<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <channel>
    <title>DEV Community: Yves Wu</title>
    <description>The latest articles on DEV Community by Yves Wu (@weup_switches).</description>
    <link>https://dev.to/weup_switches</link>
    <image>
      <url>https://media2.dev.to/dynamic/image/width=90,height=90,fit=cover,gravity=auto,format=auto/https:%2F%2Fdev-to-uploads.s3.us-east-2.amazonaws.com%2Fuploads%2Fuser%2Fprofile_image%2F4269361%2F2201fec3-d088-4de2-9c6a-701d6f3131d1.jpg</url>
      <title>DEV Community: Yves Wu</title>
      <link>https://dev.to/weup_switches</link>
    </image>
    <atom:link rel="self" type="application/rss+xml" href="https://dev.to/feed/weup_switches"/>
    <language>en</language>
    <item>
      <title>Rocker switch cutouts, fuse holder sizes and inlets: 30x22 vs 19x13, 5x20 vs 6.3x32, C14 vs C20</title>
      <dc:creator>Yves Wu</dc:creator>
      <pubDate>Fri, 27 Nov 2026 16:35:44 +0000</pubDate>
      <link>https://dev.to/weup_switches/rocker-switch-cutouts-fuse-holder-sizes-and-inlets-30x22-vs-19x13-5x20-vs-63x32-c14-vs-c20-1j5</link>
      <guid>https://dev.to/weup_switches/rocker-switch-cutouts-fuse-holder-sizes-and-inlets-30x22-vs-19x13-5x20-vs-63x32-c14-vs-c20-1j5</guid>
      <description>&lt;p&gt;Three numbers decide whether a panel build fits on the first try: the cutout, the fuse holder size, and the inlet series. They are also the three that get ordered wrong most often, because the catalogue shows a photo of the front and says nothing about the panel.&lt;/p&gt;

&lt;h2&gt;
  
  
  Cutout: 30x22 vs 19x13
&lt;/h2&gt;

&lt;p&gt;The KCD-series numbers people quote are not the switch size. They are the &lt;strong&gt;panel hole&lt;/strong&gt;:&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Series&lt;/th&gt;
&lt;th&gt;Cutout&lt;/th&gt;
&lt;th&gt;Typical rating&lt;/th&gt;
&lt;th&gt;Bezel&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;KCD1&lt;/td&gt;
&lt;td&gt;19 x 13 mm&lt;/td&gt;
&lt;td&gt;6-10 A&lt;/td&gt;
&lt;td&gt;~21 x 15 mm&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;KCD4&lt;/td&gt;
&lt;td&gt;30 x 22 mm&lt;/td&gt;
&lt;td&gt;16-20 A&lt;/td&gt;
&lt;td&gt;~33 x 25 mm&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;Three things that go wrong even when the cutout is correct:&lt;/p&gt;

&lt;ol&gt;
&lt;li&gt;
&lt;strong&gt;Panel thickness.&lt;/strong&gt; Snap-in legs are moulded for roughly 0.8-3 mm. A 4 mm panel will not let the legs spring back and the switch sits proud; a 0.6 mm sheet flexes and the switch rocks in the hole. The fix is a screw-mount variant or a backing plate, not a bigger cutout.&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Tolerance.&lt;/strong&gt; Cut 30.0 x 22.0 +0.2/-0 mm. A laser-cut 29.8 mm hole will crack the retaining clips on first insertion, and that crack does not show until the switch is under load.&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;Corner radius.&lt;/strong&gt; The hole needs square corners with a small radius, not a punched round hole with filed flats. The bezel lip covers 1.5 mm per side; anything more and you see daylight.&lt;/li&gt;
&lt;/ol&gt;

&lt;p&gt;If you are replacing a switch in an existing panel, measure the hole, not the old switch. The old bezel tells you nothing about the cutout.&lt;/p&gt;

&lt;h2&gt;
  
  
  Fuse holders: 5x20 vs 6.3x32
&lt;/h2&gt;

&lt;p&gt;Both are cartridge fuses. The first number is the fuse, not the holder: 5 mm diameter by 20 mm long, or 6.3 mm by 32 mm.&lt;/p&gt;

