As a professional provider of IoT data acquisition solutions and an expert in industrial IoT data acquisition, the editor of Shanghai Data Acquisition IOT Technology Co., Ltd, (daq-iot) hereby presents the following introduction, and sincerely welcomes discussions and exchanges.
Supported Communication Interfaces: CAN, RS485, Mbus, 4–20mA, Profibus, CC-Link, HART, digital I/O, etc.
Industrial Protocols: Modbus RTU/TCP, HJ212, IEC104, DLT645, DLMS, IEC61850, MQTT, etc.
Mail:export@daq-iot.com
Constructing an unmanned Remote Monitoring system, which willPV power stationAll information is uploaded via fiber optic to the centralized control center of IoT Smart Energy Co., Ltd. Each site must be equipped with sufficientData Acquisitiondevices, and the data provided to the remote control system includes but is not limited to:Integrated Automation SystemInverter, box transformer measurement and controlelectricity meterWaiting for device information to achieve data aggregation. The collection device supports Modbus RTU/TCP, CDTIEC101/102/103/104、 DLT645 and other communication Protocol, as well as providing RS485, Ethernet and other related communication interfaces. The station Data Acquisition forwarding device should be configured separatelyCommunication management device, TheZhihuforwarding device provides wireless communication such as 4G/5G and WIFI, as well as Ethernet and RS485 interfaces, which can provide data interfaces for remote centralized control systems. It supports docking with remote centralized control side collection devices or databases through Modbus TCP, IEC104, and other methods such as calling theProtocolhistorical database API interface to achieve data uploading or writing to theReal-timehistorical database. Equipped with remote start stop control for inverters, supporting remote adjustment of active and reactive power.
All communication network equipment involved must be selected from domestic devices, and the operating system must use domestic operating systems such as UNIX. The system must be patched for vulnerabilities and reinforced, and a reinforcement report must be provided. Configure electromagnetic protection cabinets and construct redundant communication channels. The security protection work of the power monitoring system should implement the national information security level protection system, adhere to the relevant requirements of national information security level protection, and insist on "security zoning, network dedicated, horizontal isolationVertical authentication”The principle is to ensure the safety of the power monitoring system and pass the evaluation of relevant qualified units. The power grid dispatch data network, comprehensive management network, communication system equipment, and installation deployment must be carried out in accordance with the relevant requirements of the local power grid.
AGC、AVC、 Some configuration requirements for data network communication equipment shall be approved by the power grid company for system access (plan)

PV Platform demo account:http://energy.daq-iot.com/peaks/charts Account: shucai

Remote telemetry, remote signaling, remote control, and remote adjustment
Power on time system lockout status, full network power on control, active power regulation (actual value)
Shutdown time inverter on/off status full Gateway machine control reactive power regulation (actual value)
PV input voltage DI status full network power on/off control active power regulation (percentage)
PV input current active scheduling command abnormal PV shutdown reactive power regulation (power factor)
Abnormal DC input power reactive power dispatch command PV startup
Voltage and power regulation mode of power grid AB line
Active voltage regulation status of power grid BC line
Voltage and reactive power regulation status of power grid CA line
Active power control method for phase A voltage in the power grid
Identification of phase B voltage fault in the power grid
Abnormal identification of phase C voltage in the power grid
Abnormal cube of phase A current in the power grid
Address conflict of phase B current equipment in the power grid
Fault of C-phase current lightning arrester in power grid
Active power supply failure
Reactive power communication failure
Power factor license expires
Rated power main circuit breaker disconnected
Number of power grid frequency alarms
Inverter efficiency with high string voltage
Internal temperature DC arc fault
Accumulated power generation in reverse series connection
DC input total power group backflow
The current power generation statistics time string shows abnormal power
Current hourly power generation AFCI self-test failed
Short circuit of power grid phase line to PE for daily electricity generation
The power generation for the week was affected by a power outage in the grid
Undervoltage of power generation in the current month's power grid
Overvoltage of the power generation grid in the past
The previous day's electricity statistics showed that the grid voltage was unbalanced
The previous day's power generation exceeded the frequency limit of the power grid
The previous week's electricity statistics showed that the power grid was under frequency
The power generation in the previous week resulted in unstable grid frequency
The previous month's electricity statistics time output overcurrent
The DC component of the output current of the previous month's generated electricity was too large
Abnormal residual current in the previous year's electricity statistics time
Abnormal grounding of the power generation system in the previous year
Low insulation impedance for carbon dioxide emission reduction
The total voltage temperature of the busbar is too high
The maximum value of PV voltage is abnormal for the equipment
Upgrade of minimum PV voltage failed
PV negative to ground voltage average monitoring unit fault
PV ground voltage maximum value power collector fault
PV negative to ground voltage minimum value active islanding
Passive islanding with maximum active power regulation
Minimum instantaneous AC overvoltage for active power regulation
Maximum reactive power regulation, external device port short circuit
Reactive power regulation minimum value off grid output overload
Abnormal configuration of insulation impedance value battery board
Device SN standby
grid-connected
Normal grid connection
Power rationing and grid connection reduction
Self rated grid connection
Normal shutdown
Power restriction shutdown
inspection
Optimizer malfunction
The built-in PID is working abnormally
Input string to ground voltage high
Abnormal external fan
Off grid controller abnormality
String loss