Why Your Smart Switch Won't Turn Off: LED Inrush Current and Welded Relay Contacts

Written from a luminaire manufacturer's bench. Fair warning: this is not a product pitch — it is what you learn testing lamps and switches on the same circuit for a living.

When 'Off' Isn't Off

You tap Off in the app. The app confirms it is off. You hear the click on the wall. The lamp stays on.

The cost of a wrong switch is not the money — it is the rework, the tripped breaker, and the lamp you cannot switch off at 1 a.m. One blog put it better: a nineteenth-century mechanical switch on a twenty-first-century solid-state load.

[Figure: relay contact welded by LED inrush]

First, Separate Three Kinds of 'Won't Turn Off'

Do not rush to call the switch counterfeit. 'Won't turn off' is at least three different faults.

  1. Smart-bulb always-on plus gateway logic. Tapping Off only sends the bulb into standby; the switch never cut power, so it changes back later.
  2. Single-live-wire ghost glow. The lamp glows faintly after switch-off — leakage current the switch steals through the lamp, not full brightness.
  3. Welded relay contacts. The coil moves, the click is normal, but the lamp is at full brightness and will not go off — an irreversible physical weld.

Only the third matters here, and it is the fault most often mistaken for a software bug: you reinstall the app and re-pair the network all night while the contacts welded hours ago.

[Figure: three causes vs. cold-start peak current]

Why a Smaller Lamp Is More Likely to Kill the Switch

Every LED lamp contains a rectifier bridge and a large filter capacitor. At power-on the capacitor is empty, so to the mains it looks almost like a short circuit, and cold-start inrush pours in — 20 to 100 times the steady-state value, lasting only a few hundred microseconds to a few milliseconds.

A single 10 W LED lamp, in that first millisecond of closing, is equivalent to a 1000 W load sitting on the contacts.

Measured: ten 20 W LED lamps draw about 0.9 A steady-state; the cold-start peak is 31 A, decaying to 2.1 A after roughly 1.5 ms. The relay contact is rated for 10 A. Thirty-one amps onto ten — of course something gives.

Capacitive loads are sized for 5 to 10 times the steady-state current, or higher. Counter-intuitively, the smaller and more numerous the lamps, the more each driver delivers its own inrush while one contact does the switching — a heap of small lamps on one circuit is the most dangerous case.

How the Weld Happens: Three Actions, a Few Hundred Microseconds

Too fast for the eye to follow. Slow it down.

  1. The capacitor looks close to a short, inrush rushes in, and current density piles up on the contact.
  2. The relay armature snaps closed, but metal is elastic, so the contacts bounce and open a tiny gap within milliseconds.
  3. Voltage breaks down that gap and draws an arc, locally thousands of degrees, melting the silver-alloy plating. The bounce stops, and the two contacts are glued together by molten metal the return spring cannot pull apart.

Traditional wall switches rarely do this: bigger contacts, stiffer springs, so a micro-weld is flung apart. A smart switch must fit an antenna, chip and power supply in one box, so it uses a miniature pulse relay — small contacts, weak spring. Inrush it survives, you cannot.

[Figure: three actions that weld a contact]

Match the Solution to the Load

Choosing a switch comes down to how it switches off.

Type How it switches off Inrush tolerance Good for Watch out for
Mechanical relay Small relay makes and breaks Weak; capacitive loads need heavy derating Ceiling lights, strips, circuits with margin Small lamps, many circuits, frequent switching — welds first
Zero-cross detection Closes only at the zero crossing Strong; kills the arc by principle High power, many circuits, commercial panels Datasheet only — ask support
Triac dimming Phase chopping, no contacts Medium Rooms needing smooth dimming Needs a dimmable driver; cheap units flicker low; small downlights glow
Solid-state relay Fully solid-state, no contacts Strong; no wear Frequent switching, automation-heavy circuits Small leakage; an ordinary LED may glow when off

A headline rating like 400 W / 10 A is quoted for incandescent lamps — a resistive load. Your LED is capacitive.

[Figure: four switch types and their pitfalls]

Already Welded? Diagnose It, Then Deal With It

Step 1. Send Off from the app and listen for the click: the coil moves, control works, yet the lamp does not budge — that is welding.

Step 2. Pull the main breaker, wait a few minutes, close it. Lamp still on means software and automation are ruled out.

Step 3. Measure the normally-open contact with a multimeter in continuity mode. Conducting while idle confirms the weld.

Emergency: a gentle tap on the housing sometimes shakes a micro-weld loose, but the contact is already pitted and will weld again next power-up. Temporary only.

The real fix is replacing the switch: establish the circuit's load type (resistive or capacitive LED) and lamp count, size by the derated figure, and prefer models labeled zero-cross switching, high inrush, or lamp load.

Three Checks Before You Buy

  1. Do the load math. Back the circuit's total LED wattage out with a 5 to 10 times inrush margin to see what contact capacity the switch needs. Many small lamps on one circuit is the easiest trap.
  2. Ask support. Zero-cross switching? Contact material? AgSnO₂ silver tin oxide resists high-temperature arcs better than ordinary silver cadmium. Any rated capacitive or LED load capability? If they cannot answer, do not order.
  3. Check material and installation. With no neutral you are stuck with single-live-wire — watch for ghost glow, and do not cram a heap of small lamps onto one circuit.

Someone who really hit this swapped a 10 A ordinary intermediate relay for a higher-inrush type with 25 A contact capacity and a wider gap, then added an NTC inrush limiter at the driver input. Cold-start current fell from 31 A to around 15 A, and 1000 consecutive power-ups produced no re-weld.

The lamp stays on — did I buy a fake switch?

No — it is the wrong load class. Relay makers treat this as the expected result of sizing without derating.

Will a more expensive, fancier smart switch fix it?

Only if it has zero-cross detection and high-inrush contact material, not because of price. An expensive one without zero-cross welds the same.

Can I just use smart bulbs and keep the wall switch permanently on?

It works, but the lamps stay online, so you need a local button or wireless switch when the network drops — and watch for leakage and heat.

Wrapping Up

Lamp makers and switch makers sit on the same circuit. Look at the lamp and the switch parameters together.