;/strong&gt;. Once a design clears the affinity threshold, &lt;strong&gt;pH selectivity is worth 30%&lt;/strong&gt;. The organizers expect results in April 2027, but the scoring already tells us something about what makes a good candidate.&lt;/p&gt;

&lt;p&gt;Why would weaker binding earn a better score? &lt;a href="https://pubmed.ncbi.nlm.nih.gov/36458200/" rel="noopener noreferrer"&gt;Healthy tissues express EGFR too&lt;/a&gt;, and the space around cells in a solid tumor can be more acidic. An antibody that recognizes EGFR more readily under acidic conditions could favor tumor tissue. The first question a lab can answer is much simpler. Does changing the pH actually change binding enough to influence which antibody moves forward?&lt;/p&gt;

&lt;h2&gt;
  
  
  One extra column changes the shortlist
&lt;/h2&gt;

&lt;p&gt;A &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC9703009/#tbl1" rel="noopener noreferrer"&gt;study by Liu and colleagues&lt;/a&gt; gives us a real pair of antibodies to compare. Four years before the challenge, the team used surface plasmon resonance (SPR) to measure an engineered antibody called G532 and a closely related control. They reported the equilibrium dissociation constant, or &lt;em&gt;K&lt;/em&gt;D. A lower value means tighter binding.&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Antibody&lt;/th&gt;
&lt;th&gt;Human EGFR at pH 6.5&lt;/th&gt;
&lt;th&gt;Human EGFR at pH 7.4&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;G532&lt;/td&gt;
&lt;td&gt;294 nM&lt;/td&gt;
&lt;td&gt;3,900 nM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;G532 control&lt;/td&gt;
&lt;td&gt;406 nM&lt;/td&gt;
&lt;td&gt;243 nM&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;Cover the last column and I’d put those antibodies on the same shortlist. Uncover it and I’d make two different decisions. The control actually bound EGFR more tightly at pH 7.4. G532 bound about &lt;strong&gt;13 times more weakly&lt;/strong&gt; there. For a team trying to build in a preference for acidic conditions, G532 is the one I’d investigate.&lt;/p&gt;

&lt;p&gt;There’s a detail I’d keep attached to that result wherever the data go next. &lt;strong&gt;G532 still bound at pH 7.4.&lt;/strong&gt; A 13-fold shift is a useful lead. Calling it “no detectable binding” would give the next design round the wrong answer.&lt;/p&gt;

&lt;h2&gt;
  
  
  What I’d measure on Revo and Alto
&lt;/h2&gt;

&lt;p&gt;For a small batch of newly expressed antibodies, I’d start with the same concentration series at pH 6.5 and 7.4. I’d match each sample to its running buffer and include a reference surface and a buffer blank at each pH. A &lt;a href="https://nicoyalife.com/wp-content/uploads/2024/07/EBook_-_Mastering_kinetic_binding_assays.pdf#page=19" rel="noopener noreferrer"&gt;buffer mismatch can shift the SPR signal&lt;/a&gt;, which matters when a result near background could decide which antibody advances.&lt;/p&gt;

&lt;p&gt;This is where I see a good fit for &lt;a href="https://nicoyalife.com/revo/" rel="noopener noreferrer"&gt;Nicoya’s Revo&lt;/a&gt;. It comes in four- and eight-channel configurations, prepares serial dilutions on the cartridge and can work with as little as &lt;strong&gt;2 µL of sample&lt;/strong&gt;. When the first expression batch is small, I’d rather use that material to repeat the neutral-pH measurement than use it up preparing dilution series by hand. If the repeat stays flat, I’d record “no binding detected” &lt;strong&gt;and the highest concentration tested&lt;/strong&gt;. That gives the result meaning when someone opens the dataset six months later.&lt;/p&gt;

&lt;p&gt;For a promising lead, I’d use &lt;a href="https://nicoyalife.com/alto/" rel="noopener noreferrer"&gt;Alto’s 16-channel format&lt;/a&gt; to ask where the change happens. Nicoya’s &lt;a href="https://nicoyalife.com/wp-content/uploads/2024/07/EBook_-_Mastering_kinetic_binding_assays.pdf#page=19" rel="noopener noreferrer"&gt;kinetic assay guide&lt;/a&gt; documents up to &lt;strong&gt;eight different running buffers on one cartridge&lt;/strong&gt;. I’d use that flexibility to add intermediate pH values. An antibody that loses most of its binding by pH 6.8 would send me into the next cell experiment with a different expectation from one that still binds well at pH 7.2. You can’t see that difference from the two endpoints alone.&lt;/p&gt;

