Free engineering calculators for substation automation, protection & control and transmission engineers. Every tool shows its formula and standard reference (IEEE/ANSI, IEC).

Joined Joined on 
Scaling a 4–20 mA Loop Without the Offset Mistakes

Scaling a 4–20 mA Loop Without the Offset Mistakes

Comments
3 min read
Induction Motor Starting: Why Locked-Rotor Current Is High, and What Torque You Actually Get

Induction Motor Starting: Why Locked-Rotor Current Is High, and What Torque You Actually Get

Comments
3 min read
Ohm's Law, Worked Out: What 12 V and 2 A Tell You About a Load

Ohm's Law, Worked Out: What 12 V and 2 A Tell You About a Load

Comments
4 min read
Voltage Drop: Why the Percent Matters More Than the Volts

Voltage Drop: Why the Percent Matters More Than the Volts

Comments
2 min read
Grounding Conductor Sizing: The Table Is a Floor, Not the Whole Answer

Grounding Conductor Sizing: The Table Is a Floor, Not the Whole Answer

Comments
4 min read
Reflections on a Transmission Line: Why an Open Far End Sees Double Voltage

Reflections on a Transmission Line: Why an Open Far End Sees Double Voltage

Comments
4 min read
Power Swings: Why a Distance Relay Cannot Just Trip on What It Sees

Power Swings: Why a Distance Relay Cannot Just Trip on What It Sees

Comments
3 min read
Ring Bus, Explained Simply: What Opening Two Breakers Does to a Substation Bus

Ring Bus, Explained Simply: What Opening Two Breakers Does to a Substation Bus

Comments
4 min read
Short Line, Medium Line, Long Line: When the Simple Transmission Model Stops Working

Short Line, Medium Line, Long Line: When the Simple Transmission Model Stops Working

Comments
4 min read
Load Flow Without the Software: Reading a Bus Voltage Table

Load Flow Without the Software: Reading a Bus Voltage Table

Comments
4 min read
From AWG to mm2: Wire Sizes Without the Conversion Errors

From AWG to mm2: Wire Sizes Without the Conversion Errors

Comments
2 min read
Unbalanced Three-Phase Loads: Why the Neutral Carries Current

Unbalanced Three-Phase Loads: Why the Neutral Carries Current

Comments
4 min read
Cable Ampacity: Why the Table Value Is Only the Starting Point

Cable Ampacity: Why the Table Value Is Only the Starting Point

Comments
5 min read
Motor Starting Voltage Dip: Why the Lights Flicker When a Big Motor Starts

Motor Starting Voltage Dip: Why the Lights Flicker When a Big Motor Starts

Comments
2 min read
Three-Phase Power: kW, kVA, and Why Power Factor Sits Between Them

Three-Phase Power: kW, kVA, and Why Power Factor Sits Between Them

Comments
2 min read
Distance Protection Zones: Why Zone 2 Waits

Distance Protection Zones: Why Zone 2 Waits

Comments
4 min read
Arc Flash Incident Energy: Why Working Distance Matters More Than the Label

Arc Flash Incident Energy: Why Working Distance Matters More Than the Label

Comments
4 min read
Power Factor Correction, Worked Out: 500 kW from 0.75 to 0.95 PF

Power Factor Correction, Worked Out: 500 kW from 0.75 to 0.95 PF

Comments
2 min read
Symmetrical Components in Plain English: Fortescue Without the Fog

Symmetrical Components in Plain English: Fortescue Without the Fog

Comments
3 min read
Grounding Conductor Sizing: What the Table Actually Assumes

Grounding Conductor Sizing: What the Table Actually Assumes

Comments
3 min read
Analog Scaling in SCADA: 4–20 mA to Engineering Units Without the Guesswork

Analog Scaling in SCADA: 4–20 mA to Engineering Units Without the Guesswork

Comments
4 min read
Per-Unit Without the Headache: Changing Base in Two Lines

Per-Unit Without the Headache: Changing Base in Two Lines

Comments
2 min read
Transformer Impedance and Fault Current: A Quick Worked Example

Transformer Impedance and Fault Current: A Quick Worked Example

Comments
3 min read
IDMT Relay Curves Explained: Picking the Right Curve for Feeder Protection

IDMT Relay Curves Explained: Picking the Right Curve for Feeder Protection

Comments
3 min read