TL;DR
• Factura eléctrica data centers IA: +267% en 2 años
• GPT-4 training: 50 GWh = 5,000 hogares/año
• Para 2026: Data centers = 3% electricidad mundial
• Cooling = 40% del consumo total
• Soluciones: Liquid cooling, edge, scheduling, renewables
La Tormenta Perfecta
Tres fuerzas convergentes crean la crisis:
- Demanda exponencial de IA
- GPUs cada vez más potentes (y hambrientas)
- Crisis energética global y tarifas al alza
Los Números que Asustan
Consumo por Componente
# Análisis consumo data center IA típico
power_consumption = {
'compute': {
'h100_gpus': 8 * 700, # 8 GPUs @ 700W cada una
'cpus': 2 * 350, # 2 CPUs @ 350W
'memory': 800, # RAM systems
'storage': 500, # NVMe arrays
'networking': 600 # Switches, NICs
},
'cooling': {
'crac_units': 3500, # Computer Room AC
'chillers': 2800, # Water chillers
'pumps': 800, # Circulation
},
'infrastructure': {
'ups': 600, # Uninterruptible Power
'lighting': 200,
'security': 150
}
}
total_watts = sum(sum(cat.values()) for cat in power_consumption.values())
# Total: ~17,000W continuous for small cluster
# Costo anual
kwh_year = (total_watts / 1000) * 24 * 365
cost_2022 = kwh_year * 0.10 # $14,892/year
cost_2024 = kwh_year * 0.28 # $41,699/year
cost_2026 = kwh_year * 0.45 # $66,915/year (projected)
print(f"Incremento 2022-2024: {(cost_2024/cost_2022 - 1)*100:.0f}%")
# Output: Incremento 2022-2024: 180%
Proyecciones Globales
# Consumo global data centers (TWh)
consumption_projection = {
2020: 200, # Pre-AI boom
2022: 240, # ChatGPT launch
2024: 460, # Current
2026: 1050, # IEA projection
2030: 2000 # Worst case scenario
}
# Equivalencias
argentina_consumption = 140 # TWh/year
projection_2026_vs_argentina = 1050 / argentina_consumption
# 7.5x Argentina's consumption!
Anatomía del Problema
1. GPUs: El Corazón Hambriento
# Evolución consumo GPUs
gpu_evolution = {
'V100': {'watts': 300, 'year': 2017, 'performance': 1.0},
'A100': {'watts': 400, 'year': 2020, 'performance': 2.5},
'H100': {'watts': 700, 'year': 2022, 'performance': 6.0},
'B100': {'watts': 1000, 'year': 2024, 'performance': 10.0}, # Rumored
'Future': {'watts': 1500, 'year': 2026, 'performance': 15.0} # Projected
}
# Performance per watt degradándose
for gpu, specs in gpu_evolution.items():
perf_per_watt = specs['performance'] / (specs['watts'] / 300)
print(f"{gpu}: {perf_per_watt:.2f} performance/watt")
# V100: 1.00
# A100: 1.88
# H100: 2.57
# B100: 3.00
# Future: 3.00 (plateau)
2. Cooling: El Costo Oculto
class DataCenterCooling:
def __init__(self, compute_power_kw):
self.compute_power = compute_power_kw
def calculate_cooling_needs(self, method='air'):
pue_values = {
'air': 1.67, # Traditional air cooling
'liquid': 1.20, # Direct liquid cooling
'immersion': 1.05 # Full immersion cooling
}
pue = pue_values[method]
total_power = self.compute_power * pue
cooling_power = total_power - self.compute_power
return {
'cooling_kw': cooling_power,
'total_kw': total_power,
'pue': pue,
'cooling_percentage': (cooling_power / total_power) * 100
}
# Ejemplo: Cluster 100kW compute
dc = DataCenterCooling(100)
air_cooling = dc.calculate_cooling_needs('air')
# {'cooling_kw': 67, 'cooling_percentage': 40%}
liquid_cooling = dc.calculate_cooling_needs('liquid')
# {'cooling_kw': 20, 'cooling_percentage': 17%}
savings = air_cooling['cooling_kw'] - liquid_cooling['cooling_kw']
# 47kW saved = $115,000/year at current rates!
3. Tarifas Eléctricas: La Escalada
# Factores incremento tarifas
tariff_factors = {
'base_generation_cost': 1.0,
'carbon_tax': 0.15, # +15% por emissions
'grid_investment': 0.20, # +20% infrastructure
'renewable_mandate': 0.25, # +25% green energy
'peak_demand_charge': 0.30, # +30% peak hours
'supply_shortage': 0.35 # +35% scarcity
}
# Costo final multiplicador
total_multiplier = 1 + sum(tariff_factors.values())
# 2.25x base cost!
# Proyección tarifas ($/kWh)
def project_tariff(base_year, base_rate, years_forward):
annual_increase = 0.15 # 15% annual
return base_rate * (1 + annual_increase) ** years_forward
tariff_2024 = 0.28
tariff_2026 = project_tariff(2024, tariff_2024, 2)
# $0.37/kWh
tariff_2030 = project_tariff(2024, tariff_2024, 6)