&lt;p&gt;I’d also look at how the antibody lets go. In a separate &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/01/MM-0076-Kinetic-analysis-of-an-antibody-in-serum-on-Alto.pdf" rel="noopener noreferrer"&gt;Nicoya application study on Alto&lt;/a&gt;, the team measured an antibody binding its target in buffer and in undiluted serum on the same cartridge. Its affinity shifted from &lt;strong&gt;9.31 nM to 15.4 nM&lt;/strong&gt;, while the measured dissociation rate &lt;strong&gt;more than doubled&lt;/strong&gt; in serum. The team changed the sample environment in that study. For an EGFR lead, I’d ask the equivalent question about pH. Does the antibody have more trouble attaching at pH 7.4, or does it attach and then release faster? The binding curves can help tell those possibilities apart.&lt;/p&gt;

&lt;h2&gt;
  
  
  What I’d send back to the model
&lt;/h2&gt;

&lt;p&gt;In &lt;a href="https://dev.to/dessygil/what-should-your-ai-model-learn-from-the-next-plate-of-experiments-361g"&gt;What Should Your AI Model Learn From the Next Plate of Experiments?&lt;/a&gt;, I wrote about choosing measurements that improve the next round of designs. For EGFR, I’d give the model a result for each pH, keep the concentration range with each result, and distinguish “below detection” from “never tested.” A single “EGFR binder” label would erase the most useful difference in that table.&lt;/p&gt;

&lt;p&gt;If a candidate binds well enough at pH 6.5 and repeatedly stays below detection at pH 7.4, that’s the one I’d spend the next cell experiment on. Then I’d ask whether the preference holds when EGFR sits on a cell surface. That’s a decision the team can act on today, while the much larger question of tumor selectivity in patients remains ahead.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>ai</category>
      <category>biotech</category>
      <category>machinelearning</category>
    </item>
    <item>
      <title>When Does Semaglutide Form Fibrils? What Circular Dichroism Can Tell You</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Sat, 21 Nov 2026 22:49:00 +0000</pubDate>
      <link>https://dev.to/dessygil/when-does-semaglutide-form-fibrils-what-circular-dichroism-can-tell-you-301l</link>
      <guid>https://dev.to/dessygil/when-does-semaglutide-form-fibrils-what-circular-dichroism-can-tell-you-301l</guid>
      <description>&lt;p&gt;In one solution, semaglutide formed long, twisted fibers. In another, the same peptide formed small, round clusters called micelles. What caught my attention in &lt;a href="https://doi.org/10.1021/acs.biomac.5c02669" rel="noopener noreferrer"&gt;Valeria Castelletto and colleagues’ semaglutide study&lt;/a&gt; was that you could see a change in the acidic sample before you ever looked at a microscope image. If I saw that change in a formulation screen, which sample would I send for imaging, and when?&lt;/p&gt;

&lt;p&gt;Semaglutide was back in the news on November 14, when &lt;a href="https://www.novonordisk.com/news-and-media/news-and-ir-materials/news-details.html?id=920561" rel="noopener noreferrer"&gt;Novo Nordisk announced its REDEFINE 9 results&lt;/a&gt; for CagriSema, its investigational combination of cagrilintide and semaglutide. The fibril finding comes from a separate March 31 paper. That team studied research-grade semaglutide in water. Its conclusions apply to those preparations, and the stability of the trial formulation and marketed products was outside the scope of the work.&lt;/p&gt;

&lt;h2&gt;
  
  
  What changed in the Chirascan spectrum?
&lt;/h2&gt;

&lt;p&gt;I’d start with &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC13080979/#fig2" rel="noopener noreferrer"&gt;Figure 2b&lt;/a&gt;. The researchers used an &lt;a href="https://nicoyalife.com/chirascan/" rel="noopener noreferrer"&gt;Applied Photophysics Chirascan&lt;/a&gt; to measure far-ultraviolet circular dichroism (CD). The shape of a CD spectrum tells you about the way the peptide backbone folds, averaged across the molecules in the sample.&lt;/p&gt;

&lt;p&gt;Look at the fresh semaglutide trifluoroacetate solution at &lt;strong&gt;1% by weight and pH 2.4&lt;/strong&gt;. Its spectrum had two dips, one at &lt;strong&gt;208 nm&lt;/strong&gt; and another at &lt;strong&gt;222 nm&lt;/strong&gt;, characteristic of an alpha helix. After &lt;strong&gt;40 days at 4 °C&lt;/strong&gt;, the curve had one broad dip near &lt;strong&gt;216 nm&lt;/strong&gt;, consistent with a shift toward beta-sheet structure. That answers one part of the timing question. The peptide had changed &lt;strong&gt;by&lt;/strong&gt; day 40. To find out how early that change was detectable, I’d want the samples from the weeks in between.&lt;/p&gt;

&lt;p&gt;One detail I’d borrow from &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC13080979/" rel="noopener noreferrer"&gt;their experimental setup&lt;/a&gt; is the choice of quartz cells with light paths of &lt;strong&gt;0.01 or 0.1 mm&lt;/strong&gt;. A &lt;a href="https://www.photophysics.com/knowledge-hub/how-low-can-we-go/" rel="noopener noreferrer"&gt;shorter light path&lt;/a&gt; lets more far-UV light through a concentrated solution. That matters here because semaglutide’s assembly depends on concentration. Diluting a sample to get a cleaner spectrum could change the very thing you’re trying to measure.&lt;/p&gt;

