<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <channel>
    <title>DEV Community: Safe &amp; Secure Safety Systems Group</title>
    <description>The latest articles on DEV Community by Safe &amp; Secure Safety Systems Group (@sss-fire).</description>
    <link>https://dev.to/sss-fire</link>
    <image>
      <url>https://media2.dev.to/dynamic/image/width=90,height=90,fit=cover,gravity=auto,format=auto/https:%2F%2Fdev-to-uploads.s3.us-east-2.amazonaws.com%2Fuploads%2Fuser%2Fprofile_image%2F4114522%2F8d0d1c14-a689-4339-b85d-2040558d51a8.png</url>
      <title>DEV Community: Safe &amp; Secure Safety Systems Group</title>
      <link>https://dev.to/sss-fire</link>
    </image>
    <atom:link rel="self" type="application/rss+xml" href="https://dev.to/feed/sss-fire"/>
    <language>en</language>
    <item>
      <title>Fire Door Hardware and Panic Bars: What Actually Makes a Fire Rated Door Perform</title>
      <dc:creator>Safe &amp; Secure Safety Systems Group</dc:creator>
      <pubDate>Fri, 18 Sep 2026 17:46:52 +0000</pubDate>
      <link>https://dev.to/sss-fire/fire-door-hardware-and-panic-bars-what-actually-makes-a-fire-rated-door-perform-3ep4</link>
      <guid>https://dev.to/sss-fire/fire-door-hardware-and-panic-bars-what-actually-makes-a-fire-rated-door-perform-3ep4</guid>
      <description>&lt;p&gt;A fire rating on a door is really a rating on an assembly — the leaf, the frame, the seals, the hinges, and the hardware, all tested together. It's easy to focus on the door itself and treat the hardware as a secondary detail. In practice, the hardware is often exactly where a compliant-looking door stops actually performing as rated.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;A Rating Doesn't Transfer Automatically to Swapped Hardware&lt;/strong&gt;&lt;br&gt;
If a door leaf and frame were tested and certified as part of a specific assembly, swapping in a different handle, hinge, or closer — even one that looks equivalent — can invalidate that certification. The rating applies to the tested combination, not to the door leaf in isolation. This is one of the more common gaps found during post-handover audits: a door that was correctly specified at installation, with hardware quietly replaced or upgraded later by someone unaware of the compliance implications.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Panic Bars Exist for a Specific Reason&lt;/strong&gt;&lt;br&gt;
Panic hardware — the horizontal bar that releases a door with a single push — is required on doors along certain escape routes specifically because it has to work under stress, in the dark, for someone who may be moving quickly and not thinking clearly about door mechanics. A door with a standard handle or a lock requiring a key or code defeats the purpose of a fire escape route if people can't get through it quickly during an actual evacuation.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Self-Closers Are the Detail Most Often Defeated&lt;/strong&gt;&lt;br&gt;
A fire rated door only works if it's actually closed. Self-closing hardware is designed to bring the door shut automatically after each use, but this is also one of the easiest features to disable in practice — propped open with a wedge, closer arm disconnected because it's "annoying," or simply not maintained until it stops functioning. Every one of these situations quietly removes the door's fire performance without anyone necessarily realizing it.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Intumescent Seals Do Their Job Invisibly Until They Don't&lt;/strong&gt;&lt;br&gt;
Intumescent seals around a fire door's frame expand under heat to close gaps and block smoke and flame from passing around the edges of the door. They look like an unremarkable strip of material during normal use, which is exactly why damage or missing sections often go unnoticed — there's no visible sign anything's wrong until the door is actually tested by a real fire.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;What This Means at Inspection and Maintenance Stage&lt;/strong&gt;&lt;br&gt;
Checking a fire rated door properly means checking the whole assembly, not just confirming a door exists in the opening: hardware matches the certified specification, self-closers function correctly and aren't propped open, and seals are intact around the full perimeter of the frame.&lt;/p&gt;