&lt;ul&gt;
&lt;li&gt;
&lt;strong&gt;5x20&lt;/strong&gt; is the electronics size. Panel holders in this size are generally rated around 6.3-10 A at 250 V, with limited breaking capacity. It is the right choice for control circuits, small PSUs and anything under about 5 A continuous.&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;6.3x32&lt;/strong&gt; is the industrial size. 16 A at 250 V is routine, higher breaking capacity, and the ceramic body survives a real fault without shattering. This is what belongs downstream of a 16 A panel switch.&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;The mistake I see most: a 16(4)A rocker switch with a 5x20 holder on the same panel, because the holder was cheaper. The switch is fine; the holder's contacts and the fuse's interrupting rating are the weak link. Match the holder to the &lt;strong&gt;load&lt;/strong&gt;, not to the switch's outside number.&lt;/p&gt;

&lt;p&gt;Also check the holder's own contact resistance: a tired panel fuse holder adds 20-50 mΩ in series with everything else, which shows up as a hot spot long before the fuse blows.&lt;/p&gt;

&lt;h2&gt;
  
  
  Inlets: C14 vs C20 (and why C16 is not the answer)
&lt;/h2&gt;

&lt;p&gt;IEC 60320 inlets are keyed by current, and the keyway is physical, so you cannot mis-mate them:&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Inlet&lt;/th&gt;
&lt;th&gt;Rated&lt;/th&gt;
&lt;th&gt;Mates with&lt;/th&gt;
&lt;th&gt;Notes&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;C14&lt;/td&gt;
&lt;td&gt;10 A / 250 V&lt;/td&gt;
&lt;td&gt;C13 cord&lt;/td&gt;
&lt;td&gt;The default for most equipment&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;C16&lt;/td&gt;
&lt;td&gt;10 A / 250 V, 120 C&lt;/td&gt;
&lt;td&gt;C15 cord&lt;/td&gt;
&lt;td&gt;Hot-condition variant, &lt;strong&gt;not&lt;/strong&gt; a 16 A part&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;C20&lt;/td&gt;
&lt;td&gt;16 A / 250 V&lt;/td&gt;
&lt;td&gt;C19 cord&lt;/td&gt;
&lt;td&gt;Wider blades, larger body&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;So a 16 A product cannot use a C14 inlet. It needs C20, or it needs to stay under 10 A. The C16 trap catches people who read "16" as amps: it is a temperature rating, for kettles and heaters, and it is still a 10 A inlet.&lt;/p&gt;

&lt;h2&gt;
  
  
  The 3-pin rocker switch: which pin is ground?
&lt;/h2&gt;

&lt;p&gt;None of them. A rocker switch has no protective earth terminal, and no switch pin should ever be tied to chassis earth as a current path.&lt;/p&gt;

&lt;p&gt;The three pins on an illuminated rocker are:&lt;/p&gt;

&lt;ul&gt;
&lt;li&gt;
&lt;strong&gt;Two switch terminals&lt;/strong&gt; (line in, load out).&lt;/li&gt;
&lt;li&gt;
&lt;strong&gt;One lamp return&lt;/strong&gt; for the internal neon or LED, which is why a 3-pin illuminated switch needs a neutral even though it sits in the live leg.&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;You can identify them in ten seconds with a meter on continuity, switch OFF: the pair that beeps is the lamp circuit, because the lamp and its series resistor sit permanently across those two pins. The remaining pair is the switch contact, which only beeps with the switch ON.&lt;/p&gt;

&lt;p&gt;If a wiring diagram shows a pin going to earth, that pin is on the inlet or the terminal block, not the switch.&lt;/p&gt;




&lt;p&gt;I work with a manufacturer of these parts, so treat this as field notes. The same numbers, with the tables side by side, are collected on &lt;a href="https://www.cweup.com/answers/" rel="noopener noreferrer"&gt;this answer page&lt;/a&gt;, including the &lt;a href="https://www.cweup.com/rocker-switch-3-pin-wiring-which-is-ground/" rel="noopener noreferrer"&gt;3-pin rocker pinout test&lt;/a&gt;.&lt;/p&gt;

&lt;h2&gt;
  
  
  The full tables for each item
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;&lt;a href="https://www.cweup.com/rocker-switch-panel-cutout-size/" rel="noopener noreferrer"&gt;Rocker switch panel cutout sizes: 30x22, 19x13 and the round sizes&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://www.cweup.com/panel-fuse-holder-5x20-vs-6x32/" rel="noopener noreferrer"&gt;Panel fuse holder: 5x20 vs 6.3x32 mm&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://www.cweup.com/c14-vs-c20-inlet-difference/" rel="noopener noreferrer"&gt;C14 vs C20 inlet: current class and pin temperature&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://www.cweup.com/rocker-switch-3-pin-wiring-which-is-ground/" rel="noopener noreferrer"&gt;3 pin rocker switch wiring: which pin is ground&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;