&lt;h2&gt;
  
  
  What made them call it a fibril?
&lt;/h2&gt;

&lt;p&gt;Take a look at &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC13080979/#fig1" rel="noopener noreferrer"&gt;Figure 1c and the close-up in Figure 1d&lt;/a&gt;. The cryogenic transmission electron microscopy images show long, narrow fibers in the acidic sample. In the close-up, you can see the twist. Small-angle X-ray scattering gave the team a second check on shape across the solution. A long-cylinder model fit the acidic sample, while the data for the base form of semaglutide at pH 8 supported micelles.&lt;/p&gt;

&lt;p&gt;There’s a reason I’d keep imaging in the plan even if two spectra look similar. In an &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC12152837/" rel="noopener noreferrer"&gt;earlier semaglutide study&lt;/a&gt;, the aged sample still had a helical CD signature, yet the researchers found a small population of short fibrils alongside the micelles. CD is good at showing when the overall structure has shifted. If a small population of fibers would change your formulation decision, it’s worth looking for those fibers directly.&lt;/p&gt;

&lt;h2&gt;
  
  
  Can CD help you choose a better formulation?
&lt;/h2&gt;

&lt;p&gt;A &lt;a href="https://doi.org/10.1016/j.ijpharm.2019.118923" rel="noopener noreferrer"&gt;study of the GLP-1-like peptide G48&lt;/a&gt; took that next step. The researchers tested whether adding polysorbate 80 would help G48 keep its structure under conditions that caused it to aggregate. Their Chirascan Plus spectra showed that G48 retained its helical shape with the additive at all three pH values tested.&lt;/p&gt;

&lt;p&gt;The result I’d want beside those spectra is &lt;a href="https://discovery.ucl.ac.uk/10087844/1/Williams%20IJP-D-19-01906%20accepted%20MS.pdf" rel="noopener noreferrer"&gt;the 72-hour comparison in Figure 7&lt;/a&gt;. Without a stabilizer, the team found no soluble monomer left at any of the three pH values. With polysorbate 80, they measured little to no loss of soluble monomer over the same period. That gives a formulation scientist two reasons to advance that condition for G48. The peptide kept its helical structure, and it stayed in solution as individual molecules.&lt;/p&gt;

&lt;h2&gt;
  
  
  Which samples would I send for imaging?
&lt;/h2&gt;

&lt;p&gt;Suppose two formulations start with the same spectrum, but only one develops a broad dip near 216 nm during storage. I’d repeat that comparison with independently prepared samples, the same peptide concentration and a matching blank for each formulation. I’d also check for cloudiness because &lt;a href="https://doi.org/10.1002/pro.70066" rel="noopener noreferrer"&gt;light scattered by particles can distort a CD spectrum&lt;/a&gt;.&lt;/p&gt;

&lt;p&gt;This is where I see a place for Chirascan in a formulation lab. Three formulations, four storage time points and two independent preparations already give you &lt;strong&gt;24 samples&lt;/strong&gt;, each with a buffer to account for. For a panel that size, Applied Photophysics reports that its automated &lt;a href="https://www.photophysics.com/product-pages/chirascan-q100/" rel="noopener noreferrer"&gt;Chirascan Q100 can measure 48 buffer–sample pairs in 24 hours&lt;/a&gt;. That makes it practical to keep the intermediate time points that a fresh-versus-aged comparison misses.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;I’d use Chirascan to choose a pair of samples for the microscope: the first time point with a reproducible change and the one immediately before it.&lt;/strong&gt; I’d include the matched formulation that held its original spectrum. Seeing fibers at day 40 tells you where the sample ended up. Knowing whether they were already present when the CD curves first diverged tells you where to focus the next round of formulation work.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>science</category>
    </item>
    <item>
      <title>AI Can Propose a Molecular Glue. What Evidence Shows It Works?</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Sat, 21 Nov 2026 22:40:53 +0000</pubDate>
      <link>https://dev.to/dessygil/ai-can-propose-a-molecular-glue-what-evidence-shows-it-works-2h7c</link>
      <guid>https://dev.to/dessygil/ai-can-propose-a-molecular-glue-what-evidence-shows-it-works-2h7c</guid>
      <description>&lt;p&gt;A compound binds a protein called 14-3-3 with an affinity of about 0.9 µM. Would you advance it as a molecular glue? I’d want to know what happened to the second protein.&lt;/p&gt;

&lt;p&gt;That number comes from a &lt;a href="https://doi.org/10.1038/s41419-025-08150-6" rel="noopener noreferrer"&gt;study that used Nicoya OpenSPR to measure lomitapide binding to 14-3-3ζ&lt;/a&gt;. The researchers were looking for compounds that could &lt;em&gt;disrupt&lt;/em&gt; its interaction with a partner called BAD. If my goal were to hold two proteins together, that same binding result would leave the most important question open.&lt;/p&gt;