&lt;p&gt;Safe &amp;amp; Secure Safety Systems Group supplies and installs fire rated doors and compliant hardware across the UAE, specified as a complete tested assembly rather than a door leaf on its own.&lt;/p&gt;

&lt;p&gt;More on fire door hardware and panic bar requirements: &lt;a href="https://sss-fire.com/fire-door-hardware-panic-bars-uae/" rel="noopener noreferrer"&gt;&lt;/a&gt;&lt;br&gt;
Fire rated door solutions: &lt;a href="https://sss-fire.com/fire-rated-door-uae/" rel="noopener noreferrer"&gt;&lt;/a&gt;&lt;/p&gt;

</description>
      <category>buildingcodes</category>
      <category>facilities</category>
      <category>firesafety</category>
      <category>uae</category>
    </item>
    <item>
      <title>Fire Curtain Systems: Compartmentation for Atriums and Open-Plan Buildings</title>
      <dc:creator>Safe &amp; Secure Safety Systems Group</dc:creator>
      <pubDate>Fri, 18 Sep 2026 17:45:22 +0000</pubDate>
      <link>https://dev.to/sss-fire/fire-curtain-systems-compartmentation-for-atriums-and-open-plan-buildings-2omd</link>
      <guid>https://dev.to/sss-fire/fire-curtain-systems-compartmentation-for-atriums-and-open-plan-buildings-2omd</guid>
      <description>&lt;p&gt;Compartmentation is one of the oldest ideas in fire safety: contain a fire to the area it started in, and you buy time for everyone else in the building. The problem is that modern architecture — atriums, open-plan retail, glass-walled offices — increasingly works against this idea by design. Fire curtains exist specifically to solve that conflict.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Why Open-Plan Buildings Struggle With Compartmentation&lt;/strong&gt;&lt;br&gt;
Permanent walls are the simplest way to compartmentalize a building, but a lot of contemporary design deliberately avoids them. A mall atrium, a hotel lobby with a double-height ceiling, an open-plan office floor — all of these are built around uninterrupted sightlines and flow, which is exactly what compartmentation is supposed to prevent. Without some mechanism to close off these spaces during a fire, smoke and flame can move through them just as freely as people do during normal use.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;How Fire Curtains Actually Work&lt;/strong&gt;&lt;br&gt;
A fire curtain sits concealed above the ceiling line in normal conditions — completely invisible to the space's everyday use — and deploys automatically when triggered by the building's fire detection system. Once deployed, it forms a continuous barrier that contains smoke and fire to one side, buying time for evacuation and limiting how far a fire can spread before suppression systems or fire crews respond.&lt;/p&gt;

&lt;p&gt;This is the key advantage over permanent walls: a fire curtain lets architects keep the open, connected feel of a space during normal operation while still providing genuine compartmentation when it matters.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Where Fire Curtains Get Used&lt;/strong&gt;&lt;br&gt;
Atriums, escalator openings between floors, large glazed openings, and transitions between different occupancy types within the same building (a retail floor connecting to a parking structure, for example) are common applications. Anywhere a permanent wall isn't architecturally acceptable but compartmentation is still required by code, a fire curtain is often the practical answer.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Integration Matters More Than the Curtain Itself&lt;/strong&gt;&lt;br&gt;
A fire curtain is only as good as its trigger. It needs to be integrated with the building's fire detection and alarm system so it deploys automatically and promptly when a fire is detected — not manually activated, and not deployed on a delay that defeats the purpose. This integration is where a lot of installations get evaluated during Civil Defence approval, because a compartmentation system that doesn't deploy reliably isn't meaningfully different from having no compartmentation at all.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;How This Fits With Fire Rated Doors&lt;/strong&gt;&lt;br&gt;
Fire curtains and fire rated doors solve the same underlying problem — containing fire spread — in different contexts. Doors handle openings in permanent walls; curtains handle open spans where a wall was never going to exist in the first place. A building's overall compartmentation strategy usually needs both, assessed together rather than as separate, unrelated line items.&lt;/p&gt;

