Two waveguide switches with identical electrical data, same band, same isolation — one sits in a system at VSWR 1.08, the other at 1.25. Nothing in the datasheet explains it. In most cases the difference is the flange.
The four flange families you will actually meet
UG (UG-385/U, UG-387/U and so on) — the classic MIL-spec flat flange with a defined bolt circle. Two UG flanges mate with a gasket or an O-ring in a groove, depending on the variant. Widely used in military and legacy radar hardware.
CPR (CPR-90G, CPR-112G…) — "Cover, Pressurise, Rectangular". A flat cover flange with a gasket groove, designed so the joint can be pressurised. The letter suffix matters: G is grooved, F is flat, R is a choke flange. A CPR-G must mate with another CPR-G with a gasket. Bolting a CPR-G to a flat UG works mechanically and leaks electrically.
PDR — the smaller, lighter pressurisable family used in some European and telecom systems. Same rule: grooved to grooved.
Choke flanges — a quarter-wave choke groove replaces the need for intimate metal-to-metal contact. Choke flanges tolerate slightly imperfect alignment and are more forgiving at high power, but a choke flange must mate with a flat flange, never with another choke.
The mismatch nobody notices until it is a problem
The failure mode is quiet. A grooved flange bolted to a flat flange has a small air gap at the gasket land, which is a discontinuity right at the waveguide junction. At low frequency it shows as a fraction of a dB. At WR28 and WR42 it shows as 0.3 to 0.5 dB of insertion loss and a VSWR bump that moves when you loosen and retighten the bolts.
There is a second, worse version: two flanges with different bolt circles "made to fit" by drilling. That is a permanent invitation to leakage and to arcing at high power.
What to check before ordering a switch
- Flange type and suffix on both sides. If a switch is specified CPR-90G, both ports are grooved, and both mating flanges in your system must be grooved, with gaskets.
- Bolt circle and bolt count. WR90 UG-39/U and CPR-90G share a bolt pattern; WR75 UG-419/U and CPR-75G do not always.
- Gasket or O-ring. Grooved flanges need the right seal. A missing gasket is a leak, and on a pressurised run it is a continuous leak that the compressor will chase forever.
- Whether the switch is expected to hold pressure. Not every waveguide switch body is rated for a pressurised line. If the system runs dry air or nitrogen at positive pressure, confirm the seal construction and whether the shaft seal is dynamic-rated.
Pressurisation, briefly
The reason to pressurise is not dust. Dry gas raises the breakdown voltage of the gap inside the waveguide, so the same cross-section carries more peak power, and continuous positive pressure keeps humid air out so condensation cannot form on the walls. Both effects matter at high power; the moisture effect matters even at moderate power in outdoor installations.
The consequence for switch selection: if the run is pressurised, the switch is part of the pressure boundary. A switch whose sealing face separates briefly during actuation will vent the line every time it changes state. Some designs handle this with a make-before-break seal arrangement; others do not, and the system needs make-up gas capacity to compensate.
A practical checklist for matching a switch to an existing run
Measure the mating flange you already have: bolt circle diameter, bolt count and thread, whether there is a gasket groove, and the depth of that groove. Then order the switch to that, rather than ordering the switch and adapting afterwards. Adapters cost more than the correct flange option, and every adapter adds two more junctions to a run that was supposed to be a single waveguide section.
For high power work, also confirm power rating at the pressure and altitude the system actually operates at. A rating quoted at sea level with dry air is not the rating at 3000 m.
DB Design (MeiXun Wuxi) builds waveguide switches from WR28 to WR284 in manual, motorised and latching versions, with CPR, UG and PDR flange options matched to the mating hardware. More on the range at dbdesignmw.com.