&lt;p&gt;It’s a question worth asking as AI enters glue discovery. In their &lt;a href="https://www.drugdiscoverychemistry.com/europe/degraders-molecular-glues" rel="noopener noreferrer"&gt;November 11–12 conference abstract for Drug Discovery Chemistry Europe&lt;/a&gt;, Rapafusyn and Ternary Therapeutics described using AI models and compound libraries to design non-degrading glues for FKBP12 and TRAF2. That’s the companies’ account of their work. For a peer-reviewed example of how to test a glue, I’d start with a different member of the 14-3-3 family.&lt;/p&gt;

&lt;h2&gt;
  
  
  Does the compound help the second partner bind?
&lt;/h2&gt;

&lt;p&gt;In a &lt;a href="https://doi.org/10.1073/pnas.1220809110" rel="noopener noreferrer"&gt;study of the natural molecular glue fusicoccin A&lt;/a&gt;, researchers measured how tightly a phosphorylated piece of estrogen receptor alpha (ERα) bound to 14-3-3 proteins. Adding fusicoccin increased the peptide’s apparent affinity &lt;strong&gt;5- to 16-fold&lt;/strong&gt;, depending on the 14-3-3 variant. They measured that shift using fluorescence anisotropy. A crystal structure then showed fusicoccin sitting in a pocket where it touched both partners.&lt;/p&gt;

&lt;p&gt;That’s the comparison I’d want for an AI-designed candidate. How much of the second partner does it take to reach the same level of binding with and without the compound?&lt;/p&gt;

&lt;p&gt;For this pair, I’d test a surface plasmon resonance (SPR) assay that anchors the ERα peptide at one end, leaves its binding end exposed, and measures the larger 14-3-3 protein arriving at the surface. I’d first check compound solubility, match the solvent across samples, and confirm that the known glue produces a shift. If binding without compound is too weak to measure, I’d report the recruitment I can see and leave the fold change open.&lt;/p&gt;

&lt;h2&gt;
  
  
  What would I measure on Alto or Revo?
&lt;/h2&gt;

&lt;p&gt;One detail I like in the &lt;a href="https://doi.org/10.1038/s41592-024-02292-9" rel="noopener noreferrer"&gt;DART.2 paper in &lt;em&gt;Nature Methods&lt;/em&gt;&lt;/a&gt; is how clearly the authors defined the event they measured. On a &lt;strong&gt;Nicoya Alto-16&lt;/strong&gt;, their redesigned tether ligand was captured by the HaloTag protein &lt;strong&gt;45 times faster&lt;/strong&gt; than the earlier version. They presented the ligands with streptavidin and used an inactive capture protein as a reference. The 45-fold result belongs to that specific capture assay.&lt;/p&gt;

&lt;p&gt;For a glue, I’d use &lt;a href="https://nicoyalife.com/alto/" rel="noopener noreferrer"&gt;Alto’s 16 parallel sensors&lt;/a&gt; to compare partner recruitment with the candidate, the known glue, and solvent alone in the same run. For a smaller panel, &lt;a href="https://nicoyalife.com/revo/" rel="noopener noreferrer"&gt;Revo offers four or eight channels&lt;/a&gt;. Both systems automate serial dilutions on the cartridge, and Nicoya specifies a 2 µL minimum sample volume. When purified partner is scarce, I’d use that sample saving to repeat the comparison that decides whether a candidate advances.&lt;/p&gt;

&lt;h2&gt;
  
  
  What changed in the complex?
&lt;/h2&gt;

&lt;p&gt;&lt;a href="https://doi.org/10.1002/advs.202508543" rel="noopener noreferrer"&gt;Kay and colleagues&lt;/a&gt; examined the 14-3-3σ–ERα peptide complex using hydrogen–deuterium exchange mass spectrometry (HDX-MS). The technique tracks how readily backbone hydrogens exchange with deuterium in solution. Adding fusicoccin slowed exchange in several regions of 14-3-3σ. Its flexible tail, however, was already about &lt;strong&gt;85% exchanged at the first measurement, 10 minutes in&lt;/strong&gt;, and looked similar across conditions.&lt;/p&gt;

&lt;p&gt;That tail is where I’d try &lt;a href="https://nicoyalife.com/fasthdx/" rel="noopener noreferrer"&gt;FastHDX’s 50-millisecond labeling capability&lt;/a&gt;. There’s a practical reason to look earlier. In a &lt;a href="https://doi.org/10.1021/acs.analchem.2c05310" rel="noopener noreferrer"&gt;peer-reviewed study using a prototype co-developed by Applied Photophysics&lt;/a&gt;, millisecond measurements captured exchange in flexible loops of glycogen phosphorylase. I’d compare the preassembled ERα complexes with and without glue to see whether their tails differ before both have exchanged so extensively. Any difference would tell me where to investigate. I’d still need a cell experiment to connect it to function.&lt;/p&gt;

&lt;h2&gt;
  
  
  Does the cell response depend on the proposed interface?
&lt;/h2&gt;