&lt;p&gt;Safe &amp;amp; Secure Safety Systems Group works on compartmentation strategy across the UAE, including fire curtain systems for open-plan and atrium spaces alongside fire-rated door solutions.&lt;/p&gt;

&lt;p&gt;More on fire curtain systems: &lt;a href="https://sss-fire.com/fire-curtain-systems-uae/" rel="noopener noreferrer"&gt;&lt;/a&gt;&lt;br&gt;
Fire rated door solutions: &lt;a href="https://sss-fire.com/fire-rated-door-uae/" rel="noopener noreferrer"&gt;&lt;/a&gt;&lt;/p&gt;

</description>
    </item>
    <item>
      <title>Parking Garage Fire Safety: The EV and Ventilation Risk Most Buildings Miss</title>
      <dc:creator>Safe &amp; Secure Safety Systems Group</dc:creator>
      <pubDate>Thu, 17 Sep 2026 17:36:12 +0000</pubDate>
      <link>https://dev.to/sss-fire/parking-garage-fire-safety-the-ev-and-ventilation-risk-most-buildings-miss-eh0</link>
      <guid>https://dev.to/sss-fire/parking-garage-fire-safety-the-ev-and-ventilation-risk-most-buildings-miss-eh0</guid>
      <description>&lt;p&gt;Parking garages get treated as low-priority fire safety zones more often than they should. They're not occupied continuously, they don't have the fire load of a warehouse, and for a long time that assumption was mostly fine. Two things have changed it: the rise of EV charging infrastructure in basements and garages, and the fact that ventilation design in enclosed parking structures is doing more fire-safety work than most people realize.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Vehicle Fires Aren't a Uniform Risk Category&lt;/strong&gt;&lt;br&gt;
A conventional vehicle fire and a lithium-ion EV battery fire behave differently enough that treating them as the same risk is a mistake. Conventional fuel fires burn hot but predictably. EV battery fires are driven by thermal runaway — a self-sustaining chemical reaction inside the battery cells that can keep the fire reigniting even after visible flames appear extinguished, and that releases its own toxic and flammable gases as part of the process.&lt;/p&gt;

&lt;p&gt;This matters directly for parking garages because EV charging bays are increasingly being installed in exactly the kind of enclosed, poorly ventilated spaces where a self-reigniting fire with its own gas byproduct is hardest to manage.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Ventilation Is Part of the Fire Strategy, Not a Separate System&lt;/strong&gt;&lt;br&gt;
In an enclosed parking structure, mechanical ventilation isn't just there for air quality during normal operation — it's a core part of how the building manages smoke and gas buildup during a fire event. If ventilation design wasn't planned with EV charging risk specifically in mind, a garage that seems adequately ventilated for exhaust fumes may not be adequately designed for the gas release profile of a battery fire.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Detection Needs to Match the Actual Risk Profile&lt;/strong&gt;&lt;br&gt;
Standard garage smoke detection, tuned for exhaust fumes and conventional combustion, doesn't necessarily respond the same way to an EV battery fire's early signature. Charging bay areas benefit from detection systems and placement specifically considered for this risk, rather than assuming existing garage-wide detection automatically covers it.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Spacing and Separation Decisions Happen at Design Stage&lt;/strong&gt;&lt;br&gt;
Where EV charging bays are physically located relative to building exits, structural columns, and other parked vehicles affects both how a fire could spread and how contained it stays if it does. This isn't something that gets fixed easily after installation — it needs to be part of the original design, not an afterthought once charging infrastructure gets added to an existing garage.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;What This Means for Property Owners&lt;/strong&gt;&lt;br&gt;
If your building has EV charging installed or planned in an enclosed parking structure, this deserves a specific conversation with your fire safety provider rather than an assumption that the existing garage fire system already accounts for it.&lt;/p&gt;

&lt;p&gt;Safe &amp;amp; Secure Safety Systems Group works on fire fighting and detection system design for parking structures across the UAE, including EV charging bay risk considerations.&lt;/p&gt;

