Fitting an activation energy from two rate measurements is a common engineering task and a reliable source of silent bugs. The algebra is short, but two decisions dominate the result: taking the natural log before subtracting, and keeping the gas constant and the activation energy in compatible energy units. A third problem arrives after the arithmetic — the number is only as trustworthy as the temperature range behind it.
Deriving the two-point form
The Arrhenius equation relates a rate constant to temperature:
k = A * exp(-Ea / (R * T))
T is absolute temperature in kelvin, R is the gas constant, and Ea is activation energy per mole. Taking ln of both sides makes it linear in 1/T:
ln(k) = ln(A) - (Ea / R) * (1/T)
Write that at two temperatures and subtract, eliminating the unknown pre-exponential factor A:
ln(k2/k1) = -(Ea/R) * (1/T2 - 1/T1)
= (Ea/R) * (1/T1 - 1/T2)
Ea = R * ln(k2/k1) / (1/T1 - 1/T2)
The sign check is useful in code: if k rises with temperature (k2 > k1 at T2 > T1), then both ln(k2/k1) and 1/T1 - 1/T2 are positive, so Ea is positive. A negative result means the temperatures were swapped or the rate ratio was inverted.
const R = 8.31446261815324; // J/(mol*K)
const twoPointEa = (k1, T1, k2, T2) =>
R * Math.log(k2 / k1) / (1 / T1 - 1 / T2); // J/mol
Worked example
Suppose a rate doubles from 300 K to 310 K: k1 = 0.010 s⁻¹, k2 = 0.020 s⁻¹.
ln(k2/k1) = ln(2) ≈ 0.693147
1/300 - 1/310 = 0.00333333 - 0.00322581 ≈ 0.000107527 K⁻¹
Ea = 8.31446 * 0.693147 / 0.000107527
≈ 53597 J/mol = 53.60 kJ/mol
Using R = 0.00831446 kJ/(mol·K) with the same inputs gives 53.60 kJ/mol directly. What breaks is mixing them: dividing by 1000 only at the end is fine, but replacing R with 0.008314 and then reporting the result in J/mol produces a number 1000 times too small.
Extrapolation is the other hazard. Extending the fitted Ea from 310 K to 320 K predicts:
k(320)/k(300) = exp(-(Ea/R) * (1/320 - 1/300)) ≈ 3.83
That is a large claim from two measurements ten kelvin apart, and it assumes a single constant Ea over the whole interval.
Boundary conditions
- Temperatures must be kelvin. Substituting Celsius in the reciprocal terms is a common and often plausible-looking error.
-
ln, notlog10. If you use base-10 logs, multiply byln(10)≈ 2.302585. - R is per mole. If Ea is expressed per molecule, use the Boltzmann constant instead.
- k1 == k2 makes the log zero and implies Ea = 0; T1 == T2 divides by zero. Validate both.
- Two points cannot detect curvature. A changing mechanism, phase transition, catalyst deactivation, or diffusion limit means Ea is not constant over the range.
- The derived Ea is an effective parameter valid only over the measured interval, not a universal material constant.
For a calculation that shows the units alongside the result, try the Arrhenius equation calculator. The Arrhenius equation guide covers the linearization and where two-point estimates stop being reliable.