&lt;p&gt;My favourite result is back in the &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC3670367/" rel="noopener noreferrer"&gt;ERα study’s cellular reporter experiment&lt;/a&gt;. At 1 nM estradiol, fusicoccin reduced the normal receptor’s transcriptional activity by &lt;strong&gt;more than 60%&lt;/strong&gt;. When the researchers removed the receptor’s last four amino acids, which form part of the binding interface, the reporter stopped responding to fusicoccin.&lt;/p&gt;

&lt;p&gt;That result would change which compound I advance. For the next round of AI design, I’d record three outcomes separately for every candidate. Did it bind one protein? How much did it change partner recruitment? Did the cellular effect depend on the proposed interface? A compound that binds tightly and pulls the partners apart is valuable data. Calling it a successful glue would teach the model the opposite of what the experiment showed.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>ai</category>
      <category>biotech</category>
      <category>science</category>
    </item>
    <item>
      <title>Plate-Based nanoDSF or Capillaries? A Buyer’s Guide to Automated Protein Stability Screening</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Sat, 21 Nov 2026 03:59:03 +0000</pubDate>
      <link>https://dev.to/dessygil/plate-based-nanodsf-or-capillaries-a-buyers-guide-to-automated-protein-stability-screening-1kek</link>
      <guid>https://dev.to/dessygil/plate-based-nanodsf-or-capillaries-a-buyers-guide-to-automated-protein-stability-screening-1kek</guid>
      <description>&lt;p&gt;Eight protein variants in six buffers gives you 48 measurements. Run each one twice and you’re at 96. Try two salt concentrations and you’re at &lt;strong&gt;192 measurements before adding a blank or reference&lt;/strong&gt;. You’re still working with the same eight proteins.&lt;/p&gt;

&lt;p&gt;That’s why I’d choose Nicoya’s &lt;a href="https://nicoyalife.com/supr-dsf/" rel="noopener noreferrer"&gt;SUPR-DSF&lt;/a&gt; for a lab running stability screens every week. Those 192 measurements occupy half of one standard 384-well plate. A liquid handler can prepare that plate, the instrument can read it directly, and the team can carry the same well map into its analysis. That last part becomes especially valuable when you want a model to learn from the experiment and suggest what to test next.&lt;/p&gt;

&lt;h2&gt;
  
  
  The plate your liquid handler fills is the plate your instrument reads
&lt;/h2&gt;

&lt;p&gt;You can start with a multichannel pipette. When the workload grows, a liquid handler can dispense into the same type of 384-well qPCR plate. Seal it and load it into SUPR-DSF. The sample your liquid handler dispensed into B7 is still in B7 when you open its unfolding curve.&lt;/p&gt;

&lt;p&gt;With individual Prometheus Panta capillaries, each prepared sample goes into a glass capillary and each capillary is positioned on the tray. The &lt;a href="https://support.nanotempertech.com/hc/en-us/articles/17986268452881-Prometheus-Panta-user-manual" rel="noopener noreferrer"&gt;Panta user manual&lt;/a&gt; specifies up to 48 individual capillaries per load. Our eight-variant example would fill four manual loads before controls.&lt;/p&gt;

&lt;p&gt;There’s a concrete example of how easily the plate workflow extends to automation. In a &lt;a href="https://photophysics.com/knowledge-hub/statistical-repeatability-of-tm-values-highlights-utility-of-protein-stability-screening-automation/" rel="noopener noreferrer"&gt;manufacturer study using SUPR-DSF&lt;/a&gt;, a Dragonfly liquid handler dispensed lysozyme into plates. After sealing, a PlateCrane moved each plate from a stack to the reader and returned it when the run finished. The setup measured &lt;strong&gt;16 plates in 26 hours&lt;/strong&gt;. Across &lt;strong&gt;6,096 repeats of the same protein&lt;/strong&gt;, the apparent melting temperature (&lt;em&gt;Tm&lt;/em&gt;) had a standard deviation of &lt;strong&gt;0.14 °C&lt;/strong&gt;.&lt;/p&gt;

&lt;p&gt;That’s the test I’d borrow for a demo. Put your own reference protein across two plates and run them through the setup you plan to use. If a half-degree improvement would change which variant you advance, you’ll know how that compares with the variation in your own experiment.&lt;/p&gt;

&lt;h2&gt;
  
  
  The consumable savings start well before the plate is full
&lt;/h2&gt;