&lt;p&gt;More on parking garage fire safety: &lt;a href="https://sss-fire.com/parking-garage-fire-safety-uae/" rel="noopener noreferrer"&gt;&lt;/a&gt;&lt;br&gt;
Fire fighting installation services: &lt;a href="https://sss-fire.com/fire-fighting-installation-uae/" rel="noopener noreferrer"&gt;&lt;/a&gt;&lt;/p&gt;

</description>
      <category>uae</category>
      <category>firesafety</category>
      <category>parkinggarage</category>
    </item>
    <item>
      <title>Shopping Mall Fire Safety: Why Open-Plan Retail Needs a Different Detection Strategy</title>
      <dc:creator>Safe &amp; Secure Safety Systems Group</dc:creator>
      <pubDate>Thu, 17 Sep 2026 17:34:28 +0000</pubDate>
      <link>https://dev.to/sss-fire/shopping-mall-fire-safety-why-open-plan-retail-needs-a-different-detection-strategy-2mbf</link>
      <guid>https://dev.to/sss-fire/shopping-mall-fire-safety-why-open-plan-retail-needs-a-different-detection-strategy-2mbf</guid>
      <description>&lt;p&gt;Shopping malls break most of the assumptions standard fire detection is designed around. A typical commercial building has enclosed rooms, defined ceiling heights, and a manageable number of distinct occupants. A mall has soaring atriums, open-plan retail floors that flow into each other, dozens of independent tenants, and smoke that can travel freely across zones that were never meant to be treated as one continuous space.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;High Ceilings Change How Smoke Behaves&lt;/strong&gt;&lt;br&gt;
Standard smoke detectors are calibrated for typical ceiling heights, where smoke rises and pools in a fairly predictable way. In a mall atrium that might be three or four stories tall, smoke stratifies — it cools and spreads laterally before it ever reaches a ceiling-mounted detector. This is why many malls rely on aspirating smoke detection or beam detectors for large open volumes, rather than assuming standard point detectors will catch a fire early enough in that kind of space.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Multi-Tenant Buildings Need Coordinated Systems, Not Independent Ones&lt;/strong&gt;&lt;br&gt;
Every tenant in a mall — retail units, F&amp;amp;B outlets, anchor stores — technically operates its own space, but a fire doesn't respect lease boundaries. If each tenant's fire system is designed and maintained independently, with no coordination at the building level, you end up with gaps: a restaurant's kitchen suppression system that isn't integrated with the mall's central fire alarm, or a retail unit's fit-out that altered ceiling clearances without anyone updating the detection layout above it.&lt;/p&gt;

&lt;p&gt;A properly designed mall fire system treats the building as one coordinated network — central monitoring, zone-specific detection tuned to what's actually happening in that zone, and integration between individual tenant fit-outs and the base-building fire alarm control panel.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Smoke Management Isn't Optional in Large Open Spaces&lt;/strong&gt;&lt;br&gt;
Beyond detection, malls typically require active smoke management — systems that actively extract or control smoke movement to keep escape routes clear during an evacuation. In an open-plan retail environment, smoke doesn't just rise; it can travel horizontally across the entire floor plate if there's nothing designed to control that movement. This is a fundamentally different engineering problem than smoke management in a standard office building.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Retail Fit-Outs Are a Recurring Compliance Risk&lt;/strong&gt;&lt;br&gt;
Malls change constantly. Tenants come and go, units get renovated, layouts shift. Every one of these changes can affect the fire strategy that was originally approved for the building — a dropped ceiling that changes detector spacing requirements, a new kitchen that needs its own suppression system, a partition wall that alters smoke movement patterns. Mall FM teams that don't have a clear process for reviewing fire safety implications of every tenant fit-out are the ones most likely to discover a mismatch during an inspection rather than before one.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;What This Means for Facility Managers&lt;/strong&gt;&lt;br&gt;
If you're managing fire safety for a shopping mall, the base-building fire alarm control panel and central detection network need to be treated as a living system that gets reviewed every time a tenant space changes — not a fixed system that was correct once at handover.&lt;/p&gt;

