Pilz PNOZ s4 vs PNOZ X3: Safety Relay Wiring Schemes & E-Stop Architecture
Functional machine guarding requires fail-safe evaluation of emergency stop pushbuttons, safety gates, and optical light curtains. Pilz PNOZ safety relays set the global benchmark for Category 4 / PLe (ISO 13849-1) and SIL 3 (IEC 62061) compliant emergency stop circuits.
1. Comparing PNOZcompact (s4) with Classic PNOZ (X3)
| Specification | Pilz PNOZ s4 (750104 / 751104) | Pilz PNOZ X3 (774310 / 774318) |
|---|---|---|
| Housing Width | Ultra-slim 22.5 mm | Standard 45.0 mm |
| Safety Contacts | 3 N/O instantaneous + 1 N/C auxiliary | 3 N/O safety + 1 N/C auxiliary + 1 Semiconductor |
| Supply Voltage | 24 VDC (Electronic power regulation) | 24 VDC / 110-230 VAC multi-voltage options |
| Terminals | Push-in spring or screw terminals | Screw terminals |
| Operating Modes | E-stop, safety gate, light curtain (OSSD) | E-stop, safety gate (Monitored or automatic start) |
Explore safety hardware and contactors on the AOCTRL Pilz Safety Catalog and AOCTRL Safety Automation Hub.
2. Dual-Channel E-Stop Wiring with Cross-Fault Detection
To achieve Category 4 architecture:
- Wire dual N/C contacts across terminals
S11-S12(Channel 1) andS21-S22(Channel 2). - The relay outputs pulsed test signals on
S11andS21. A short circuit between channels is instantly detected, dropping safety output contacts13-14,23-24, and33-34. - Wire feedback loop from downstream contactors into
Y1-Y2(PNOZ s4) orS33-S34(PNOZ X3) for contact weld monitoring.