&lt;p&gt;I budget about &lt;strong&gt;US$13 on average for a compatible 384-well qPCR plate and optical seal together&lt;/strong&gt;. A full plate works out to &lt;strong&gt;3.4 cents per measurement&lt;/strong&gt;. For the capillary comparison, I used &lt;a href="https://www.fishersci.com/shop/products/prometheus-nt-48-nanodsf-grade/NC1187355" rel="noopener noreferrer"&gt;Fisher Scientific’s U.S. listing of $404.25 for 400 Panta-compatible standard capillaries&lt;/a&gt;, or about $1.01 per measurement.&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Measurements&lt;/th&gt;
&lt;th&gt;SUPR-DSF plate and seal&lt;/th&gt;
&lt;th&gt;Plate cost per measurement&lt;/th&gt;
&lt;th&gt;Individual capillaries used&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;48&lt;/td&gt;
&lt;td&gt;$13.00&lt;/td&gt;
&lt;td&gt;27.1¢&lt;/td&gt;
&lt;td&gt;$48.51&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;96&lt;/td&gt;
&lt;td&gt;$13.00&lt;/td&gt;
&lt;td&gt;13.5¢&lt;/td&gt;
&lt;td&gt;$97.02&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;192&lt;/td&gt;
&lt;td&gt;$13.00&lt;/td&gt;
&lt;td&gt;6.8¢&lt;/td&gt;
&lt;td&gt;$194.04&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;384&lt;/td&gt;
&lt;td&gt;$13.00&lt;/td&gt;
&lt;td&gt;3.4¢&lt;/td&gt;
&lt;td&gt;$388.08&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;Even if you measure the original 48 conditions &lt;strong&gt;just once&lt;/strong&gt;, that’s about &lt;strong&gt;$36 saved on sample holders&lt;/strong&gt; at these prices. Run them in duplicate and the difference is about &lt;strong&gt;$84 per screen&lt;/strong&gt;, or &lt;strong&gt;$4,200 over 50 screens&lt;/strong&gt;. Actual savings depend on your supplier pricing.&lt;/p&gt;

&lt;p&gt;What I like at the bench is simpler. Once the plate is open, adding reference wells or another replicate for a difficult sample carries the same plate-and-seal cost.&lt;/p&gt;

&lt;h2&gt;
  
  
  What should an AI model learn from a stability screen?
&lt;/h2&gt;

&lt;p&gt;Ginkgo Bioworks offers a real example. In its &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC12674332/" rel="noopener noreferrer"&gt;peer-reviewed PROPHET-Ab study&lt;/a&gt;, the team used SUPR-DSF for the thermal-stability arm of a project spanning &lt;strong&gt;246 antibodies and 10 developability assays&lt;/strong&gt;. The thermal measurements used &lt;strong&gt;10 µL per well at 0.25 mg/mL&lt;/strong&gt;, or &lt;strong&gt;2.5 µg of antibody per well&lt;/strong&gt;. The researchers combined assay results to train a machine-learning model that scored how closely an antibody’s profile resembled those of approved antibodies.&lt;/p&gt;

&lt;p&gt;For a formulation team, I’d use the same ability to connect a sample to its measurements, but give the model a more immediate job: &lt;strong&gt;choose the next set of buffers worth making&lt;/strong&gt;.&lt;/p&gt;

&lt;p&gt;Consider what happened in a &lt;a href="https://www.photophysics.com/knowledge-hub/finding-formulations-faster-with-supr-dsf/" rel="noopener noreferrer"&gt;SUPR-DSF screen of infliximab across 96 buffers&lt;/a&gt;. All 96 conditions fit in triplicate on one plate. The buffer the team selected raised the antibody’s first unfolding transition by &lt;strong&gt;2.3 °C&lt;/strong&gt; and its second by &lt;strong&gt;1.3 °C&lt;/strong&gt; relative to the control. Other buffers pushed the second transition higher. A model trained only to maximize that later peak would have favoured a different formulation.&lt;/p&gt;

&lt;p&gt;Here’s how I’d set up the next round. I’d join each well’s protein ID, buffer, pH, salt concentration and replicate number to the &lt;a href="https://photophysics.com/faqs/methods-techniques/supr-dsf-faqs/" rel="noopener noreferrer"&gt;raw curves and fitted results that SUPR-Suite exports as CSV&lt;/a&gt;. I’d keep both transitions where they appear. Then I’d ask the model to suggest conditions likely to improve the first transition while preserving the second. The liquid handler could prepare those suggestions alongside the original reference, ready to test on the next plate. That gives the team a prediction it can check with fresh data.&lt;/p&gt;

&lt;h2&gt;
  
  
  When two buffers have similar melting temperatures
&lt;/h2&gt;

&lt;p&gt;Sometimes the better question is what happens when the protein cools. On SUPR-DSF, &lt;strong&gt;modulated scanning fluorimetry (MSF)&lt;/strong&gt; uses heating and cooling cycles to track when the protein’s natural fluorescence stops returning to its starting profile. A capillary platform such as Panta can use &lt;strong&gt;dynamic light scattering (DLS)&lt;/strong&gt; to follow changes in particle size during heating. Those measurements tell you different things about the sample.&lt;/p&gt;

&lt;p&gt;In &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/04/MM-0102_MSF_v10.pdf" rel="noopener noreferrer"&gt;Nicoya’s human IgG experiment&lt;/a&gt;, SUPR-DSF detected the onset of incomplete fluorescence recovery at &lt;strong&gt;63.7 °C&lt;/strong&gt;. A separate DLS experiment on a DynaPro instrument detected aggregation onset at &lt;strong&gt;70.3 °C&lt;/strong&gt;. For that antibody, the fluorescence picked up a lasting effect of heating several degrees before the sizing experiment flagged particle growth. If two buffers look equally good on melting temperature, recovery gives me another measured reason to favour one for follow-up.&lt;/p&gt;