&lt;p&gt;Safe &amp;amp; Secure Safety Systems Group works on fire alarm and detection systems for retail and mall environments across the UAE, including central panel coordination across multi-tenant buildings.&lt;/p&gt;

&lt;p&gt;More on shopping mall fire safety: &lt;a href="https://sss-fire.com/shopping-mall-fire-safety-uae/" rel="noopener noreferrer"&gt;&lt;/a&gt;&lt;br&gt;
Fire alarm control panel systems: &lt;a href="https://sss-fire.com/fire-alarm-control-panel-uae/" rel="noopener noreferrer"&gt;&lt;/a&gt;&lt;/p&gt;

</description>
      <category>uae</category>
      <category>facilities</category>
      <category>retail</category>
      <category>firesafety</category>
    </item>
    <item>
      <title>Fire NOC in the UAE: The Approval Steps Most People Skip</title>
      <dc:creator>Safe &amp; Secure Safety Systems Group</dc:creator>
      <pubDate>Tue, 15 Sep 2026 14:41:56 +0000</pubDate>
      <link>https://dev.to/sss-fire/fire-noc-in-the-uae-the-approval-steps-most-people-skip-hb2</link>
      <guid>https://dev.to/sss-fire/fire-noc-in-the-uae-the-approval-steps-most-people-skip-hb2</guid>
      <description>&lt;p&gt;If you're planning a new build, fit-out, or renovation in the UAE, the Civil Defence NOC (No Objection Certificate) process is usually where timelines slip — not because the fire system itself is complicated, but because the approval sequence gets done out of order.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;It's a Sequence, Not a Single Approval&lt;/strong&gt;&lt;br&gt;
A lot of people treat the NOC as one step at the end of construction. It's actually several steps, and skipping or reordering them is what turns a straightforward approval into a months-long delay.&lt;/p&gt;

&lt;ol&gt;
&lt;li&gt;&lt;p&gt;Design comes before installation.&lt;br&gt;
Fire alarm and suppression layouts need to be submitted and approved against Civil Defence standards before any equipment goes into the walls. Installing first and hoping it passes review is the single most common mistake — and it usually means ripping out and redoing work that didn't match the approved plan.&lt;/p&gt;&lt;/li&gt;
&lt;li&gt;&lt;p&gt;Installed systems have to match the approved drawings exactly.&lt;br&gt;
A relocated detector, a swapped panel model, a change nobody documented — any deviation from what was approved gets flagged during review, even if the change seems minor or like an improvement.&lt;/p&gt;&lt;/li&gt;
&lt;li&gt;&lt;p&gt;Inspection happens after full commissioning, not before.&lt;br&gt;
The site needs to be fully ready — systems installed, tested, and commissioned — before Civil Defence will schedule an inspection visit. Booking too early just means a failed inspection and a re-booking delay, which costs more time than waiting the extra few days to be genuinely ready.&lt;/p&gt;&lt;/li&gt;
&lt;li&gt;&lt;p&gt;Fit-out and fire system design need to stay coordinated.&lt;br&gt;
A common failure point: interior fit-out changes a space's layout after fire system design was already approved, and nobody updates the fire drawings to match. That mismatch gets caught at inspection — not before, when it would've been cheap to fix.&lt;/p&gt;&lt;/li&gt;
&lt;li&gt;&lt;p&gt;The NOC has an expiry.&lt;br&gt;
Getting approved once doesn't mean permanent coverage. Renewals and re-inspections are part of staying compliant, not a one-time formality you complete and forget.&lt;/p&gt;&lt;/li&gt;
&lt;/ol&gt;

&lt;p&gt;&lt;strong&gt;What Actually Speeds This Up&lt;/strong&gt;&lt;br&gt;
Projects move through NOC approval fastest when the fire safety contractor is involved at the design stage — not brought in after the fit-out is already finished and someone realizes the fire drawings no longer match reality.&lt;/p&gt;

