DEV Community

Kevin
Kevin

Posted on

Inside the OCT Machine: A Developer's Look at Retinal Imaging Tech

Optical Coherence Tomography (OCT) has revolutionized ophthalmology. In seconds, it captures micrometer-resolution, cross-sectional images of the retina—enabling early detection of glaucoma, macular degeneration, and diabetic retinopathy. But as a developer, I’ve always wondered: what’s happening under the hood? How does light become data? And more importantly—can we, as software engineers, interact with that pipeline?

Let’s peel back the layers—not of the retina, but of the OCT machine itself.

From Light to Data: The Core Principle

At its heart, [OCT] is a form of optical interferometry. It splits a near-infrared light beam: one part goes into the patient’s eye, the other into a reference mirror. When the reflected beams recombine, they create an interference pattern. The machine measures this pattern across thousands of scan points to reconstruct a 3D retinal map.

Unlike MRI or CT, OCT uses no radiation—just light and math. And that math? It’s heavy on Fourier transforms, signal filtering, and image reconstruction algorithms. Much of this is now implemented on FPGA or GPU-accelerated embedded systems inside the device.

The Developer’s Entry Point: Data Output Interfaces

While real-time image generation happens in proprietary firmware, many modern OCT devices expose standardized data outputs:

  • DICOM (Digital Imaging and Communications in Medicine): The universal format in medical imaging. OCT scans are often exported as DICOM files containing both pixel data and metadata (e.g., scan depth, patient ID, layer segmentation).
  • HL7/FHIR over Ethernet: For integration with hospital PACS or EHR systems.
  • USB/Network Streaming APIs: Some research-grade models offer SDKs that allow raw A-scan or B-scan data streaming.

This is where developers can add value—not by building the OCT, but by processing, visualizing, or analyzing its output.

Open Tools for OCT Data

You don’t need a $100k machine(OCT-1000 Machine) to start experimenting. Several open-source projects make retinal imaging accessible:

  • OCTOR (community project): A Python toolkit to read OCT DICOM files, extract retinal layer thickness maps, and export to NumPy arrays.
  • 3D Slicer: An NIH-backed open platform for medical image visualization. It supports OCT plugins and can render volumetric scans in-browser via WebAssembly.
  • MONAI: While focused on AI, this PyTorch-based framework includes pre-trained models for segmenting retinal layers—ideal for prototyping diagnostic assistants.

Example: loading an OCT scan in Python:

import pydicom
import matplotlib.pyplot as plt

ds = pydicom.dcmread("oct_scan.dcm")
plt.imshow(ds.pixel_array[0], cmap='gray')  # Show first B-scan slice
plt.title("Retinal Cross-Section (OCT)")
plt.show()
Enter fullscreen mode Exit fullscreen mode

Simple? Yes. But this is the foundation for AI-driven screening tools or tele-ophthalmology dashboards.

Why Interoperability Still Lags

Despite DICOM, many OCT vendors lock advanced features (e.g., raw interferogram data or real-time streaming) behind closed APIs. Worse, some embed patient data in non-standard DICOM fields, breaking downstream pipelines.

Top comments (0)