&lt;h2&gt;
  
  
  Where I’d put the budget
&lt;/h2&gt;

&lt;p&gt;&lt;strong&gt;For a lab building an automated, AI-assisted protein stability workflow, I’d put SUPR-DSF on the bench.&lt;/strong&gt; The same plate format works for an experiment you pipette today and a stack of experiments you automate later. The consumable cost makes it practical to keep the repeats and controls, and the full fluorescence curves give the analysis team something to revisit when a single melting temperature hides a trade-off.&lt;/p&gt;

&lt;p&gt;I’d use the first plate to find promising conditions, the next to test the model’s suggestions against the same references, and fresh aliquots of the finalists to check recovery. That’s where the efficiency pays off. By the time the team commits its next batch of protein, it has measured why one formulation deserves it.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
    </item>
    <item>
      <title>SPR or BLI for AI-Designed Proteins? Why I’d Start With Alto</title>
      <dc:creator>Desmond Gilmour</dc:creator>
      <pubDate>Sat, 21 Nov 2026 03:32:46 +0000</pubDate>
      <link>https://dev.to/dessygil/spr-or-bli-for-ai-designed-proteins-why-id-start-with-alto-4pbh</link>
      <guid>https://dev.to/dessygil/spr-or-bli-for-ai-designed-proteins-why-id-start-with-alto-4pbh</guid>
      <description>&lt;p&gt;Suppose 12 AI-designed proteins arrive on Monday and your team can afford to make more of three. By Friday, you need to know which three. You also need enough of the most promising one left to check whether its binding holds up when you change the experiment.&lt;/p&gt;

&lt;p&gt;For that lab, I’d start with &lt;strong&gt;&lt;a href="https://nicoyalife.com/alto/" rel="noopener noreferrer"&gt;Nicoya Alto digital SPR&lt;/a&gt;&lt;/strong&gt;. It offers much of the ease that makes biolayer interferometry (BLI) appealing, with the real-time binding data of surface plasmon resonance (SPR). The feature that tips the decision for me is simple. You load the starting sample, and Alto makes the serial dilutions on its cartridge. In a &lt;a href="https://nicoyalife.com/resources/characterization-of-fc-gamma-receptors-alto-spr-bli/" rel="noopener noreferrer"&gt;published Nicoya assay&lt;/a&gt;, &lt;strong&gt;2 µL of antibody stock was enough for a five-concentration binding series&lt;/strong&gt;.&lt;/p&gt;

&lt;h2&gt;
  
  
  What did those 2 µL actually buy?
&lt;/h2&gt;

&lt;p&gt;Nicoya tested how a mouse antibody bound to an Fc receptor. On Alto, the team loaded 2 µL of a 300 nM antibody stock per sample well. The cartridge prepared five concentrations spanning 1.23 to 100 nM. For the 150 kDa antibody in that experiment, that works out to &lt;strong&gt;about 90 nanograms of starting antibody per loaded well&lt;/strong&gt;.&lt;/p&gt;

&lt;p&gt;A contract lab measured the same interaction by BLI. Here’s what Nicoya reported in its &lt;a href="https://nicoyalife.com/wp-content/uploads/2026/01/Characterization-of-Fc-Gamma-Receptor-and-IgG-Interactions-using-Alto%E2%84%A2-Comparison-to-BLI.pdf" rel="noopener noreferrer"&gt;side-by-side comparison&lt;/a&gt;.&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;What the team measured&lt;/th&gt;
&lt;th&gt;Alto digital SPR&lt;/th&gt;
&lt;th&gt;BLI workflow&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;Binding affinity using the same one-site fit&lt;/td&gt;
&lt;td&gt;8.27 nM&lt;/td&gt;
&lt;td&gt;9.36 nM&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;Hands-on operator time&lt;/td&gt;
&lt;td&gt;28 minutes&lt;/td&gt;
&lt;td&gt;66 minutes&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;The BLI estimate was 7.67 nM when the fit accounted for how quickly antibody reached the sensor. Both methods put the interaction in a similar affinity range. What would change my week is the &lt;strong&gt;38 minutes of hands-on time saved in this assay&lt;/strong&gt;. Nicoya attributed 25 minutes of savings to dilution preparation alone. If my lab receives a fresh batch of designs every Monday, that’s the step I’d want the instrument doing for me.&lt;/p&gt;

&lt;h2&gt;
  
  
  Both workflows can be automated. Where does the work happen?
&lt;/h2&gt;