&lt;p&gt;Safe &amp;amp; Secure Safety Systems Group supports Civil Defence approval across the UAE — from initial fire system design through installation, commissioning, and inspection sign-off.&lt;/p&gt;

&lt;p&gt;More on the approval process: &lt;a href="https://sss-fire.com/building-approvals-dubai-uae/" rel="noopener noreferrer"&gt;https://sss-fire.com/building-approvals-dubai-uae/&lt;/a&gt;&lt;/p&gt;

</description>
      <category>firesafety</category>
      <category>facilities</category>
      <category>uae</category>
    </item>
    <item>
      <title>Why Fire Alarm Systems Fail Compliance Checks (And How AMCs Prevent It)</title>
      <dc:creator>Safe &amp; Secure Safety Systems Group</dc:creator>
      <pubDate>Tue, 15 Sep 2026 14:40:11 +0000</pubDate>
      <link>https://dev.to/sss-fire/why-fire-alarm-systems-fail-compliance-checks-and-how-amcs-prevent-it-3l3g</link>
      <guid>https://dev.to/sss-fire/why-fire-alarm-systems-fail-compliance-checks-and-how-amcs-prevent-it-3l3g</guid>
      <description>&lt;p&gt;A fire alarm system passing inspection at handover doesn't mean it stays compliant. That's the part most property owners in the UAE don't realize until a follow-up inspection flags something — and by then it's usually a bigger fix than it needed to be.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;The System Doesn't Fail All at Once&lt;/strong&gt;&lt;br&gt;
Compliance failures are rarely dramatic. They're small, individually minor issues that stack up over months:&lt;/p&gt;

&lt;p&gt;A smoke detector drifts out of calibration and starts throwing false alarms — or worse, stops responding fast enough.&lt;br&gt;
A control panel logs a fault that nobody clears, so it just sits there, unresolved, until an inspector finds it.&lt;br&gt;
Sounders or bells lose volume or stop working entirely in one zone, and nobody notices because that zone has never had a real trigger event.&lt;br&gt;
Batteries in backup power supplies degrade quietly, and the system only reveals the problem during an actual power cut.&lt;/p&gt;

&lt;p&gt;None of these show up on a casual walkthrough. They show up during a proper test cycle, or during an emergency — and only one of those is a good time to find out.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Why "It Passed Inspection" Isn't the Same as "It's Compliant"&lt;/strong&gt;&lt;br&gt;
A Civil Defence approval certifies a system at a single point in time. It says the system met code on the day it was checked. It says nothing about whether the same system will still meet code a year or two later, because mechanical and electronic components don't stay static — they degrade, drift, and fail in ways that are only caught by scheduled testing.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Where AMCs Actually Fit In&lt;/strong&gt;&lt;br&gt;
An Annual Maintenance Contract isn't a support hotline for when something breaks. It's a scheduled cycle of testing and servicing — detectors, panels, sounders, batteries, wiring — so these small failures get caught during a routine visit instead of during an inspection or an actual fire. It also creates a documented service history, which matters when Civil Defence or insurance asks for proof of ongoing compliance rather than a one-time installation certificate.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;The Bottom Line&lt;/strong&gt;&lt;br&gt;
If your last fire alarm test was "sometime last year, I think," that's worth checking before your next inspection does it for you.&lt;/p&gt;

&lt;p&gt;Safe &amp;amp; Secure Safety Systems Group runs AMC contracts across the UAE covering fire alarm systems, suppression, sprinklers, and more — scheduled maintenance that keeps compliance current year over year.&lt;/p&gt;

&lt;p&gt;More on how AMC contracts work: &lt;a href="https://sss-fire.com/amc-fire-alarm-systems-uae/" rel="noopener noreferrer"&gt;https://sss-fire.com/amc-fire-alarm-systems-uae/&lt;/a&gt;&lt;/p&gt;

</description>
      <category>firesafety</category>
      <category>facilities</category>
      <category>uae</category>
    </item>