Most boardroom and lobby retrofits start with the same sentence: "there is a screen on that wall, and nothing behind it." That single constraint decides almost everything else about the job — the cabinet type, the mounting profile, the steel, and how the thing gets serviced for the next eight years.
I have spent enough site visits watching rear-service walls get value-engineered into front-service ones to have a bias, so let me put the numbers on the table instead of the opinion.
The 800 mm you are actually paying for
A rear-service wall needs a walkable aisle. Call it 800 mm minimum for a person plus a toolbox, and in practice 900 mm if anyone has to kneel. Multiply that by the wall width and you are not giving up a corridor, you are giving up rentable floor area in the most expensive square metres of the building. In a lobby that aisle also has to be lit, ventilated, and kept clear of the fire riser that was already there.
Then the aisle needs a structure. A walkway behind a wall means a deeper steel frame, a floor that can take a person's load, and often a penetration in a finished ceiling. Every one of those items lands on the main contractor, and every one of them shows up late in the programme because nobody drew it in the concept stage.
What a flush wall changes
A front-service cabinet mounts on a 40 to 60 mm profile fixed straight to the substrate. The screen face finishes flat to the plaster, or with a 10 mm shadow gap if the designer wants one. The wall behind can be block, concrete, or steel stud — what matters is that it is straight, because at 2.5 mm pitch any bow in the substrate telegraphs itself as a shadow line across the modules.
Service then happens from the room. A module comes off with a suction tool, the ribbon and power leads are already on the front face, and a swap is a five to ten minute job with the room in use. No barrier, no notice to building management, no lifting equipment.
What front service does not fix
This is the part the brochures skip. Front service moves the module to the front; it does not move the power supplies, the receiving card, or the sending hardware. On most cabinets those live behind the modules, which means a failed PSU is still a front-access job — fine — but it also means the cavity behind the screen must be deep enough for them and open enough to breathe. Budget 60 to 100 mm of clear depth and treat ventilation as a design item, not an afterthought.
Heat is the second thing. Warm air rises, so the top row of a flush wall runs hotter than the bottom, and a wall tight against a warm plant room on the other side runs hotter still. If the substrate is external wall, insulate before you mount, not after the first dead pixel column appears in July.
Third: flatness. Front-service modules are held by magnets or quarter-turn screws and they are only as flat as what they are fixed to. Skim coat, cure, then measure with a 2 m straight edge. I have seen a perfectly good cabinet set look like a bad batch because the wall had a 6 mm wave in it.
The clearance nobody draws
Front service needs room in front. A credenza pushed against the screen turns a five minute swap into a furniture-moving exercise, and a screen starting 400 mm above the floor means somebody is working on their knees. Put 1.2 m of clear floor in the furniture layout and write "no fixed joinery within 1.2 m" on the drawing. It costs nothing at design stage and is impossible to retrofit.
What I would ask before signing
Three questions settle most of it. What is behind the wall — concrete, block, or stud, and is there a service void? How deep is the cavity, and where does the heat go? And who holds spare modules and a suction tool on site, because the mean time to repair is decided by whether a spare is in the building, not by the cabinet design.
Get those three answers and the choice stops being a preference. It becomes arithmetic: an aisle you pay rent on for a decade, or a wall you can service from a chair in ten minutes.
Front-service flush wall, or rear-service with an 800 mm aisle — which would you sign off for a boardroom retrofit?