</description>
      <category>diy</category>
      <category>iot</category>
    </item>
    <item>
      <title>Reading a rocker switch nameplate: 16(4)A, T85/T125, 30 mΩ and IPX4 vs IPX6</title>
      <dc:creator>Yves Wu</dc:creator>
      <pubDate>Fri, 27 Nov 2026 16:33:57 +0000</pubDate>
      <link>https://dev.to/weup_switches/reading-a-rocker-switch-nameplate-164a-t85t125-30-mo-and-ipx4-vs-ipx6-83p</link>
      <guid>https://dev.to/weup_switches/reading-a-rocker-switch-nameplate-164a-t85t125-30-mo-and-ipx4-vs-ipx6-83p</guid>
      <description>&lt;p&gt;Most spec arguments I get dragged into are not about the switch. They are about the four numbers stamped on its side. A label like &lt;code&gt;KCD4 16(4)A 250V~ T85&lt;/code&gt; contains four independent limits, and each one gets misread in a predictable direction. Here is how each is actually defined, and what happens when you assume the wrong thing.&lt;/p&gt;

&lt;h2&gt;
  
  
  1. &lt;code&gt;16(4)A&lt;/code&gt; is two ratings, not one
&lt;/h2&gt;

&lt;p&gt;The outside number is the rated current for the standard resistive test circuit in IEC 61058-1. The number in brackets is the rated current for the inductive test circuit, run at a defined lagging power factor.&lt;/p&gt;

&lt;p&gt;So a 16(4)A part is a 16 A resistive switch and a 4 A inductive switch. It is not "16 A, with 4 A of inrush headroom". If you put a 0.75 kW motor, a transformer-fed load or an LED driver on it and pull 10 A, you are 2.5x over the inductive rating. The contact set erodes, the arc does not self-extinguish at zero crossing, and somewhere between a few hundred and a few thousand operations the contacts weld closed.&lt;/p&gt;

&lt;p&gt;Neither number is an inrush limit. Capacitive and electronic loads pull 20x to 100x rated current for the first few milliseconds after switch-on. A KCD4 that welds on a 60 W LED driver is not a defective switch: it is a switch being asked for a closing current nobody rated it for. Fix it upstream with an NTC, a pre-charge resistor or a relay driven by the rocker, not with a bigger switch.&lt;/p&gt;

&lt;h2&gt;
  
  
  2. &lt;code&gt;T85&lt;/code&gt; / &lt;code&gt;T105&lt;/code&gt; / &lt;code&gt;T125&lt;/code&gt; is ambient, not surface temperature
&lt;/h2&gt;

&lt;p&gt;The T number is the maximum ambient air temperature around the switch body at which the part still meets its rated current and its temperature-rise limit.&lt;/p&gt;

&lt;p&gt;Two consequences that matter in real panels:&lt;/p&gt;

&lt;ul&gt;
&lt;li&gt;A T85 switch in a 95 C enclosure is out of spec even though nothing feels hot. Spring temper and contact plating degrade faster than the datasheet's electrical life table assumes, and contact resistance starts to drift upward well before anything visibly fails.&lt;/li&gt;
&lt;li&gt;Electrical life roughly halves for every 10 C of sustained over-temperature. A "30,000 operations" figure measured at 25 C is not the number you will get at 100 C.&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;Measure it properly: thermocouple 10 mm from the body, after one hour at rated load, with the enclosure closed. Enclosure air temperature at the top of the box is usually 10-20 C above what the switch actually sees, and measuring that instead is how people end up buying T125 parts they did not need.&lt;/p&gt;

&lt;h2&gt;
  
  
  3. &lt;code&gt;30 mΩ&lt;/code&gt; contact resistance is a screen, not a thermal number
&lt;/h2&gt;

&lt;p&gt;30 mΩ is a dry-circuit figure: it is measured with a low test current, four-wire, so that probe and lead resistance are excluded.&lt;/p&gt;

&lt;p&gt;Do the arithmetic before treating it as a power loss. 16 A through 30 mΩ is 7.7 W in a component the size of a thumbnail. No 30x22 mm rocker survives that. The real thermal acceptance criterion is temperature rise at rated current, not contact resistance, and this is why a switch can pass 30 mΩ on the line and still overheat in service.&lt;/p&gt;

&lt;p&gt;Where the number does earn its keep is as a wear screen:&lt;/p&gt;

