As a professional provider of IoT data acquisition solutions and an expert in industrial IoT data acquisition, the editor of Shanghai Data Acquisition IOT Technology Co., Ltd, (daq-iot) hereby presents the following introduction, and sincerely welcomes discussions and exchanges.
Supported Communication Interfaces: CAN, RS485, Mbus, 4–20mA, Profibus, CC-Link, HART, digital I/O, etc.
Industrial Protocols: Modbus RTU/TCP, HJ212, IEC104, DLT645, DLMS, IEC61850, MQTT, etc.
Mail:export@daq-iot.com
asIoTData Acquisitionsolution Professional provider,Industrial Data AcquisitionExpert (professional), data acquisition IoT editor daq iot would like to introduce the following content here, and sincerely welcome everyone to discuss and exchange ideas.
As a professional internet of things data acquisition solutions provider, industrial data acquisition experts (professional households), digital internet of things editor daq - iot here to do the following introduction, and sincerely welcome everyone to discuss and exchange.

Equipment Name Equipment Brand Quantity Control System Manufacturer Requirement Parameters (Collection Content) Unable to collect content Whether the content meets the docking conditions Network Deployment Communication Interface (PLC485Etc.)
Marking machine equipment Hangzhou Yongchuang 2 Siemens 1 # marking speed; 2 # Marking speed; Steam pressure; 1 # Shrinkage furnace temperature; 2 # Shrinkage furnace temperature; The total number of sets of labels has been completed Siemens D445(S7)
Set label inspection machine Hangzhou Yongchuang 2 Siemens no label; High and low standards; Wrinkle label; Heterochromatic label; The bottle sample test has been completed for Siemens D445 (S7)
Luggage machine Hangzhou Yongchuang 1 Siemens compressed air pressure; Hot melt glue machine temperature (glue box); Hot melt glue machine temperature (rubber hose); Hot melt adhesive machine; Temperature (adhesive head); The number of packaging boxes is in progress for Siemens D445 (S7)
Hot melt adhesive dosage; Tape usage
Stacking machine Hangzhou Yongchuang Siemens box serial number; Number of boxes; The plate number (stack code) has been completed for Siemens D445 (S7)
UHT Tetra Pak Siemens air pressure inlet; Balance tank liquid level; Maintain the inlet temperature of the tube; Maintain the outlet temperature of the pipe; Reflux temperature; Hot water circulation temperature; Steam generator temperature; Hot water flow rate; Sterilization flow rate; Sterilization temperature; Sterilization time; Discharge temperature; Product back pressure; Is the temperature of the steam generator and the pressure difference between the material tube and the medium tube (unable to provide the point location) in progress? Siemens S7
Aseptic tank Tetra Pak Siemens inlet steam inlet pressure; Air pressure input; Aseptic gas outlet pressure; Aseptic tank liquid level T; End vapor barrier temperature; Temperature at the outlet of the mixer condensate barrier; Aseptic irrigation with positive pressure; The sterile air filter is replaced every 50 times with SIP, and the inlet pressure of the air pressure and the outlet temperature of the condenser water barrier of the agitator are not available (point cannot be provided). Siemens S7 is currently in progress
Job deployment: Shanghai Shugao 1 Siemens Baili Du; Brix; PH; Total acid is (the supplier has summarized the points into one PLC for docking) has been completed by Siemens
The start time of Siemens sugar injection at the sugar dissolving post in Shanghai; End time of sugar infusion; Dissolving water temperature; Dissolved water volume; Mixing start time; Mixing end time; Starting time for sugar delivery; End time of sugar delivery; Filter pressure difference; Cylinder flushing water volume, steam inlet pressure, Siemens PLC
Dissolved sugar pasteurization machine Shanghai Shugao Siemens syrup sterilization flow rate; Sterilization time of syrup; Sterilization temperature of syrup; Balance tank liquid level; Syrup outlet pressure; Sugar syrup outlet temperature; Ice water pressure; Tower water pressure; Steam inlet pressure Siemens PLC
Dissolve the water quantity of Shanghai and Siemens at the post; Dissolving temperature; Start time of feeding; End time of feeding; Discharge time; Filter pressure difference; Top water filter pressure difference Siemens PLC