&lt;p&gt;BLI has a real strength when a lab already has plates of diluted samples ready to run. The &lt;strong&gt;&lt;a href="https://www.sartorius.com/products/biolayer-interferometry/octet-rh96" rel="noopener noreferrer"&gt;Sartorius Octet RH96&lt;/a&gt;&lt;/strong&gt; supports robotic loading of plates and biosensor trays, and samples can be recovered afterward. Sartorius lists 40–80 µL per well in its tilted 384-well plate format. That’s diluted well volume, so I’d compare the micrograms taken from the original stock across the whole experiment.&lt;/p&gt;

&lt;p&gt;Alto is the better fit for me when the lab starts with &lt;strong&gt;small tubes of concentrated protein&lt;/strong&gt; and needs binding curves at several concentrations. Its 16-channel cartridge handles the dilution series and moves the samples and buffers to the sensors. With the &lt;strong&gt;&lt;a href="https://nicoyalife.com/alto-automation-suite/" rel="noopener noreferrer"&gt;Alto Automation Suite&lt;/a&gt;&lt;/strong&gt;, an Opentrons Flex can prepare cartridges, and a lab’s scheduling software can check instrument status, start runs and retrieve results. The next batch can be in preparation while the current one is collecting data.&lt;/p&gt;

&lt;p&gt;That difference becomes clearer when you plan a real workload. &lt;strong&gt;Twenty-four designs at five concentrations in duplicate means 240 concentration measurements&lt;/strong&gt; before extra controls or reruns. My throughput question would be how many of those 24 designs get a result the team can use by Friday, and how much protein it takes to get there.&lt;/p&gt;

&lt;h2&gt;
  
  
  What does SPR-quality data look like?
&lt;/h2&gt;

&lt;p&gt;In a &lt;a href="https://nicoyalife.com/resources/conventional-vs-digital-spr-comparison-study/" rel="noopener noreferrer"&gt;separate Nicoya study comparing Alto with conventional SPR&lt;/a&gt;, researchers measured an antibody fragment binding to green fluorescent protein. They reported affinities of &lt;strong&gt;8.6 nM on Alto and 10.0 nM on conventional SPR&lt;/strong&gt;. Figure 3 shows the measured curves at five concentrations alongside the fits. You can see how binding builds while the sample is present and how quickly the complex comes apart afterward. That’s the evidence I’d want behind a number going back to a design team.&lt;/p&gt;

&lt;p&gt;There’s a good reason to save protein for a second look. In the &lt;a href="https://pmc.ncbi.nlm.nih.gov/articles/PMC12507698/" rel="noopener noreferrer"&gt;BindCraft study&lt;/a&gt;, 13 of 53 designs showed binding to PD-1 in a BLI screen that included an unrelated protein as a specificity control. The strongest hit released so slowly, and benefited so much from its two binding arms, that the authors reported an &lt;strong&gt;apparent affinity tighter than 1 nM&lt;/strong&gt;. That less-than sign belongs in the dataset. Entering &lt;code&gt;1 nM&lt;/code&gt; would give the next model a number nobody measured.&lt;/p&gt;

&lt;p&gt;For a finalist like that, I’d use some of the protein saved on the first run to repeat the measurement with less target on the sensor and more time to watch it release. On a crowded surface, a molecule can detach and &lt;a href="https://doi.org/10.1016/j.ab.2023.115085" rel="noopener noreferrer"&gt;catch a neighboring target&lt;/a&gt;, making it appear to stay bound longer. If the ranking holds up on the second surface, I have a stronger reason to make more of that design.&lt;/p&gt;

&lt;p&gt;For smaller batches, &lt;strong&gt;&lt;a href="https://nicoyalife.com/revo/" rel="noopener noreferrer"&gt;Revo 4 and Revo 8&lt;/a&gt;&lt;/strong&gt; bring the same practical idea to a four- or eight-channel benchtop system, with automated on-cartridge dilutions and a 2 µL minimum sample input. Alto is where I’d start for a team running recurring design cycles and building toward a connected, automated lab.&lt;/p&gt;

&lt;h2&gt;
  
  
  The experiment I’d buy Alto to run
&lt;/h2&gt;

&lt;p&gt;I’d put one real batch in the demo, including a known binder, an unrelated control and a candidate the team can barely spare. Then I’d ask to see the curves, the hands-on time and what’s left in that last tube.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;That last tube is why I’d choose Alto for this work.&lt;/strong&gt; A first screen can tell me which design looks best. If automated dilutions leave enough of it to change the surface, repeat the measurement and see whether it still comes out on top, I can tell the design team &lt;em&gt;why&lt;/em&gt; it deserves another round. That’s a better starting point for the next set of AI-designed proteins.&lt;/p&gt;




&lt;p&gt;Desmond Gilmour&lt;/p&gt;

&lt;p&gt;Email: &lt;a href="mailto:dgilmour@nicoyalife.com"&gt;dgilmour@nicoyalife.com&lt;/a&gt;&lt;/p&gt;

&lt;p&gt;Phone: +1 519-546-9876&lt;/p&gt;

&lt;p&gt;I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.&lt;/p&gt;

</description>
      <category>ai</category>
      <category>biotech</category>
      <category>science</category>
    </item>
  </channel>
</rss>