&lt;div class="table-wrapper-paragraph"&gt;&lt;table&gt;
&lt;thead&gt;
&lt;tr&gt;
&lt;th&gt;Stage&lt;/th&gt;
&lt;th&gt;Expected&lt;/th&gt;
&lt;/tr&gt;
&lt;/thead&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;New part&lt;/td&gt;
&lt;td&gt;10-30 mΩ&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;After 10,000 cycles at rated load&lt;/td&gt;
&lt;td&gt;30-50 mΩ&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;50-100 mΩ&lt;/td&gt;
&lt;td&gt;worn, plan replacement&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&amp;gt;100 mΩ&lt;/td&gt;
&lt;td&gt;hot joint, do not ship&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;&lt;/div&gt;

&lt;p&gt;Use a four-wire milliohm meter. A two-wire multimeter adds 0.2-0.5 Ω of lead and probe resistance and will tell you a good switch is scrap.&lt;/p&gt;

&lt;h2&gt;
  
  
  4. &lt;code&gt;IPX4&lt;/code&gt; vs &lt;code&gt;IPX6&lt;/code&gt;: the X is not a zero
&lt;/h2&gt;

&lt;p&gt;IPX4 is splash from any direction for 10 minutes with an oscillating nozzle. IPX6 is a 12.5 mm nozzle at 100 L/min from 3 m for at least 3 minutes.&lt;/p&gt;

&lt;p&gt;IPX6 is not a stronger version of IPX4 in the way people assume: it is a jet test, and a switch can pass 6 while failing 4 if its gasket is designed for pressure but not for pooling. More importantly:&lt;/p&gt;

&lt;ul&gt;
&lt;li&gt;
&lt;strong&gt;X means dust ingress was not tested.&lt;/strong&gt; IP54 to IP65 is not an upgrade you can assume; it is a different test series.&lt;/li&gt;
&lt;li&gt;The rating covers the &lt;strong&gt;front face, installed in a panel&lt;/strong&gt;. The rear terminals are not protected by it. Cable side water ingress is a separate problem and usually the one that actually kills the part.&lt;/li&gt;
&lt;li&gt;The seal is done by the actuator boot and the panel gasket, both of which depend on panel thickness and mounting torque. The same switch is IPX4 in a 2 mm panel and not IPX4 in a 5 mm panel with a deformed gasket.&lt;/li&gt;
&lt;/ul&gt;

&lt;p&gt;For rain exposure, IPX4 with a correctly torqued gasket is normally enough. For washdown or hose-directed cleaning you need IPX6 plus a drain path, because a sealed switch in a sealed pocket just fills with condensate.&lt;/p&gt;

&lt;h2&gt;
  
  
  5. The five questions to ask before you spec
&lt;/h2&gt;

&lt;ol&gt;
&lt;li&gt;What is the load type: resistive, motor, transformer or capacitive input? Pick the rating that matches.&lt;/li&gt;
&lt;li&gt;What is the measured ambient at the switch body with the enclosure closed?&lt;/li&gt;
&lt;li&gt;What inrush will the load present for the first 10 ms?&lt;/li&gt;
&lt;li&gt;Is water hitting the front face only, or the terminals too?&lt;/li&gt;
&lt;li&gt;What electrical life do you need at that load and that temperature, not at 25 C?&lt;/li&gt;
&lt;/ol&gt;

&lt;p&gt;Answer those five and the nameplate stops being ambiguous.&lt;/p&gt;




&lt;p&gt;I work with a manufacturer of panel switches, fuse holders and IEC 60320 inlets, so treat the numbers above as field notes rather than an independent test report. If you want the same breakdown for more specs (cutout sizes, fuse holder sizes, C14 vs C20, 3-pin pinouts), they are collected on &lt;a href="https://www.cweup.com/answers/" rel="noopener noreferrer"&gt;this switch and connector answers page&lt;/a&gt;.&lt;/p&gt;

&lt;h2&gt;
  
  
  Where each number is covered in full
&lt;/h2&gt;

&lt;ul&gt;
&lt;li&gt;&lt;a href="https://www.cweup.com/rocker-switch-16-4a-derating-motor-load/" rel="noopener noreferrer"&gt;16(4)A on a rocker switch, and what the bracketed figure does to motor loads&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://www.cweup.com/switch-temperature-rating-t85-t105-t125/" rel="noopener noreferrer"&gt;Switch temperature rating: T85 vs T105 vs T125&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://www.cweup.com/rocker-switch-contact-resistance-30-milliohm/" rel="noopener noreferrer"&gt;Rocker switch contact resistance and the 30 mOhm limit&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;a href="https://www.cweup.com/ipx4-vs-ipx6-panel-switch/" rel="noopener noreferrer"&gt;IPX4 vs IPX6 on a panel-mount rocker switch&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;

</description>