The start time for the deployment of Shanghai Shugao to Siemens; Fixed capacity; Temperature; Starting time of material supply; End time of material supply; Filter pressure difference; Start time of water washing; End time of water washing; Washing flow rate; Washing temperature; Start time of alkaline washing; End time of alkaline washing; Alkali washing concentration; Alkali washing temperature; Alkali washing flow rate; Start time of acid washing; End time of acid washing; Acid washing concentration; Acid washing temperature; Acid washing flow rate; Start time of hot water disinfection; End time of hot water disinfection; Hot water disinfection temperature filter pressure difference Siemens PLC
UHT sidel Siemens Bergerais upper computer inlet steam pressure; Ice water pressure; Tower water pressure; Inlet pressure of steam generator; Steam generator outlet pressure; Is the outlet pressure of the material liquid (unable to provide point location) in progress? Siemens PLC
Aseptic water preparation: Siemens Bergerais upper computer sterile water flow rate; Sterilization time of sterile water; Sterilization temperature of sterile water; Sterile water outlet pressure; Aseptic water outlet temperature; Aseptic water tank; Ice water pressure; Tower water pressure; Is the steam pressure in progress (unable to provide point location)? Siemens PLC is in progress
Disinfectant operation and filling, Siemens Bergerais upper computer steam inlet pressure; Steam inlet pressure; Air pressure inlet pressure RO water pressure; Disinfection tank liquid level; PAA concentration; Reflux temperature; Disinfectant flow rate; Tower water pressure; Ice water pressure; Is the outlet pressure of the filter (unable to provide a point) in progress? Siemens PLC
The start time of water washing for the sterile system of the production line and the CIP filling of Siemens Bergerais upper computer; End time of water washing; Washing flow rate; Washing temperature; Start time of alkaline washing; End time of alkaline washing; Alkali washing concentration; Alkali washing temperature; Alkali washing flow rate; Start time of acid washing; End time of acid washing; Acid washing concentration; Acid washing temperature; Acid washing flow rate; Start time of steam washing; End time of steam washing; Steam washing temperature; Start time of softening water; End time of softened water; Softened water temperature; Softened water flow rate; Start time of purified water; End time of purified water; Is the purified water temperature (unable to provide location) in progress? Siemens PLC
Start time of production line COP/SOP cleaning and disinfection operation and filling of alkaline foam on the Siemens Becala upper computer; Alkaline foam end time; Alkaline foam concentration; Start time of softening water; End time of softened water; Softened water temperature; Acid foam start time; Acid foam end time; Acid foam concentration; SOP (PAA) start time; SOP (PAA) end time; SOP (PAA) concentration; SOP (PAA) temperature; SOP (PAA) traffic; Alkali concentration; Alkali temperature; Alkali flow rate; Alkali start time; Is the end time of alkali (unable to provide location) in progress? Siemens PLC
Pre blow molding angle of the upper computer of the blow molding machine Xidele Siemens Beijilai; Pre blow molding pressure; Complete blow molding angle; Complete blow molding pressure; Complete the maximum pressure deviation for blow molding; Stretching rod returns; Pressure relief begins; The valve has been blown and closed; Furnace temperature setting; Actual furnace temperature; Furnace temperature output (%); Start operating variables for furnace temperature; Furnace temperature bypass operation variable; Release the furnace temperature plastic bottle stopper; Is the sterilization nozzle functioning properly; Sterilization spray flow rate; Plastic preform temperature setting; Actual temperature of plastic embryo; Plastic embryo temperature output; Maximum deviation of plastic embryo temperature; The temperature of the plastic embryo begins to operate as a variable; Plastic preform temperature bypass operation variable; Air recovery set value; Actual value of air recovery; Air recovery output; Duration of recycling and reuse; The longest time for recycling and reuse; Lamp power; Is the light tube turned on (unable to provide location)? Siemens PLC is currently in progress