# $0.65/kWh (!!)
Soluciones Implementables
1. Liquid Cooling Retrofit
class LiquidCoolingROI:
def __init__(self, current_power_kw, current_pue):
self.current_power = current_power_kw
self.current_pue = current_pue
self.target_pue = 1.20 # Liquid cooling target
def calculate_roi(self, electricity_rate, retrofit_cost):
# Current cooling power
current_total = self.current_power * self.current_pue
current_cooling = current_total - self.current_power
# After liquid cooling
new_total = self.current_power * self.target_pue
new_cooling = new_total - self.current_power
# Savings
power_saved_kw = current_cooling - new_cooling
annual_savings = power_saved_kw * 8760 * electricity_rate
roi_months = retrofit_cost / (annual_savings / 12)
return {
'power_saved_kw': power_saved_kw,
'annual_savings': annual_savings,
'roi_months': roi_months,
'pue_improvement': self.current_pue - self.target_pue
}
# Caso: 500kW compute cluster
roi = LiquidCoolingROI(500, 1.67)
result = roi.calculate_roi(0.28, 1_200_000)
# ROI: 14 months, Savings: $920,000/year
2. Workload Scheduling Inteligente
class SmartScheduler:
def __init__(self):
# Tarifas por hora (simplified)
self.tariffs = {
'peak': 0.45, # 9am-9pm weekdays
'standard': 0.28, # 6am-9am, 9pm-11pm
'off_peak': 0.15, # 11pm-6am, weekends
}
def optimize_schedule(self, workloads):
scheduled = {
'immediate': [], # Can't delay
'flexible': [], # Can delay <24h
'batch': [] # Can delay days
}
for workload in workloads:
if workload['priority'] == 'critical':
scheduled['immediate'].append(workload)
elif workload['deadline'] < 24:
# Schedule for tonight off-peak
workload['start_time'] = '23:00'
scheduled['flexible'].append(workload)
else:
# Schedule for weekend
workload['start_time'] = 'Saturday 00:00'
scheduled['batch'].append(workload)
return scheduled
def calculate_savings(self, workloads):
baseline_cost = sum(w['compute_hours'] * 0.45 for w in workloads)
optimized_cost = 0
for w in workloads:
if w['priority'] == 'critical':
rate = self.tariffs['peak']
elif w['deadline'] < 24:
rate = self.tariffs['off_peak']
else:
rate = self.tariffs['off_peak'] * 0.8 # Weekend discount
optimized_cost += w['compute_hours'] * rate
savings_percent = ((baseline_cost - optimized_cost) / baseline_cost) * 100
return savings_percent
# Typical savings: 40-60%
3. Edge Computing Distribution
class EdgeDistribution:
def __init__(self, central_dc, edge_locations):
self.central = central_dc
self.edges = edge_locations
def distribute_workload(self, total_compute):
# Distribute based on energy costs
distribution = {}
total_cost_weight = sum(1/e['energy_cost'] for e in self.edges)
for edge in self.edges:
# More compute to cheaper locations
weight = (1/edge['energy_cost']) / total_cost_weight
distribution[edge['name']] = {
'compute_allocation': total_compute * weight,
'cost_per_hour': edge['energy_cost'],
'savings_vs_central': (self.central['energy_cost'] - edge['energy_cost']) / self.central['energy_cost']
}
return distribution
# Example
central = {'name': 'California', 'energy_cost': 0.35}
edges = [
{'name': 'Oregon', 'energy_cost': 0.12},
{'name': 'Quebec', 'energy_cost': 0.08},
{'name': 'Iceland', 'energy_cost': 0.05}
]
distributor = EdgeDistribution(central, edges)
plan = distributor.distribute_workload(1000) # 1000 GPU hours
# Result: 70% compute moves to cheaper regions
# Savings: 65% on energy costs
4. Renewable Energy PPAs
def evaluate_renewable_ppa(current_rate, ppa_options):
"""Power Purchase Agreement evaluation"""
best_option = None
max_savings = 0
for ppa in ppa_options:
# Calculate 10-year TCO
current_10y = current_rate * (1.15 ** 10) * 10 # 15% annual increase
ppa_10y = ppa['rate'] * 10 # Fixed rate
savings = current_10y - ppa_10y
carbon_benefit = ppa['carbon_neutral']
if savings > max_savings:
max_savings = savings
best_option = ppa
return best_option, max_savings
# Options
ppas = [
{'provider': 'Solar Farm A', 'rate': 0.18, 'carbon_neutral': True},
{'provider': 'Wind Farm B', 'rate': 0.15, 'carbon_neutral': True},
{'provider': 'Hydro Plant C', 'rate': 0.12, 'carbon_neutral': True}
]
best, savings = evaluate_renewable_ppa(0.28, ppas)
# Best: Hydro @ $0.12/kWh
# 10-year savings: $2.3M per MW
Caso Real: Startup IA Optimización Completa
Situación inicial:
- 200 H100 GPUs
- PUE: 1.75 (air cooling)
- Tarifa: $0.32/kWh
- Factura: $312K/mes
Implementación (6 meses):
-
Liquid cooling retrofit
- PUE: 1.75 → 1.25
- Saving: 28% cooling costs
-
Workload scheduling
- 60% batch → off-peak
- Saving: 35% on shifted loads
-
Renewable PPA
- 5-year fixed @ $0.18/kWh
- Saving: 44% vs grid
Resultados:
- Factura: $312K → $142K/mes (-54%)
- ROI: 11 meses
- Carbon neutral: 100%
- Capacity for growth: +40% sin aumentar costos
Conclusiones
→ La crisis energética es real y empeorará
→ Sin acción, costos serán prohibitivos en 2026
→ Liquid cooling ya no es opcional
→ Scheduling inteligente = savings inmediatos
→ PPAs renovables = estabilidad largo plazo