DEV Community

Cover image for Closed-Loop Bionic Vision: 96-Electrode Human Trial Results
Shawdai Marie
Shawdai Marie

Posted on

Closed-Loop Bionic Vision: 96-Electrode Human Trial Results

Researchers affiliated with ETH Zurich, UC Santa Barbara, and Miguel Hernández University studied one participant temporarily implanted with a 96-electrode visual cortex array. They trained a deep neural network to predict electrically evoked neural activity using pre-stimulation brain activity and stimulation parameters. In this proof of concept, model-selected stimulation more accurately evoked targeted neural activity while using less electrical current. Whether the approach improves safety or generalizes to other patients remains open.

Individual Post Research Log • ID: RL-2026-1115-D3-LI3 • Logged: 2026-11-16

Scope & Ethics: Reports exact 96-electrode proof-of-concept metrics in one participant.

Ref: Liu, Soo, López-Peco & Soto-Sánchez (2026, Neuron); Mendes (2026, EBRAINS).

https://doi.org/10.1016/j.neuron.2026.07.006

https://ebrains.eu/news-and-events/2026/researchers-simulate-novel-brain-architecture-for-fast-and-flexible-decision