The hourly output of the Siemens B&R upper computer of the filling machine Xidele; Filling speed; Ring cylinder liquid level; Filling ring cylinder pressure; Positive pressure in the filling and capping area; Positive pressure in sterile water area; Positive pressure in disinfection area; Pressure difference between filling rooms; Washing pressure of bottle washing machine; Shielding temperature on the distributor; Shielding temperature under the distributor; Filling temperature; Bottle mouth flushing pressure; Bottle cap sterilization temperature; Bottle cap sterilization flow channel 1; Bottle cap sterilization flow channel 2; Bottle cap sterilization flow channel 3; Is the temperature for drying sterile air (unable to provide location) in progress for Siemens PLC
Spiral cap inspection machine, Siemens Bergerais upper computer high cap; Crooked lid; Roll cover; No abnormal cover; The anti-theft ring connection bridge is broken; Squeezing total; Empty bottle; Low liquid level; High liquid level; Squeezing; total; No code; Duplicate code; Spray code offset; Incomplete; Total No (unable to provide location) in progress Siemens PLC
water treatment Zhejiang Songtai 1. Siemens 1 # sand filter inlet pressure (standard value 0.2-0.4MPa); 1 # Carbon filter inlet water pressure (standard value 0.1-0.3MPa); 2 # Sand filter inlet pressure (standard value 0.2-0.4MPa); 2 # Carbon filter inlet water pressure (standard value 0.1-0.3MPa); Raw water conductivity (standard value ≤ 300 μ m/cm); Pure water conductivity (standard value ≤ 6.3 μ m/cm); Pure water pH (standard value 5.5-7.5); Primary inlet pressure (standard value 0.5-1.2MPa); Primary concentrated water pressure (standard value 0.4-1.0MPa); Secondary inlet pressure (standard value 0.5-1.2MPa); Secondary concentrated water pressure (standard value 0.4-1.0MPa); Precision filter 5 μ m inlet pressure (standard value 0.15-0.4MPa); Precision filter 1 μ m inlet pressure (standard value 0.15-0.4MPa); Primary RO effluent flow rate m ³/h; Primary RO concentrated water flow rate m ³/h; Secondary RO effluent flow rate m ³/h; The flow rate of the second level RO concentrated water, m ³/h, cannot be collected: No (the supplier's points have been summarized and integrated into one PLC, and the docking has not been completed. It is expected to provide the points by the 25th). Siemens S7-1500 is currently in progress
Raw water conductivity (standard value ≤ 300 μ m/cm)
Need to transform Hardware to achieve:
Primary inlet pressure (standard value 0.5-1.2MPa); Primary concentrated water pressure (standard value 0.4-1.0MPa); Secondary inlet pressure (standard value 0.5-1.2MPa); Secondary concentrated water pressure (standard value 0.4-1.0MPa); Precision filter 5 μ m inlet pressure (standard value 0.15-0.4MPa)
Precision filter 1 μ m inlet pressure (standard value 0.15-0.4MPa)
Primary RO effluent flow rate m ³/h
Pre processing CIP center Zhejiang Songtai Siemens water washing start and end time; Starting and ending time of alkaline washing; Alkali washing flow rate; Alkali washing concentration; Alkali washing temperature; Start and end time of intermediate water washing; Start and end time of acid washing; Acid washing flow rate; Acid washing concentration; Acid washing temperature; Final flushing start and end time; Siemens S7-1500 in progress
Sand and carbon cylinder Zhejiang Songtai Siemens recoil start and end time; Start and end time of positive impact; Disinfectant; Disinfection concentration; Disinfection start and end time; Start and end time of steam disinfection; Steam temperature; Final washing and rinsing time for both sides; Siemens S7-1500 in progress
Start and end time of Siemens water washing for first and second stage RO membranes in Zhejiang Songtai; Starting and ending time of alkaline washing; Alkali washing flow rate; Alkali washing concentration; Alkali washing temperature; Start and end time of intermediate water washing; Start and end time of acid washing; Acid washing flow rate; Acid washing concentration; Acid washing temperature; Final flushing start and end time; Alkali washing flow rate; Alkali washing concentration; Alkali washing temperature; Acid washing flow rate; Acid washing concentration; The pickling temperature is in progress for Siemens S7-1500
Is the ice water machine Siemens (requires installation of 485 to WiFi communication) in progress? Siemens PLC
High voltage machine Siemens or not (requires installation of 485 to wifi communication) in progress Siemens PLC(
Low voltage machine Siemens or not (requires installation of 485 to wifi communication) in progress Siemens PLC
The water, electricity, and gas instruments are connected to the human module, and the instrument reading communication module has been purchased and is currently in progress. It is a 485 to WiFi communication box