I Made a Battery Admit It Was Only 73% Healthy — On-Device, End to End

Voltage lies.

Put a battery under load and its terminal voltage sags. Let it rest and the voltage springs back. A naive fuel gauge watching only voltage will happily tell you a worn-out cell is "fine" right up until it falls off a cliff. The number you actually care about — is this battery still good, or is it time to replace it? — isn't in the instantaneous voltage at all. It's in the capacity: how much charge the cell can still deliver between full and empty.

That quantity fades as a cell ages. Tracking it is called State of Health (SoH), and it's the difference between "the device says 80%" and "the device has 80% of the runtime it had when it was new."

I wanted my open-source battery SDK (ibattery-sdk, Apache-2.0) to learn SoH on the device itself — no cloud model, no floating-point, on MCUs with kilobytes of RAM. This post is the story of getting that working end to end: from a coulomb integral in firmware to a faded value showing up live on a Grafana dashboard.

The idea: learn capacity from one full→empty trip

You don't need a PhD-grade model to estimate usable capacity. You need two anchors and an ammeter.

  • Full anchor — when the cell is at its full-voltage plateau, declare "this is full" and set the coulomb counter to the rated capacity.
  • Discharge — integrate current over time (coulomb counting). Every milliamp-hour that leaves the cell ticks the counter down.
  • Empty anchor — when the cell hits its empty-voltage threshold, look at how much charge actually flowed. A healthy cell delivers close to its rated capacity before going empty. An aged cell hits empty early — it simply has less to give.

From the charge measured between those two anchors, you get the cell's real usable capacity, and SoH = measured / rated. The SDK runs it through an integer EMA (so one noisy excursion doesn't whip the estimate around) and a plausibility guard (reject anything outside 30–120% of rated — that's almost certainly a glitch, not a real measurement).

The whole thing is integer-only, ~200 bytes of flash, and zero new static RAM. It's opt-in behind a Kconfig flag and rides on the coulomb counter that was already there.

That's the theory. The fun part is proving it on hardware.

You can't wait six months for a coin cell to age

Here's the catch with validating a capacity-fade feature: capacity fade takes months. I was not going to babysit a coin cell through a hundred discharge cycles to get a number on a chart.

So I cheated — honestly. I used a Nordic PPK2 (Power Profiler Kit II) as a programmable cell emulator. In Source Meter mode it's a voltage source you can sweep from ~0.8 V to 5 V while it measures current. That means I can drive the sensed battery voltage anywhere I want, independently of the MCU's own supply, and walk it through a full→empty excursion in minutes instead of months.

The rig (all on a breadboard):

  • PPK2 sources the emulated cell voltage.
  • A resistor divider taps that voltage down onto an ADC pin (the firmware has an external-ADC voltage-sense mode for exactly this).
  • An INA219 current sensor in the load path measures the real current flowing through a load resistor — that's what feeds coulomb counting.
  • Everything shares a common ground (the ADC measures relative to it — skip this and you get garbage).

One nice detail: the divider tap sits before the INA219 shunt, so the ~microamps the divider draws never pollute the current reading.

The bring-up gotchas (because there are always gotchas)

The divider reads low. My 10 kΩ/10 kΩ divider plus ADC gain came in about 9% under the true voltage. That doesn't matter for SoH — SoH is charge-based, not voltage-based — but it does matter for the anchors, which are voltage thresholds. To make the firmware read ≥ 2950 mV (the full-anchor threshold), I had to set the PPK2 to ~3300 mV. Measure, don't assume.

Make the excursion fast. At the default rated capacity, draining at ~33 mA would take hours. I rebuilt with a small rated-capacity override so a full excursion finishes in a few minutes — same physics, faster clock.

Cross-check your instruments. The PPK2's own ammeter read 31.9 mA while the INA219 reported 31.7 mA — agreement under 1%. When two independent measurements agree, you trust the chain.

Watching it happen

With the full anchor armed (SOH = 100%), I let it discharge, then swept the PPK2 down toward empty. The serial stream tells the whole story:

V=2890 mV  I=22.4 mA  Q=5.39 mAh  SOH=100.00%
V=2623 mV             Q=5.38 mAh  SOH=100.00%
V=2351 mV             Q=5.37 mAh  SOH=100.00%
V=2079 mV  PWR=4      Q=0.01 mAh  SOH=73.10%   ← empty anchor fires
>>> SOH CHANGED 100.00% -> 73.10% <<<
Enter fullscreen mode Exit fullscreen mode

There it is. The moment the reading crossed into the empty region, the empty anchor fired, the coulomb counter snapped to zero (nothing left), and the SDK locked in a learned State of Health of 73.10% — a plausible, faded value, computed entirely on a Cortex-M4 with integer math.

From firmware to a live dashboard

A number in a serial log is satisfying. A number on a dashboard is convincing.

The SoH value rides out over BLE in the telemetry packet (a dedicated wire-format field), into a Python gateway, into InfluxDB, and onto a Grafana panel. I confirmed it landed in the database directly:

_field: soh_pct   _measurement: battery_telemetry   _value: 73.1
Enter fullscreen mode Exit fullscreen mode

And on the dashboard, the State of Health gauge dropped from 100% to 73.1%, with the trend graph capturing the exact step down. (Screenshot above.) That's the whole pipeline — firmware → BLE → gateway → time-series DB → dashboard — carrying a value the device figured out about itself.

The part that makes it real: it survives a reboot

A learned value you lose on power-cycle is a parlor trick. So the SDK persists the learned capacity to flash (Zephyr NVS), behind a guard that rejects the stored value if the configured rated capacity has changed.

I reset the board and watched the first telemetry line after boot:

Battery SDK initialized OK
[v4 t=32]  V=1872 mV  SOH=73.10%   ← restored from flash, not 100%
Enter fullscreen mode Exit fullscreen mode

It came up reading 73.10%, straight from flash — not re-initialized to 100%. Learn it once, keep it forever (or until the next excursion refines it).

Why this matters

Knowing which devices in a deployment are genuinely wearing out — versus just momentarily sagging under load — is the foundation for sensible battery-replacement decisions. Doing that estimation on-device, in a couple hundred bytes of integer code, means it works on the cheapest sensor node without a cloud round-trip.

It's all open source and runs today on nRF52840, STM32L4, and ESP32-C3 (Zephyr RTOS):

👉 github.com/aliaksandr-liapin/ibattery-sdk

If you're building battery-powered hardware and want a fuel gauge that tells you the truth about aging — not just the moment-to-moment voltage — take it for a spin. Issues and PRs welcome.


Built and validated with a NUCLEO-L476RG, an X-NUCLEO BLE shield, an INA219, and a PPK2 standing in for a cell. The voltage readings are emulated; the coulomb counting, the SoH math, the persistence, and the dashboard are all real.