A material selection meeting usually ends with a board of samples, a colour name, and a note to proceed. The risk appears later, when cartons arrive and the approved surface no longer matches the room. The problem is not necessarily poor material. It is that three different approvals have been treated as one: design intent, product identity, and production batch.
Architectural ceramics deserve a cleaner handover. The sample board can confirm direction. The exact product record confirms what was selected. The batch record confirms what may be delivered. CERMIACTILE’s catalogue helps with the middle step, but it does not replace a physical approval or a supplier’s shade information.
Name the product before naming the colour
“Grey,” “white,” and “blue” are useful design words and weak ordering references. The CERMIACTILE master reference contains 4,467 unique CP archive codes across 11 categories. A selection should carry the CP code and, where available, the supplier model. It should also carry the source page, finish, dimensions, and any unresolved verification status.
Consider the large-slab entries YY1224R306 and YY1224R404. Both are recorded as 1200 × 2400 mm matte slabs, but they are separate products with separate source pages. A schedule that says only “matte grey large slab” removes the information needed to compare delivery against approval.
The same issue appears in mosaic. SNZ090AOM-447A-15 is recorded as a 37 × 300 mm chip on a 302 × 314 × 15 mm sheet. The sheet has a visible mix that should be reviewed as a module, not as a single chip colour. A colour swatch cannot describe every placement, orientation, or edge cut.
Give the sample a limited role
A sample board is most useful for narrowing appearance, texture, and relationship to adjacent materials. It should not silently become proof of slip resistance, chemical resistance, water absorption, freeze-thaw suitability, or batch consistency. Those questions require product-specific documents and, where applicable, project-specific review.
Mark each approved sample with the exact CP code, supplier model, sample date, and approving party. State whether the approval covers colour direction only or the complete listed product attributes. This prevents a later reviewer from treating a visual approval as a technical release.
For patterned materials, keep a photograph of the approved arrangement with the physical sample. Record which face was up, whether the pattern was rotated, and how it met the adjacent finish. A sample detached from its intended orientation can create a dispute that no catalogue image can settle.
Ask for shade and batch information in a usable form
A colour name is not a batch guarantee. Before ordering, ask the supplier how shade or batch variation is identified for the exact product. The answer may appear on cartons, certificates, labels, or separate delivery documents. Record the format and the party responsible for checking it.
At delivery, compare the identifiers with the approval record before opening or mixing every carton. Keep cartons grouped long enough to inspect a representative selection. If an identifier is missing or inconsistent, stop and request clarification rather than distributing the material into different rooms.
Spare material needs the same identity trail. Agree the quantity from the project’s own risk assessment and supplier guidance. The master reference does not provide a universal waste or attic-stock percentage. Store approved spare pieces with their labels, protected from damage, and record where they are kept. Unlabelled offcuts are difficult to match later.
Wet locations need their own approval
A sample that looks acceptable when dry tells little about a barefoot route around a pool. Separate the underwater surface, pool edge, step, corner, and wet deck in the selection schedule. Each location can require a different piece, joint treatment, or technical document.
Request the exact product’s slip-related evidence and identify the test method and conditions. Do not transfer a result from one finish, one thickness, or one model to another. Chemical exposure and water absorption also need product-specific review for the intended pool environment. A catalogue category or a water-inspired image is not evidence of suitability.
Keep project images in their original context
CERMIACTILE is a directory brand. Its reference material includes supplier brochures, including documents from SEED, 艺岩玖鼎, FMAX, 9Fang, 建华, 狮王, and 白兔. Application photographs can show a material direction without proving who contracted, manufactured, or installed the project.
That distinction belongs in the approval file. If a supplier case is used to explain a finish, name the supplier source and keep the example separate from CERMIACTILE’s own role. The master reference specifically treats white-rabbit exterior-wall examples as supplier brochure material, not as CERMIACTILE project history.
A one-page approval record
The record does not need to be elaborate. It needs to be unambiguous.
| Field | What to record |
|---|---|
| Product identity | CP code, supplier model, source page |
| Appearance | Finish, colour name, pattern orientation |
| Sample | Physical reference, photograph, approval date |
| Batch | Supplier identification method and delivery identifiers |
| Quantity | Net area, sales unit, cartons, agreed spare quantity |
| Use location | Wall, floor, facade, pool zone, roof zone |
| Evidence | Technical documents requested or received |
| Responsibility | Approver, supplier contact, delivery checker |
This page travels with the order and returns at delivery. If the product changes, the approval changes with it. If the batch identifier cannot be matched, the material remains on hold.
Keep the page under version control in the project file. A revised sample should not erase the earlier approval. Record which version was sent with the purchase order and which version the delivery checker used. Where several rooms share a product, note any zone-specific exception so that one accepted variation is not applied everywhere by default.
The record should also state the agreed method for resolving a visible difference. That may involve comparing cartons side by side, reviewing a larger physical sample, or asking the supplier to identify the relevant batch information. It should not begin with an informal promise that all ceramic colours naturally match.
The CERMIACTILE catalogue is a starting point for identifying candidates. The technical selection area can support the request for exact documents. The approval itself remains a project record linking the selected product, the accepted sample, and the material that arrives.
Top comments (0)